HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (13 Jul 2025)

GB 15213-2016 (GB 15213-1994) PDF English

US$165.00 · In stock · Download in 9 seconds
GB 15213-1994: Medical electron accelerators -- Functional performance characteristics and test methods
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete

GB 15213: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 15213-2016English1859 Add to Cart 13 days Medical electron accelerators -- Functional performance characteristics and test methods Valid
GB 15213-1994English165 Add to Cart 0-9 seconds. Auto-delivery Medical electron accelerators - Functional performance characteristics and test methods Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 15213-1994                   
      


      


Similar standards

GB/T 40618   

GB 15213-1994: Medical electron accelerators - Functional performance characteristics and test methods


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB15213-1994
GB UDC 615.47; 621.3.038.624 F 91 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA GB 15213-94 Medical Electron Accelerators – Functional Performance Characteristics and Test Methods Issued on: SEPTEMBER 24, 1994 Implemented on: MARCH 01, 1995 Issued by. State Bureau of Technical Supervision the People's Republic of China

Table of Contents

1  Subject content and scope of application ... 3 2  Terms and references ... 4 2.1  Terms ... 4 2.2  References ... 4 3  Performance indexes ... 4 3.1  Dose monitoring system ... 4 3.2  Depth absorbed dose characteristics ... 7 3.3  Flatness of radiation field ... 9 4  Test methods ... 17 4.1  Standardized test conditions ... 17 4.1.1  Angular position ... 17 4.1.2  Materials and position of phantom ... 18 4.1.3  Position of testing point ... 18 4.1.4  Radiation detector ... 18 4.1.5   Standard testing depth ... 19 4.1.6  Radiation field ... 19 4.1.7  Adjustment during the test ... 19 4.2  Dose monitoring system ... 19 4.3  Depth absorbed dose characteristics ... 25 4.4  Uniformity of radiation field ... 28 4.5  Indication of radiation fields ... 33 4.6  Indication of radiation beam axis ... 37 4.7  Isocentre ... 39 4.8  Indication of distance along the radiation beam axis ... 40 4.9  Zero position of rotational scales ... 41 4.10  Congruence of opposed radiation fields ... 43 4.11  Movements of the patient table ... 43 Additional Information ... 54 National Standard of the People’s Republic of China Medical Electron Accelerators – Functional Performance Characteristics and Test Methods GB 15213-94 This standard equivalently adopts the international standard IEC 976 (1989) Medical Electron Accelerators - Functional Performance Characteristics and IEC977 (1989) Medical electron accelerators in the range 1 MeV to 50 MeV -Guidelines for functional performance characteristics. 1 Subject content and scope of application This standard specifies the performance index and test methods of medical electron accelerators. This standard applies to medical electron accelerators used for therapy purpose in human medical practice. This standard applies to medical electron accelerators which can generate X-radiation and electron radiation; its nominal energies is 1~50MeV, maximum dose rates is 0.001Gy ~ 1Gy/s at 1m from the radiation source, normal treatment distance (NTD) is 50cm ~ 200cm. This standard applies to the medical electron accelerators equipped with isocentric gantry, and the performance characteristics and test methods for non-isocentric equipment may be corrected properly. Unless otherwise specified in the accompanying documents, this standard applies to the equipment installed and used in the environment under the following conditions. a. Temperature 15~35°C b. Relative humidity 30%~75% c. Atmospheric pressure 7×104~11×104Pa (700~1100mbar) The transportation and storage environmental conditions must be stated in the Additional Information This standard was proposed by State Pharmaceutical Administration and shall be under the jurisdiction of Beijing Medical Equipment Institute. This standard was drafted by Beijing Medical Equipment Institute. Chief drafting staffs of this standard are Zhang Zhaoyuan, Wu Wei, and Wang Xiaoyun. Since the implementation date of this Standard, ZB F91 002-88 "Medical Electron Accelerators-Functional Performance Characteristics and Test Methods" issued by State Pharmaceutical Administration shall be abolished. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.