GB/T 20386-2006 PDF in English
GB/T 20386-2006 (GB/T20386-2006, GBT 20386-2006, GBT20386-2006)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 20386-2006 | English | 95 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Textiles -- Determination of the content of ortho-phenylphenol
| Valid |
Standards related to (historical): GB/T 20386-2006
PDF Preview
GB/T 20386-2006: PDF in English (GBT 20386-2006) GB/T 20386-2006
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 59.080.01
W 04
Textiles - Determination of the Content of
Ortho-Phenylphenol
ISSUED ON: MAY 25, 2006
IMPLEMENTED ON: DECEMBER 01, 2006
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Principles ... 4
4 Reagents and Materials ... 5
5 Apparatus ... 6
6 Analytical Procedures ... 6
7 Calculation Result ... 9
8 Lower Limit of Detection, Recovery Rate and Precision ... 10
9 Test Report ... 10
Appendix A (Informative) Gas Chromatography – Mass Spectrometry Selective
Ion Chromatogram ... 12
Appendix B (Informative) Gas Chromatography – Mass Spectrometry
Chromatogram ... 13
Textiles – Determination of the Content of
Ortho-Phenylphenol
WARNING: Persons using this Standard shall have practical experience working
in formal laboratory. This Standard does not point out all possible safety issues.
Users shall assume the responsibility to take appropriate safety and health
measures, ensuring to meet the conditions stipulated by relevant national
regulations.
1 Scope
This Standard specifies the gas chromatography-mass selective detector (GC-MSD)
method for determining the content of ortho-phenylphenol (OPP) in textiles.
Method 1 in this Standard is applicable to the determination and confirmation of the
ortho-phenylphenol content in various textile materials and their products; Method 2 in
this Standard is applicable to determination and confirmation of the ortho-phenylphenol
and its salts and esters contents in various textile materials and their products.
2 Normative References
The provisions in following documents become the provisions of this Standard through
reference in this Standard. For dated references, the subsequent amendments
(excluding corrigendum) or revisions do not apply to this Standard, however, parties
who reach an agreement based on this Standard are encouraged to study if the latest
versions of these documents are applicable. For undated references, the latest edition
of the referenced document applies.
GB/T 6682 Water for Laboratory Use – Specifications (GB/T 6682-1992, neq ISO
3696:1987)
3 Principles
3.1 Method 1
The specimen is extracted by ultrasonic wave of methanol. After the extracting solution
is concentrated to a constant volume, it is measured by a gas chromatograph equipped
with a mass selective detector (GC-MSD). The selective ion detection is used for
6 months; while the mixed standard working solution is stored in the refrigerator at 0°C~4°C for
a valid period of 3 months.
5 Instruments and Apparatuses
5.1 Gas chromatograph: equipped with a mass selective detector (MSD)
5.2 Ultrasonic generator: working frequency of 40 kHz.
5.3 Centrifuge: 4000 r/min.
5.4 Rotary evaporator.
5.5 Anhydrous sodium sulfate column: 7.5 cm × 1.5 cm (inner diameter); containing
4cm of high anhydrous sodium sulfate.
5.6 Conical flask: with ground stopper, 100mL.
5.7 Centrifuge tube: with ground stopper, 15mL.
5.8 Concentration bottle: 100mL.
6 Analytical Procedures
6.1 Method 1
6.1.1 Extraction
Take a representative sample; shred it 5mm × 5mm below and mix well. Take 1.0g
(accurate to 0.01g) of the specimen; place it in a 100mL conical flask with a stopper;
add 50mL of methanol; and extract for 20min in an ultrasonic generator. Filter the
extracting solution. The residue is ultrasonically extracted by 30mL of methanol for
5min; combine the filtrate; and dehydrate by anhydrous sodium sulfate column; collect
in a 100mL concentration bottle; concentrate to near dryness in a 40°C water bath
rotary evaporator; dissolve by acetone and make constant volume of 5.0mL for
confirmation and determination of gas chromatography-mass spectrometry.
6.1.2 Determination
6.1.2.1 Gas chromatography-mass spectrometry conditions
Since the test results depend on the used instrument, it is impossible to give general
parameters for chromatographic analysis. The set parameters shall ensure that the
measured component may be effectively separated from other components during
chromatographic determination. The parameters given below prove to be feasible.
6.2.1 Extraction
Take a representative sample; cut it to a size of 5mm × 5 mm or less, and mix evenly.
Take 1.0g (accurate to 0.01g) of the sample; place it in a 100mL conical flask with a
stopper; add 50mL of methanol; and extract for 20min in the ultrasonic generator. Filter
the extracting solution in a 100mL concentrator bottle. The residue was ultrasonically
extracted by 30mL of methanol for 5min; combine the filtrate; then concentrate to near
dryness on a 40°C water bath rotary evaporator. Use 8mL of potassium carbonate
solution to dissolve the concentrated solution and totally transfer into a 15mL centrifuge
tube.
6.2.2 Acetylation
Add 1mL of acetic anhydride; shake for 2min. Accurately add 5.0mL of n-hexane;
shake for 2min; and centrifuge at 4000 r/min for 3min. Use a pointed pipette to extract
the lower aqueous phase. Add 10mL of sodium sulfate solution; shake for another 1min;
and centrifuge at 4000 r/min for 3min. The n-hexane phase is used for determination
and confirmation of gas chromatography-mass spectrometry.
6.2.3 Preparation of standard working solution
Accurately transfer a certain volume of standard solution of appropriate concentration
in a 15mL centrifuge tube; dilute to 8 mL by potassium carbonate solution. Add 1mL of
acetic anhydride; and follow the procedures in 6.2.2 then.
6.2.4 Determination
6.2.4.1 Gas chromatography-mass spectrometry conditions
Since the test results depend on the used instrument, it is impossible to give general
parameters for chromatographic analysis. The set parameters shall ensure that the
measured component may be effectively separated from other components during
chromatographic determination. The parameters given below prove to be feasible.
a) Chromatographic column: DB-17 MS 30m × 0.25mm × 0.1µm or equivalent;
b) Temperature of chromatographic column:
c) Inlet temperature: 270°C;
d) Chromatography-mass spectrometer interface temperature: 260°C;
e) Carrier gas: helium, purity ≥99.999%, 1.4 mL/min;
X - the content of ortho-phenylphenol in the sample, in mg/kg;
A - Peak area (or peak height) of ortho-phenylphenol or ortho-phenylphenol acetic
ester in the sample solution;
As - the peak area (or peak height) of ortho-phenylphenol or ortho-phenylphenol acetic
ester in the standard working solution;
c - the concentration of ortho-phenylphenol or equivalent ortho-phenylphenol in the
standard working solution, in mg/L;
V - volume of sample solution, in mL;
m - the amount of sample represented by the final sample solution, in g.
8 Lower Limit of Detection, Recovery Rate and
Precision
8.1 Lower limit of detection
The lower limit of detection for Method 1 is 0.10 mg/kg; while the lower limit of detection
for Method 2 is 0.05 mg/kg.
8.2 Recovery rate
The recovery rate of Method 1 and Method 2 is 85% ~ 110%.
8.3 Precision
In the same laboratory, the same operator uses the same equipment, the same test
method, and the same test object is tested independently in a short time. The absolute
difference between the two independent test results obtained by Method 1 and Method
2 shall be no greater than 10% of the arithmetic mean of the two measured values.
Provided that the value greater than 10% of the arithmetic mean of the two measured
values, it shall be on the premise of not exceeding 5%.
9 Test Report
The test report shall at least give the following contents:
a) Sample description;
b) The used standard;
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|