GB/T 41336-2022: Classification and test method for fire resistant performance of curtain wall
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 41336-2022359 Add to Cart 4 days Classification and test method for fire resistant performance of curtain wall Valid

Similar standards

GB/T 43496   GB/T 38264   GB/T 38388   GB/T 29498   GB/T 41334   

Basic data

Standard ID: GB/T 41336-2022 (GB/T41336-2022)
Description (Translated English): Classification and test method for fire resistant performance of curtain wall
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: P32
Word Count Estimation: 18,188
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 41336-2022: Classification and test method for fire resistant performance of curtain wall

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Classification and test method for fire resistant performance of curtain wall ICS 91.060.10 CCSP32 National Standards of People's Republic of China Classification and test method of fire performance of building curtain wall Published on 2022-03-09 2022-10-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Fire performance classification 2 5 Test equipment and instruments 3 6 Test conditions 4 7 Specimen Requirements 6 8 Specimen installation and testing area 6 9 Measuring instrument arrangement 9 10 Test procedure 11 11 Test results and judgment 12 12 Test report 14

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This document is under the jurisdiction of the National Standardization Technical Committee for Building Curtain Walls and Doors and Windows (SAC/TC448). This document is drafted by. China Academy of Building Research Co., Ltd., Sichuan Fire Research Institute of Emergency Management Department, Tianjin Fire Department of Emergency Management Department Defense Research Institute, China Architectural Design and Research Institute Co., Ltd., Beijing Jangho Curtain Wall System Engineering Co., Ltd., Hebei Orun Shunda Window Industry Co., Ltd. Company, Hilti (China) Trading Co., Ltd., Foshan Nanhai Chongtai Fireproof Material Co., Ltd., Dongguan Yinjian Glass Engineering Co., Ltd., Beijing Building Materials Inspection and Research Institute Co., Ltd., Suzhou King Kong Fireproof Steel Profile System Co., Ltd., Harbin Huaxing Energy-saving Doors and Windows Co., Ltd. The company, Guangdong Jianlang Hardware Products Co., Ltd., ASSA ABLOY Guoqiang (Shandong) Hardware Technology Co., Ltd., and Jiangsu Iron Anchor Glass Co., Ltd. Co., Ltd., Fei Musheng (Shanxi) Material Technology Co., Ltd., Guangzhou Jitai Chemical Co., Ltd., Sijilia Aubi Window and Door Hardware (Sanhe) Co., Ltd., Bao Shilong (Beijing) Material Technology Co., Ltd., Guangdong Century Construction Group Co., Ltd., Zhongshan Zhongjia New Materials Co., Ltd. Company, Guangdong Chuangao Curtain Wall Door and Window Engineering Co., Ltd., Jinzhu Taiyang Decoration Co., Ltd., Hanergy Mobile Energy Holding Group Co., Ltd., Shanghai Construction Co., Ltd. Industrial Real Estate Co., Ltd., China Construction Curtain Wall Co., Ltd., Beijing Zhongrui Yuehua Engineering Management Consulting Co., Ltd., Heshan Boan Fireproof Glass Technology Co., Ltd., Shenzhen Tyco Testing Co., Ltd., Guangdong Weiwu Fire Protection Technology Co., Ltd., Zhuhai Xingye Green Building Technology Co., Ltd., Shandong Tianyuan Decoration Engineering Co., Ltd., Beijing Urban Construction Far East Construction Investment Group Co., Ltd., Guangdong Hengbao Defense Technology Co., Ltd., Qingdao Wanhe Building Decoration Group Co., Ltd., Parkson United Group Co., Ltd., Shenzhen Bauing Construction Group Co., Ltd., Bodi Construction Group Group Co., Ltd., SCHOTT (Shanghai) Precision Materials and Equipment International Trade Co., Ltd., Shanghai Jianke Inspection Co., Ltd., Guangdong Provincial Construction Engineering Co., Ltd. Quality and Safety Inspection Station Co., Ltd., Zhejiang Deyilong Technology Co., Ltd., Mingwei Technology Group Co., Ltd., Hunan Jinwei New Material Technology Co., Ltd., Greentown Decoration Engineering Group Co., Ltd., Luyu Huangjin Building Materials (Heyuan) Co., Ltd. The main drafters of this document. Zhang Xichen, Zhang Jingyan, Wang Hongtao, Fan Jiye, Peng Lei, Yin Chaolu, Zhao Chenggang, Sun Zhou, Han Weichi, Jiao Changlong, Li Xiang, Yin Shuxiang, Xiao Juncheng, Ma Guoru, Wu Congzhen, Zhang Zhoulai, Du Wanming, Sun Jichao, Wang Anchun, Ma Senyuan, Lin Kunhua, Li Pengyan, Hu Yineng, Xu Youchu, Li Jiangdong, Yang Cuijuan, Chen Fuwen, Wu Zhenyu, Qian Jin, Lu Hao, Zheng Xianguo, Hu Haiming, Wen Zhiqiang, Yin Liangjie, Li Weidong, Luo Duo, Song Xiaoyong, Qiu Zhengqing, Lu Shuqing, Li Menghe, Sheng Ribin, Liu Yuqi, Wang Haitong, Luo Yudong, Feng Jinghui, Ma Yehong, Zhang Minggang, Zhao Jiexue, Xie Binquan, Zhu Kuai, Zhou Guofu, Shan Bo, Su Xiaoshun. Classification and test method of fire performance of building curtain wall Warning. All staff performing this test should be aware that this test may cause personal injury. During the test, it is possible Toxic or harmful fumes and fumes are generated. During the installation process of the test piece, the test process and the cleaning process of the test piece after the test, it is possible to Mechanical injury and operational hazards occur. All potential hazards and health hazards should be analyzed before the test, and safety notices should be made. necessary for relevant personnel training. Laboratory staff should operate in strict accordance with safe operating procedures and take reliable protective measures.

1 Scope

This document specifies the fire performance classification of building curtain walls, test equipment and instruments, test conditions, test piece requirements, test piece installation and test area domain, measuring instrument arrangement, test procedure, test results and judgment and test report. This document is applicable to the fire protection of building curtain wall fire protection structure (including fire curtain wall, fire skirt wall, interlayer fire blocking and partition wall fire blocking) Performance classification and testing.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB/T 5907.1 Fire Fighting Vocabulary Part 1.General Terms GB/T 9978.1 Fire resistance test method for building components - Part 1.General requirements GB/T 12513 Fire resistance test method for glass-inlaid components GB/T 26784 Optional and additional test procedures for fire resistance test of building components GB/T 34327 Terms of Building Curtain Wall

3 Terms and Definitions

The terms and definitions defined in GB/T 5907.1, GB/T 34327 and the following apply to this document. 3.1 It is located in the inter-story floor or fire partition wall, and has certain fire resistance, which can block the gap of flame, smoke spread or heat transfer. and peripheral protection measures. 3.2 Under standard test conditions, the ability of building curtain wall fire protection structure to meet the requirements of fire integrity, fire insulation or radiant heat reduction. 3.3 Fire curtain wall fire-resistantcurtainwal The curtain wall structure is located at the opening of the exterior wall of the building and is used to prevent the spread of indoor and outdoor fires. 3.4 It is located between the outer wall of the building and the opening on the lower floor, and is used to prevent the spread of indoor and outdoor fires.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 41336-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 41336-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 41336-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 41336-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.