HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (3 Nov 2024)

GB 13172-2009 PDF in English


GB 13172-2009 (GB13172-2009) PDF English
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB 13172-2009English115 Add to Cart 0-9 seconds. Auto-delivery. [GB/T 13172-2009] Molybdenum 99 -- Technetium 99m chromatographic generator (fission) [Renamed to GB/T 13172-2009] Valid
GB 13172-1991English239 Add to Cart 2 days 99Mo_99Tc chromatographic generator (Fission) Obsolete
GB 13172.1-1991EnglishRFQ ASK 3 days (Soft white sugar) Obsolete
Standards related to (historical): GB 13172-2009
PDF Preview

GB 13172-2009: PDF in English

GB 13172-2009 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.120.01 F 54 Replacing GB 13172-1991 Molybdenum 99-Technetium 99m chromatographic generator (fission) 裂变钼 99-锝 99m色层发生器 ISSUED ON. MARCH 13, 2009 IMPLEMENTED ON. MARCH 01, 2010 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Table of contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Product specifications ... 6  5 Technical requirements ... 7  6 Test methods ... 8  7 Inspection rules ... 10  8 Product marking, label and instruction manual ... 11  9 Packaging, transportation and storage ... 11  Foreword All the technical contents of this standard are mandatory. This standard replaces GB 13172-1991 “Molybdenum 99-Technetium 99m chromatographic generator (fission)”. As compared with GB 13172-1991, the main changes of this standard are as follows. a) MODIFY the standard name; b) ADD 5 normative references; c) CHANGE the test and determination in the original standard into inspection; d) DELETE clause 3.3 of the original standard; ADD such items as the elution, eluate, calibration time, and aluminum concentration, etc.; e) CHANGE the sodium chloride injection of the original standard into elution; f) DELETE the Chapter 4 from the original standard; g) ADD the new product specifications; h) DELETE the clause 6.1.1 and 6.1.4 from the original standard; i) ADD the technical requirements for radioactive contamination of the generator surface; j) ADJUST the clause 6.2.9 of the original standard into the technical requirements of the generator; k) DELETE the clause 7.2 from the original standard; l) ADD the chapter of inspection rules; m) SPLIT the original chapter 8 into two chapters. Marking, sign and instruction manual, AND packaging, transportation, and storage. This standard was proposed by China National Nuclear Corporation. This standard shall be under the jurisdiction of the National Nuclear Energy Standardization Technical Committee. The drafting organization of this standard. China Atomic Energy Research Institute. The drafters of this standard. Niu Xuxiang, Chen Daming, Liu Guangyu. Molybdenum 99-Technetium 99m chromatographic generator (fission) 1 Scope This standard specifies the technical requirements, inspection methods, inspection rules, marking, inspection certificate and instruction manual, packaging, transportation and storage of molybdenum 99-Technetium 99m chromatographic generator (fission). This standard applies to the medical molybdenum 99-Technetium 99m chromatographic generator which uses the Al2O3 as the adsorbent; AND it is not applicable to the technetium 99m generator of other types. 2 Normative references The provisions in following documents become the provisions of this Standard through reference in this Standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard; however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB 11806 Regulations for the safe transport of radioactive material GB/T 15239 Sampling procedures and tables for isolated lot inspection by attributes EJ/T 843-1994 Radioactive nuclide activity measurement - Well-type ionization chamber method EJ/T 845-1994 Radioactive drug solution – pH determination method State Food and Drug Administration Note [2006] No.264 “Detailed rules for the radioactive drug instruction specification” People's Republic of China Pharmacopoeia II (2005 version) 3 Terms and definitions The following terms and definitions apply to this standard. 3.1 Molybdenum 99-technetium 99m chromatographic generator (fission) 89Sr. 6 × 10-5% 90Sr. 6 × 10-6% α impurity nuclide. 1 × 10-7% Other total β, γ nuclide. 1 × 10-2% 5.2.5 Radiochemical purity Na99mTcO4 content shall not be less than 98%. 5.2.6 Activity The activity of the 99mTc eluted from the generator shall be 90.0% ~ 110.0% of the indicated amount if calculated in accordance with the calibration time. 5.2.7 Bacterial endotoxin It shall comply with the provisions of the People's Republic of China Pharmacopoeia II (2005 version). 5.2.8 Sterile It shall comply with the provisions of the People's Republic of China Pharmacopoeia II (2005 version). 6 Test methods 6.1 Generator test 6.1.1 Eluting efficiency In accordance with the calibration time and product specifications, CALCULATE the activity A1 of the 99mTc in the generator at the time of eluting; USE 10 mL of elution to elute the generator; DETERMINE the activity A2 of the 99mTc in the generator; USE the formula (1) to calculate the eluting efficiency η. Where. η - Eluting efficiency, expressed as a percentage; A1 - The activity of the 99mTc in the generator at the time of eluting, in becquerel (Bq); A2 - The activity of the 99mTc in the eluate, in becquerel (Bq). 6.1.2 Surface radioactive contamination 8 Product marking, label and instruction manual 8.1 Marking Generator outer packaging shall have the following markings. a) Radioactive marking; b) Radioactive transportation level marking; c) Markings of rainproof, handle with care, and face upwards. 8.2 Label The label is divided into inner packaging label and outer packaging label. The inner packaging label is attached to the generator surface; AND the outer packaging label is attached to the outer packaging. The label shall have the following information. a) Product name; b) Radioactive marking; c) Approval document number; d) Specifications; e) Product lot number; f) Radioactive activity; g) Calibration time (or reference time); h) Validity period; i) Manufacturer. 8.3 Instruction manual The generator shall be supplied with the instruction manual at the time of exit-factory. The contents of the instruction manual shall be in accordance with the provisions of the State Food and Drug Administration [2006] No.264. 9 Packaging, transportation and storage 9.1 Packaging Product packaging is lead can, foam liner, and iron drum in the order in the order from the inside out, AND the surface radioactive pollution levels and radiation levels shall comply with the provisions of GB 11806. ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.