GB 1903.47-2020 PDF English
Search result: GB 1903.47-2020_English: PDF (GB1903.47-2020)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB 1903.47-2020 | English | 115 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
National food safety standard - Food nutritional fortification substance - Ferrous lactate
| Valid |
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB 1903.47-2020 Related standards: GB 1903.47-2020
PDF Preview: GB 1903.47-2020
GB 1903.47-2020: PDF in English GB 1903.47-2020
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National Food Safety Standard - Food Nutritional
Fortification Substance - Ferrous Lactate
ISSUED ON: SEPTEMBER 11, 2020
IMPLEMENTED ON: MARCH 11, 2021
Issued by: National Health Commission of the People’s Republic of China;
State Administration for Market Regulation.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Chemical Name, Molecular Formula, Structural Formula and Relative
Molecular Mass ... 4
3 Technical Requirements ... 5
Appendix A Inspection Method ... 6
National Food Safety Standard - Food Nutritional
Fortification Substance - Ferrous Lactate
1 Scope
This Standard is applicable to food nutritional fortification substance - ferrous lactate,
which is obtained through the reaction between sodium lactate and ferrous sulfate, or
sodium lactate and ferrous chloride, or calcium lactate (ammonium lactate) and ferrous
sulfate (ferrous chloride), or lactic acid and iron powder.
2 Chemical Name, Molecular Formula, Structural
Formula and Relative Molecular Mass
2.1 Chemical Name
2-ferrous hydroxypropionate
2.2 Molecular Formula
C6H10FeO6 nH2O (n = 2 or 3)
2.3 Structural Formula
2.4 Relative Molecular Mass
270.02 (dihydrate) (in accordance with the international relative atomic mass of Year
2018)
288.03 (trihydrate) (in accordance with the international relative atomic mass of Year
2018)
Appendix A
Inspection Method
A.1 General Provisions
When no other requirements are indicated, the reagents and water used in this
Standard refer to analytically pure reagents and Grade-3 water specified in GB/T 6682.
When no other requirements are indicated, the standard titration solutions, and
standard solutions, preparations and products for impurity determination shall be
prepared in accordance with the stipulations of GB/T 601, GB/T 602 and GB/T 603.
When the solvent used for solution preparation is not specified, it refers to aqueous
solution in the tests.
A.2 Identification Test
A.2.1 Reagents and materials
A.2.1.1 Ethanol.
A.2.1.2 Potassium permanganate solution: 3.2 g/L.
A.2.1.3 Sulfuric acid solution: 1 + 20.
A.2.1.4 Potassium ferricyanide solution: 100 g/L.
A.2.1.5 Hydrochloric acid solution: 1 + 3.
A.2.1.6 Morpholine solution: 1 + 4.
A.2.1.7 Sodium nitroferricyanide dihydrate solution: 50 g/L.
A.2.1.8 Sodium hydroxide solution: 43 g/L.
A.2.2 Identification method
A.2.2.1 Solubility
It is slightly soluble in water, and almost insoluble in ethanol.
A.2.2.2 Identification of lactate
Weigh-take about 1.0 g of the sample and dissolve it in 50 mL of water, so as to prepare
the sample solution. Take 5 mL of the sample solution; add 2 mL of sulfuric acid solution
and mix it well. Then, add 2 mL of potassium permanganate solution; heat it up;
acetaldehyde gas shall be generated. The identification of acetaldehyde gas adopts a
V1---the volume of the cerium sulfate standard titration solution consumed by the
titration of the sample solution, expressed in (mL);
V0---the volume of the cerium sulfate standard titration solution consumed by the
titration of the blank solution, expressed in (mL);
c1---the concentration of the cerium sulfate standard titration solution, expressed in
(mol/L);
M1---the molar mass of ferrous lactate, expressed in (g/mol) [M1 (C6H10FeO6) = 233.96];
m1---the mass of the sample, expressed in (g);
w2---the mass fraction of actually measured sample water content, expressed in (%);
1,000---conversion factor.
Take the arithmetic mean value of two parallel determination results as the
determination result. The absolute difference between two parallel determination
results shall not exceed 2% of the arithmetic mean value.
A.4 Determination of Water Content
A.4.1 Reagents
A.4.1.1 Anhydrous methanol (CH4O): guaranteed reagent.
A.4.1.2 Formamide: guaranteed reagent.
A.4.1.3 Extraction solvent: mix anhydrous methanol (A.4.1.1) and formamide (A.4.1.2)
by 1 + 1 (volume ratio); shake it well.
A.4.1.4 Karl Fischer reagent.
A.4.2 Instruments and equipment
A.4.2.1 Karl Fischer moisture analyzer.
A.4.2.2 Electronic balance: with a division value of 0.1 mg.
A.4.3 Analytical procedures
Weigh-take 0.1 g of the sample (accurate to 0.0001 g); add it to an appropriate amount
of extraction solvent (A.4.1.3). While stirring it, use Karl Fischer reagent for titration,
until it reaches the end point. In accordance with GB/T 606, determine the water
content in it.
A.5 Determination of Trivalent Iron (calculated as Fe3+)
m2---the mass of the sample, expressed in (g);
1,000---conversion factor.
Take the arithmetic mean value of two parallel determination results as the
determination result. The absolute difference between two parallel determination
results shall not exceed 10% of the arithmetic mean value.
A.6 Determination of Chloride (calculated as Cl)
A.6.1 Reagents and materials
A.6.1.1 Nitric acid solution: 1 + 9.
A.6.1.2 Silver nitrate solution: 17 g/L.
A.6.1.3 Chloride (Cl) standard solution: after preparing it in accordance with GB/T 602,
dilute it to the equivalent of 0.01 mg of chloride ion per 1 mL.
A.6.2 Analytical procedures
Weigh-take 0.1 g of the sample (accurate to 0.01 g); place it in a 50 mL Nessler
colorimetric tube. Add an appropriate amount of water and 10 mL of nitric acid solution
to dissolve it; add 1 mL of silver nitrate solution; use water to dilute it to 50 mL; shake
it well, then, place it in a dark place for 5 min. Under a black background, axially
observe it; compare the manifested turbidity with that of the standard turbidity solution.
Standard turbidity solution: measure-take 10 mL of chloride standard solution and
place it in a 50 mL colorimetric tube. Process it at the same time and in the same mode
as the sample solution.
A.6.3 Result determination
The manifested turbidity of the sample solution shall not be deeper than that of the
standard turbidity solution. In other words, the chloride in the sample is not greater
than 0.1%.
A.7 Determination of Sulfate (calculated as SO4)
A.7.1 Reagents and materials
A.7.1.1 Hydrochloric acid solution: 1 + 4.
A.7.1.2 Barium chloride solution: 250 g/L.
A.7.1.3 Sulfate (SO4) standard solution: after preparing it in accordance with GB/T 602,
dilute it to the equivalent of 0.01 mg of sulfate ion per 1 mL.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|