Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 39528-2020 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 39528-2020: Test method for determining the seismic drift causing the panels fallout from curtain wall system
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 39528-2020169 Add to Cart 3 days Test method for determining the seismic drift causing the panels fallout from curtain wall system Valid

Similar standards

GB/T 43496   GB/T 38264   GB/T 38388   GB/T 39525   GB/T 39524   

Basic data

Standard ID: GB/T 39528-2020 (GB/T39528-2020)
Description (Translated English): Test method for determining the seismic drift causing the panels fallout from curtain wall system
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: P32
Classification of International Standard: 91.060.10
Word Count Estimation: 9,973
Date of Issue: 2020-12-14
Date of Implementation: 2021-11-01
Quoted Standard: GB/T 18250; GB/T 34327
Regulation (derived from): National Standard Announcement No. 28 of 2020
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration
Summary: This standard specifies the testing principles, testing devices, test pieces, pre-test preparations, testing, testing results and testing reports for the earthquake-resistant shedding of building curtain wall panels. This standard is applicable to laboratory testing for earthquake resistance of building curtain wall panels.

GB/T 39528-2020: Test method for determining the seismic drift causing the panels fallout from curtain wall system


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Anti-seismic shedding detection method for building curtain wall panels) ICS 91:060:10 P32 National Standards of People's Republic of China Anti-seismic shedding detection method for building curtain wall panels 2020-12-14 release 2021-11-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Foreword Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Detection principle 1 5 Detection device 1 6 Specimen 2 7 Preparation before testing 3 8 Test 4 9 Test results 5 10 Test report 5 Appendix A (informative appendix) The scope of application of glass curtain wall test results 6

Foreword

This standard was drafted in accordance with the rules given in GB/T 1:1-2009: This standard was proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China: This standard is under the jurisdiction of the National Standardization Technical Committee for Building Curtain Walls, Doors and Windows (SAC/TC448): Drafting organizations of this standard: China Academy of Building Research Co:, Ltd:, Guangzhou Jitai Chemical Co:, Ltd:, Nantong Bluestar Decoration Engineering Co:, Ltd:, Guangdong Century Construction Group Co:, Ltd:, Guangdong Jianlang Hardware Products Co:, Ltd:, Shandong Biaozheng Inspection and Testing Co:, Ltd: Division, China Building Standard Design and Research Institute Co:, Ltd:, Guangdong Academy of Building Research Group Co:, Ltd:, China State Construction Eighth Project Bureau Co:, Ltd:, China State Construction Xinjiang Construction (Group) Co:, Ltd: The main drafters of this standard: Shi Qing, Qiu Ming, Yan Qiang, Lin Kunhua, Chen Jinglin, Wu Chenpeng, Du Wanming, Zhang Yijun, Sun Meifeng, Wang Junyang, Gu Taichang, He Xuan, Zhang Shiwu, Wu Gangzhu: Anti-seismic shedding detection method for building curtain wall panels

1 Scope

This standard specifies the testing principles, testing devices, test pieces, pre-test preparations, testing, and testing results for the anti-seismic shedding of building curtain wall panels And test report: This standard is applicable to laboratory testing for earthquake resistance of building curtain wall panels:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 18250 Classification and detection method of interlayer deformation performance of building curtain wall GB/T 34327 Terminology for building curtain walls

3 Terms and definitions

The following terms and definitions defined in GB/T 34327 and GB/T 18250 apply to this document: 3:1 Fall off falout The phenomenon that the building curtain wall panel or accessories separate and fall from the test piece: Note: Accessories refer to the pressure plate, buckle cover, fasteners, etc: of the fixed panel: 3:2 Damage displacement The minimum displacement of the panel or accessories of the building curtain wall specimen that has visible damage that affects normal use but does not fall off: Note 1: Visible damage includes panel cracks, bonding damage, pressure plate and fastener damage, etc: Note 2: The damage displacement is represented by the symbol Δc: 3:3 Falout displacement The minimum displacement of the building curtain wall specimen panel or accessories falling off: Note: The falling displacement is represented by the symbol Δf:

4 Detection principle

The dynamic loading device is used to simulate the inter-layer deformation of the main structure caused by the seismic load: Under the specified frequency and displacement conditions, check Test the resistance of the panel and accessories of the curtain wall to damage and fall off:

5 Detection device

5:1 Composition The testing device should consist of a test piece mounting frame (including support frame, fixed beam, movable beam, sliding device, etc:), dynamic loading device, displacement measurement
......
Image