HOME Cart Quotation About-Us
www.ChineseStandard.net
Database: 221479 (21 Mar 2026)
Path: Home > GB/T > Page202 > GB/T 37945-2019

GB/T 37945-2019 PDF English

Price & Delivery

US$119.00 · In stock · Download in 9 seconds
GB/T 37945-2019: Materials for organic light emitting diode display (OLED) - Test method of glass transfer temperature - Differential scanning calorimetry (DSC)
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
GB/T 37945-2019English119 Add to Cart 3 days [Need to translate] Materials for organic light emitting diode display (OLED) - Test method of glass transfer temperature - Differential scanning calorimetry (DSC)

Basic data

Standard ID GB/T 37945-2019 (GB/T37945-2019)
Description (Translated English) Materials for organic light emitting diode display (OLED) - Test method of glass transfer temperature - Differential scanning calorimetry (DSC)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L90
Classification of International Standard 31.030
Word Count Estimation 6,699
Date of Issue 2019-08-30
Date of Implementation 2019-12-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 37945-2019: Materials for organic light emitting diode display (OLED) - Test method of glass transfer temperature - Differential scanning calorimetry (DSC)





---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT37945-2019
(Materials for organic light-emitting diode displays Glass transition temperature test method Differential thermal method) ICS 31.030 L90 National Standards of People's Republic of China Organic light-emitting diode display material Glass transition temperature test method differential thermal method Materialsfororganiclightemittingdiodedisplay(OLED)-Testmethodof glasstransfertemperature-Differentialscanningcalorimetry(DSC) Published on.2019-08-30 2019-12-01 implementation State market supervision and administration China National Standardization Administration issued Content Foreword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Principle 1 5 Instruments and materials 1 6 Environmental conditions 1 7 Operation Step 1 8 results indicate 2 9 Test report 3

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard is proposed and managed by the National Semiconductor Equipment and Materials Standardization Technical Committee (SAC/TC203). This standard was drafted. China Electronics Technology Standardization Institute, Beijing Dingcai Technology Co., Ltd., Shanghai Tianma Microelectronics Co., Ltd. Division, Gu'an Dingcai Technology Co., Ltd., Tianma Microelectronics Co., Ltd., Shanghai University. The main drafters of this standard. Wang Xiang, Liu Wei, Gao Wenzheng, Huang Yu, and Wang Xing. Organic light-emitting diode display material Glass transition temperature test method differential thermal method

1 Scope

This standard specifies the use of differential scanning calorimetry (DSC) for the determination of organic materials for organic light-emitting diode (OLED) displays. Test method for glass transition temperature (Tg). This standard applies to small molecules and polymer materials for OLED.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 22567-2008 Test method for determining glass transition temperature of electrical insulating materials JJG936-2012 Differential Scanning Calorimeter Verification Procedure JJG1036-2008 Electronic Balance Verification Procedure

3 Terms and definitions

The terms and definitions defined in GB/T 22567-2008 apply to this document.

4 Principle

Measure the heat flow rate (thermal power) difference between the input sample and the reference sample with temperature and/or time under the specified atmosphere and program temperature control The relationship between changes. The curve with the temperature or time as the X-axis and the heat flow rate difference or the thermal power difference as the Y-axis is the DSC curve.

5 instruments and materials

5.1 Differential scanning calorimeter, qualified according to JJG936-2012. 5.2 Analytical balance (sensing 0.1mg), qualified according to JJG1036-2008.

6 Environmental conditions

6.1 Ambient temperature is 15 ° C ~ 30 ° C. 6.2 Relative humidity. ≤ 85%.

7 Operating steps

7.1 boot 7.1.1 Turn on the instrument until the instrument reaches a steady state. GB/T 37945-2019 (Materials for organic light-emitting diode displays Glass transition temperature test method Differential thermal method) ICS 31.030 L90 National Standards of People's Republic of China Organic light-emitting diode display material Glass transition temperature test method differential thermal method Materialsfororganiclightemittingdiodedisplay(OLED)-Testmethodof glasstransfertemperature-Differentialscanningcalorimetry(DSC) Published on.2019-08-30 2019-12-01 implementation State market supervision and administration China National Standardization Administration issued Content Foreword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Principle 1 5 Instruments and materials 1 6 Environmental conditions 1 7 Operation Step 1 8 results indicate 2 9 Test report 3

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard is proposed and managed by the National Semiconductor Equipment and Materials Standardization Technical Committee (SAC/TC203). This standard was drafted. China Electronics Technology Standardization Institute, Beijing Dingcai Technology Co., Ltd., Shanghai Tianma Microelectronics Co., Ltd. Division, Gu'an Dingcai Technology Co., Ltd., Tianma Microelectronics Co., Ltd., Shanghai University. The main drafters of this standard. Wang Xiang, Liu Wei, Gao Wenzheng, Huang Yu, and Wang Xing. Organic light-emitting diode display material Glass transition temperature test method differential thermal method

1 Scope

This standard specifies the use of differential scanning calorimetry (DSC) for the determination of organic materials for organic light-emitting diode (OLED) displays. Test method for glass transition temperature (Tg). This standard applies to small molecules and polymer materials for OLED.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 22567-2008 Test method for determining glass transition temperature of electrical insulating materials JJG936-2012 Differential Scanning Calorimeter Verification Procedure JJG1036-2008 Electronic Balance Verification Procedure

3 Terms and definitions

The terms and definitions defined in GB/T 22567-2008 apply to this document.

4 Principle

Measure the heat flow rate (thermal power) difference between the input sample and the reference sample with temperature and/or time under the specified atmosphere and program temperature control The relationship between changes. The curve with the temperature or time as the X-axis and the heat flow rate difference or the thermal power difference as the Y-axis is the DSC curve.

5 instruments and materials

5.1 Differential scanning calorimeter, qualified according to JJG936-2012. 5.2 Analytical balance (sensing 0.1mg), qualified according to JJG1036-2008.

6 Environmental conditions

6.1 Ambient temperature is 15 ° C ~ 30 ° C. 6.2 Relative humidity. ≤ 85%.

7 Operating steps

7.1 boot 7.1.1 Turn on the instrument until the instrument reaches a steady state.
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 37945-2019_English be delivered?


Answer: Upon your order, we will start to translate GB/T 37945-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 37945-2019_English with my colleagues?


Answer: Yes. The purchased PDF of GB/T 37945-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Terms of Service | Contact | Privacy | Refund | Shipping