HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (23 Mar 2025)

GB/T 11944-2012 PDF English (GB/T 11944-2002: Older version)


Search result: GB/T 11944-2012 (GB/T 11944-2002 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 11944-2012English145 Add to Cart 0-9 seconds. Auto-delivery. Insulating glass unit Valid
GB/T 11944-2002English519 Add to Cart 4 days Sealed insulating glass unit Obsolete
GB/T 11944-1989English279 Add to Cart 3 days Sealed insulating glass Obsolete


PDF Preview: GB/T 11944-2012


GB/T 11944-2012: PDF in English (GBT 11944-2012)

GB/T 11944-2012 ICS 81.040 Q 33 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing GB/T 11944-2002 Insulating glass unit 中空玻璃 ISSUED ON. DECEMBER 31, 2012 IMPLEMENTED ON. SEPTEMBER 1, 2013 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China; Standardization Administration of the People’s Republic of China Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 5 4 Classification ... 6 5 Material ... 6 6 Requirements ... 6 7 Test methods ... 9 8 Inspection rules ... 19 9 Packaging, marks, transportation and storage... 21 Annex A ... 23 Annex B ... 24 Annex C ... 27 Annex D ... 29 Annex E ... 34 Foreword This Standard is drafted according to the rules specified in GB/T 1.1-2009. Compared with GB/T 11944-2002, in addition to editorial changes, the main technical changes of this Standard are as follows. — DELETE the requirements of insulating glass unit specification (See the Version 4 in 2002); — ADD requirements on dislocation (See 6.1.4); — Thickness of sealant layer is changed into width of sealant layer, and requirements are modified (See 6.1.5, the Version 5.2.4 in 2002); — MODIFY the appearance requirements of insulating glass unit (See 6.2, the Version 5.3 in 2002); — DELETE the sealing performance requirements (See the Version 5.4 in 2002); — DELETE the durability of climate cycle (See the Version 5.7 in 2002); — DELETE the requirements on durability of high temperature and humidity (See the Version 5.8 in 2002); — ADD the requirements on durability of water vapor seal (See 6.5); — ADD requirements on initial gas content of inflatable insulating glass unit (See 6.6); — ADD requirements on the gas seal durability of inflatable insulating glass unit (See 6.7); — ADD requirements on Value 17 (See 6.8); — MODIFY the test method of dew point (See 7.3, the Version 6.4 in 2002); — ADD description about failure cause and service life of insulating glass unit (See Annex A); — ADD methods for testing edge sealing bond performance (See Annex B); — ADD methods for testing water vapor permeability of edge sealing material (See Annex C); — ADD methods for testing moisture content in drying agent (See Annex D); — ADD description about optical phenomenon and visual quality of insulating glass unit (See Annex E); This Standard adopts the redrafting method and is prepared with reference to EN1279.2002 Insulating glass unit for Building. Of which the degree of consistency is not equivalent to this Standard. This Standard was proposed by China Building Material Council. This Standard is administered by the National Architectural Glass Standardization Technical Committee (SAC/TC 255). The organizations responsible for drafting this Standard are. Qinhuangdao Glass Industry Research and Design Institute, National Glass Quality Supervision and Inspection Center, and China Building Material Test & Certification Center. The organizations participating in drafting this Standard are. Shanghai Yaohua Pilkington Glass Co., Ltd., Dow Corning (China) Investment Co., Ltd., CSG Holding Co., Ltd., Hangzhou Zhijiang Silicone Chemicals Co., Ltd., Xinyi Glass Holdings Co., Ltd., Zhengzhou Zhongyuan Applied Technology Research and Development Co., Ltd., Zhengzhou Fulong New Materials Technology Co., Ltd., Wuxi Saili Molecular Sieve Co., Ltd., Chengdu Guibao Science and Technology Co., Ltd., Guangzhou Baiyun Chemical Industry Co., Ltd., CHAC Technology Co., Ltd., and Dongying Shengming Glass Co., Ltd. The main drafters of this Standard are. Ji Shuwei, Liu Zhifu, Li Yong, Wang Lixiang, Dong Fenglong, Li Xiaojie, Shi Xinyong, Wang Tiehua, Wang Wenkai, Liu Ming, Sun Dahai, Xu Wuyi, Li Buchun, and Li Xinda. The previous versions replaced by this Standard are as follows. — GB 7020-1986; — GB 11944-1989; — GB/T 11944-2002. Insulating glass unit 1 Scope This Standard specifies the terms, definitions, classification, requirements, test methods, inspection rules. Packaging, marks, transportation and storage of Insulating glass unit. This Standard applies to the insulating glass unit used for cold storage, decoration and transportation in the field of building and other fields, and can be taken as reference by the insulating glass unit used for other purposes. 2 Normative references The articles contained in the following documents have become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this Standard. GB/T 1216 External micrometer GB/T 8170 Rules of rounding off for numerical values & expression and judgment of limiting values GB/T 22476 Calculation and determination of steady-state U values (thermal transmittance) of multiple glazing 3 Terms and definitions The following terms and definitions are applicable to this document. 3.1 Insulating glass unit 2 or more sheets of glass are separated with effective support and are bond-sealed at edges, thus it becomes the glass product with dry gas space in between the glass layers. Note. quality of various materials for producing insulating glass unit is closely related to the service life of insulating glass unit; therefore, the material required in standard specification shall be used in insulating glass unit production, and generally its service life shall not less than 15 years, see Annex A. 4 Classification 4.1 Classified according to the shape Flat insulating glass; Curved surface insulating glass. 4.2 Classified according to the gas inside the hollow cavity Ordinary insulating glass unit. the insulating glass unit with air in the hollow cavity; Inflatable insulating glass unit. the insulating glass unit with argon, krypton and other gases in the hollow cavity. 5 Material 5.1 Glass The sheet glass, coated glass, laminated glass, toughened glass, fire-resistant glass, semi-toughened glass, figured glass and other glasses can be adopted. The glass used shall be in compliance with the corresponding standard requirements. 5.2 Edge sealing materials The edge sealing materials for insulating glass unit shall comply with the corresponding standard requirement, and shall be able to realize the water vapor and gas seal performance of insulating glass unit and keep the insulating glass unit structure stable. Sealant bond performance and water vapor permeability of edge sealing materials are shown in Annex B and C. 5.3 Spacing materials Spacing materials can be aluminum spacing strip, stainless steel spacing strip, composite spacing strip, composite gaskets, etc., and shall conform to the requirements of relevant standards and technical documents. 5.4 Desiccant Desiccant shall be in compliance with the requirements of relevant standards. 6 Requirements The performance and test methods of insulating glass unit shall comply with the provisions of the corresponding terms in Table 1. than 15mm. Damage during the test is allowed to occur to 1 sample, and replace the spare sample to retest. First carry out 28 high-low temperature cycle tests according to test method for stage 1 specified under 7.5.2, then carry out constant temperature and humidity test for 4 weeks according to the test method for stage 2. After test, place the sample under the temperature of 23ºC±2ºC, relative humidity of 30%-75% for at least 24h, then measure gas content as specified under 7.6. Insulating glass unit with two cavities shall be respectively measured. 7.8 U value U value of insulating glass unit shall be calculated or measured according to the method specified in GB/T 22476. 8 Inspection rules 8.1 Inspection classification 8.1.1 Type inspection Type inspections include all inspection items in the technical requirements. Type inspection shall be carried out if one of the following circumstances occurs. a) There are major changes in structure, material or process and such changes would affect the product performance in process of production; b) In normal production, it shall periodically carry out one inspection on a regular basis or after the accumulation of certain amount; c) Resumption of... ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.