HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 12598-2023 PDF English

US$245.00 · In stock · Download in 9 seconds
GB/T 12598-2023: Plastics - Ion exchange resin - Determination for the rate of sphericity after osmotic-attrition and attrition
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 12598: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 12598-2023English245 Add to Cart 0-9 seconds. Auto-delivery Plastics - Ion exchange resin - Determination for the rate of sphericity after osmotic-attrition and attrition Valid
GB/T 12598-2001English319 Add to Cart 3 days Determination for sphericity of ion exchange resins after attrition of osmotic attrition Obsolete
GB/T 12598-1990English199 Add to Cart 2 days Ion exchange resins--Determination for strength--Osmotic-attrited method Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 12598-2023
      

Similar standards

GB/T 12008.7   GB/T 12008.7   GB/T 12027   GB/T 18964.1   

GB/T 12598-2023: Plastics - Ion exchange resin - Determination for the rate of sphericity after osmotic-attrition and attrition


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT12598-2023
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 83.080.20 CCS G 31 Replacing GB/T 12598-2001 Plastics -- Ion exchange resin -- Determination for the rate of sphericity after osmotic-attrition and attrition ISSUED ON: SEPTEMBER 07, 2023 IMPLEMENTED ON: APRIL 01, 2024 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 Introduction ... 5 1 Scope ... 6 2 Normative references ... 6 3 Terms and definitions ... 6 4 Reagents and materials ... 7 5 Instruments and equipment ... 7 6 Specimen preparation ... 9 7 Test steps ... 9 8 Result calculation and presentation ... 11 9 Precision ... 12 10 Test report ... 12 Annex A (informative) Precision ... 13 Bibliography ... 15

Foreword

This document was drafted in accordance with the rules given in GB/T 1.1-2020 "Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents". This document replaces GB/T 12598-2001 "Determination for sphericity of ion exchange resins after attrition of osmotic attrition". Compared with GB/T 12598-2001, in addition to structural adjustments and editorial changes, the main technical changes are as follows: a) Added "saturated sodium chloride solution" and "silver nitrate indicator" to reagents and materials (see 4.4 and 4.5 of this Edition); b) Changed "treatment device" to "diagram of infiltration treatment column" (see Figure 1 in 5.1 of this Edition; Figure 1 in 6.1 of Edition 2001); c) Changed the provisions of ball mill (see 5.2 of this Edition; 6.2 of Edition 2001); d) Changed the provisions of roller (see 5.2.2 of this Edition; 6.3 of Edition 2001); e) Changed the provisions of porcelain ball. Added "Silicon nitride material". Changed "mass is 10 g ± 0.1 g" to "mass is 13.4 g ± 0.2 g" (see 5.2.3 of this Edition; 6.4 of Edition 2001); f) Added "Sample type processing" (see 6.2 of this Edition); g) Deleted the sieving step in "operation steps for rate of sphericity after osmotic- attrition" (see 8.1.1 of Edition 2001); h) Changed "add 6 ceramic balls (when measuring cation exchange resin) or 10 ceramic balls (when measuring anion exchange resin)" to "add 5 ceramic balls (when measuring cation exchange resin) or 8 ceramic balls (when measuring anion exchange resin)" (see 7.1.7 of this Edition; 8.1.3.2 of Edition 2001); i) Changed "add 10 ceramic balls" to "add 8 ceramic balls" (see 7.2.1 of this Edition; 8.2.2 of Edition 2001); j) Changed calculation and presentation of results (see Chapter 8 of this Edition; Chapter 9 of Edition 2001); k) Changed "tolerance" to "precision" (see Chapter 9 of this Edition; Chapter 10 of Edition 2001). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing authority shall not be held responsible for identifying any or all such patent rights. Plastics -- Ion exchange resin -- Determination for the rate of sphericity after osmotic-attrition and attrition

1 Scope

This document describes the method for determining the rate of sphericity after osmotic-attrition and the rate of sphericity after attrition of ion exchange resin under certain conditions of external forces. This document is applicable to the determination of the rate of sphericity after osmotic- attrition and the rate of sphericity after attrition for unused wet spherical ion exchange resin. For the determination of the rate of sphericity after attrition for dry spherical ion exchange resin, refer to this document.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 5475, Methods for sampling ion exchange resins GB/T 6682, Water for analytical laboratory use -- Specification and test methods GB/T 31703-2015, Ceramic ball bearings -- Silicon nitride balls

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. 3.1 rate of sphericity after osmotic-attrition Use acid and alkali of a certain concentration to apply penetration force to the ion exchange resin, and then apply pressure and friction to the ion exchange resin through rolling. The ion exchange resin subjected to these three forces is dried until it can roll freely and separated to obtain the percentage of the mass of spherical particles to the total mass of the sample, which is called the rate of sphericity after osmotic-attrition. 3.2 rate of sphericity after attrition After applying pressure and friction to the ion exchange resin by rolling, the ion Keys: 1 - Orthoglass exchange column; 2 - Rubber or silicone gasket; 3 - Orthoglass filter plate; 4 - Stopcock. Figure 1 -- Schematic diagram of the osmotic treatment column 5.2 Ball mill 5.2.1 Rotating device: It can drive the drum to rotate horizontally. The speed can be set to 125 r/min±3 r/min. 5.2.2 Drum: Inner diameter is φ82.0 mm±0.2 mm. Inner drum height is 125 mm±1 mm. It is made of stainless steel. The drum cover is tightly closed and does not leak. 5.2.3 Ceramic ball: Made of silicon nitride. Nominal diameter is 20 mm. Mass is 13.4 g±0.2 g. Other technical requirements shall comply with the requirements for grade G20 in GB/T 31703-2015. 5.3 Filter cloth The pore diameter is less than 0.07 mm. 5.4 Sampling tray Enamel or stainless steel tray. The bottom is smooth without grooves. The length is 45 cm±5 cm. The width is 35 cm±5 cm. 5.5 Funnel The caliber is 40 mm~50 mm. The outer diameter of the head is 6 mm~8 mm. 5.6 Separatory funnel The capacity is 250 mL. 5.7 Balance The graduation value is 1 mg. 5.8 Graduated cylinder Nominal capacity is 100 mL. Graduation is 1 mL. Nominal capacity is 25 mL. Graduation is 0.5 mL.

6 Specimen preparation

6.1 Sampling Follow the method specified in GB/T 5475. 6.2 Sample type processing Except for the sodium-type strongly acidic cation exchange resin, the chloride-type strongly basic anion exchange resin, the weakly acidic cation exchange resin, and the weakly basic anion exchange resin, other types of strongly acidic cation exchange resins and strongly basic anion exchange resins shall be treated into the sodium-type and chloride-type respectively according to the following steps: a) Transfer 100 mL of sample to the infiltration treatment column. Add 1 L of saturated sodium chloride solution. Pass through the ion exchange resin layer at a flow rate of 15 mL/min~20 mL/min; b) Wash the ion exchange resin layer with water at the same flow rate until no white precipitate is observed when silver nitrate indicator is added to the collected 3 mL~5 mL of washing effluent; c) The transformed samples to be tested are collected for later use.

7 Test steps

7.1 Determination of rate of sphericity after osmotic-attrition 7.1.1 Use a 25 mL measuring cylinder to measure 16 mL±0.5 mL of the specimen. Tap the ion exchange resin until the volume is constant and read the value. Transfer to the infiltration treatment column with water. Drain the water. 7.1.2 Close the stopcock of the osmotic treatment column. Add 25 mL of water. Adjust the stopcock opening so that the water is completely discharged within 10 s~15 s. 7.1.3 Place a funnel (5.5) on the osmotic treatment column. Quickly pour in 25 mL of the treatment solution in step 1 in Table 1. The ion exchange resin shall be able to flip up and down when adding liquid and the solution shall be completely discharged within 10 s~15 s. Repeat the operation 5 times. Close the stopcock of the osmotic treatment column. Pour in 20 mL of the same treatment solution. 7.1.4 Remove the funnel (5.5). Replace it with a separatory funnel (5.6) and add 250 mL of the treatment solution in 7.1.3 to the separatory funnel. Open the stopcock of the osmotic treatment column. Allow the treatment solution to flow out in 10 min±30 s. 7.1.5 Close the stopcock of the grinding column. Remove the separatory funnel. Add 25 mL of water to the grinding column. Install a clean separatory funnel and add 250 mL of water to it. Open the stopcock of the grinding column and allow the water to flow out for 5 min±15 s. 7.1.6 Use the treatment solution in step 2 of Table 1 and water according to 7.1.3~7.1.5. 7.1.7 Use 50 mL of water to transfer all the ion exchange resin treated in 7.1.6 into the drum. Add 5 porcelain balls (when measuring cation exchange resin) or 8 porcelain balls (when measuring anion exchange resin). Tighten the drum cap. NOTE: Compared with GB/T 12598-2001, the adjustments made to the porcelain balls in this document have no significant impact on the test results. 7.1.8 Fix the roller to the ball mill. Start the ball mill. The rolling time of the cation exchange resin is 10 min±2 s. The rolling time of the anion exchange resin is 20 min±4 s. 7.1.9 Remove the drum and use water to move the drum cover and all the ion exchange resin in the drum onto the filter cloth. 7.1.10 Dry at 60°C or air dry until the ion exchange resin particles can roll freely. 7.1.11 Transfer all the dried ion exchange resin on the filter cloth to the upper left corner of the sampling tray. Lift the upper edge of the sampling tray and place it at an angle. Adjust the angle of inclination so that the spherical particles roll down with gentle vibration and the broken particles cannot roll down. Use a brush to gently move a small part of the ion exchange resin to separate the spherical particles from the broken particles. Brush the broken particles to the upper right corner until all the spherical particles and broken particles are separated. In the specimen after separation, the remaining broken particles in the spherical particles and the remaining spherical particles in the broken particles shall be less than 50 particles, accurate to 5 particles. 7.1.12 Observe the state of the residual particles after separation. Any abnormality shall be recorded. 7.1.13 Weigh the mass of the spherical particles (m1) and the mass of all particles (spherical particles and broken particles) (m2) on a balance, accurate to 1 mg. 7.2 Determination of rate of sphericity after attrition ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 12598-2023 be delivered?

Answer: The full copy PDF of English version of GB/T 12598-2023 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 12598-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 12598-2023_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 12598-2023 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 12598-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12598-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 12598-2023?

A step-by-step guide to download PDF of GB/T 12598-2023_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 12598-2023".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9