GB/T 15516-1995 PDF English
US$90.00 · In stock · Download in 9 secondsGB/T 15516-1995: Air quality - Determination of formaldehyde - Acetylacetone spectrophotometric method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB/T 15516-1995 | English | 90 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Air quality - Determination of formaldehyde - Acetylacetone spectrophotometric method
| |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 15516-1995
Similar standards HJ 870 HJ 799 HJ 759
GB/T 15516-1995: Air quality - Determination of formaldehyde - Acetylacetone spectrophotometric method ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT15516-1995
UDC 628.512.543.062
Z 15
GB
National Standard
of the People’s Republic of China
Air quality - Determination of formaldehyde -
Acetylacetone spectrophotometric method
Issued on. MARCH15, 1995
Implemented on. AUGUST 01, 1995
Issued by. National Environmental Protection Authority;
State Bureau of Technical Supervision.
Table of Contents
1 Subject content and application scope... 3
2 Principle... 3
3 Reagents... 4
4 Instruments... 6
5 Samples... 7
6 Steps... 8
7 Results and expression... 9
8 Precautions... 10
Additional Note... 11
Air quality - Determination of formaldehyde –
Acetylacetone spectrophotometric method
1 Subject content and application scope
1.1 Subject content
This Standard specifies the acetylacetone spectrophotometric method to measure
formaldehyde in industrial emissions and ambient air.
1.2 Application scope
1.2.1 This Standard applies to emissions in those industries such as resin
manufacturing, coatings, rayon, plastics, rubber, dye, pharmaceutical, plaint, and
tanning. And it also applies to determination of formaldehyde vapor produced when
conducting pharmaceutical disinfection, corrosion, and fumigation.
1.2.2 When the sampling volume is 0.5~10.0 L, the measuring range is 0.5~800
mg/m3.
1.2.3 When formaldehyde concentration is 20 µg/10 ml, coexist 8g of phenol (400
times), 10mg of acetaldehyde (500 times), 600mg of ammonium ion (30000 times)
without interference; coexist SO2, less than 20 µg, NO2 is less than 50 µg, the
recovery of formaldehyde shall not be less than 95%.
2 Principle
After formaldehyde gas is absorbed by water, then in the acetic acid-ammonium
acetate buffer solution of PH=6, it has chemical action with acetylacetone. Under the
condition of boiling water bath, it quickly generates stable yellow compound. Measure
it at wavelength of 413 nm. The response equation is as follows.
3 Reagents
Unless otherwise specified, when analyzing, it shall use the analytical pure reagents
which comply with national standard and the water prepared according to 3.1.
3.1 Organic-free distilled water.
Add a small mount of alkaline solution of potassium permanganate into water. Then
distill it (Water shall always be red throughout the whole distillation process, or
potassium permanganate shall be added at any time).
3.2 Absorbing liquid. The organic-free double distilled water (3.1).
3.3 Ammonium acetate (NH4CH3COO).
3.4 Glacial acetic acid (CH3COOH). ρ=1.055.
3.5 Acetylacetone (C5H8O2). ρ=0.975.
3.6 Hydrochloric acid (HCl) solution. ρ=1.19 (1+5).
3.7 Sodium hydroxide (NaOH) solution. 30g/100ml.
3.8 Iodine (I2).
3.9 Potassium iodide (KI).
3.10 Potassium iodate (KIO3) solution c(1/6KIO3)=0.1000 mol/L. Weigh 3.567g of
potassium iodate which has been dried at 110°C for 2h. Dissolve into water. Dilute to
constant volume in the 1000ml flask.
3.11 Starch solution. 1g/100ml. Weigh 1g of starch. Mix them into paste with water.
Pour it into 100ml of boiling water. It is transparent solution. It shall be prepared before
using.
3.12 Sodium thiosulfate solution. c(Na2S2O3)=0.1 mol/L. Weigh 25g of sodium
thiosulfate solution (Na2S2O3•5H2O) and 2g of sodium (Na2CO3) to dissolve into
1000ml of water that has been freshly boiled and cooled. Store in the brown reagent
bottle. Filter after placing for 1 week. And mark the concentration.
4 Instruments
4.1 Sampler. Air sampler. The flow range is 0.2~1.0L/min (with flow measurement
device).
4.2 Soap film flowmeter.
4.6 Standard Pitot tube. With correction factor.
4.7 Inclined micro-manometer.
4.8 Sampling lead pipe. Teflon tube. Inner diameter is 6~7mm, with glass fiber filter in
front of the lead pipe.
4.9 Aneroid barometer.
4.10 Mercury thermometers. 0~100°C.
4.11 pH acidity.
5 Samples
5.1 Sample collection
Sampling system is in-series consisted of sampling lead pipe (4.8), sampling
absorption tube (4.3), and air sampler (4.1).
5.2 Sample storage
Collected sample shall be stored up at 2~5°C. Complete the analysis in 2 days, so as
to prevent formaldehyde from oxidation.
5.3 Calibration of sample volume
6 Steps
6.1 Drawing of calibration curve
Take 7 piece of 25ml colorimetric tube with stopper. Prepare the standard color
columns according to following table.
6.2 Sample determination
Transfer the after-absorbing sample solution into 50ml or 100ml flask. Use water to
dilute to constant volume. Take less than 10ml of sample (the drawn amount is
determined by sample concentration). In 25ml colorimetric tube (4.4), use water to fix
constant volume to 10.0ml scale.
6.3 Blank test
Use the absorbing liquid of blank absorption tube which does not sample on the spot
to perform blank determination according to (6.1).
7 Results and expression
7.1 Calculation formula
Calculate the formaldehyde absorbance y in the test sample with formula (6).
7.2 Precision and accuracy
Analyzed by 6 laboratories, the 2 samples containing 2.96mg/L and 3.55mg/L of
formaldehyde are consistent.
8 Precautions
Formaldehyde will be oxidized under the sunshine. Therefore, when sampling, it shall
use brown absorption tube. In the transport and storage process of sample, it shall
adopt the measures to avoid light.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 15516-1995 be delivered?Answer: The full copy PDF of English version of GB/T 15516-1995 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 15516-1995_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15516-1995_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 15516-1995 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB/T 15516-1995?A step-by-step guide to download PDF of GB/T 15516-1995_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 15516-1995". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|