GB/T 38888-2020 English PDFUS$859.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 38888-2020: Performance and calibration methods for data acquisition software Status: Valid
Basic dataStandard ID: GB/T 38888-2020 (GB/T38888-2020)Description (Translated English): Performance and calibration methods for data acquisition software Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N22 Classification of International Standard: 17.220.20 Word Count Estimation: 46,455 Date of Issue: 2020-06-02 Date of Implementation: 2020-12-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 38888-2020: Performance and calibration methods for data acquisition software---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Performance and calibration methods for data acquisition software ICS 17.220.20 N22 National Standards of People's Republic of China Performance and calibration method of data acquisition software 2020-06-02 release 2020-12-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee ContentsForeword Ⅲ Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions, symbols and abbreviations 1 3.1 Terms and definitions 1 3.2 Symbols and abbreviations 2 4 General performance requirements of test software 3 4.1 Test procedures and measurement uncertainty estimation 3 4.2 General requirements for ADM 3 4.3 Description of parameters 4 4.4 Test methods for measurable parameters 6 5 Hardware function calibration 18 5.1 General 18 5.2 Built-in calibration information 18 5.3 General measurement of hardware adjustment 19 5.4 Self-tuning hardware 19 6 Software calibration method 19 6.1 General 19 6.2 Calibration Application Programming Interface (API) 19 6.3 Self-calibration method 20 6.4 External calibration method 20 7 Calibration procedures 20 Appendix A (Normative Appendix) Pseudo-code and numerical examples for static testing by Method B 21 Appendix B (informative appendix) ADM features 34 Appendix C (informative appendix) Modular DAQ system uncertainty calculation example 39ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some content of this document may involve patents. The issuer of this document does not assume responsibility for identifying these patents. This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Electrical Engineering Standardization Technical Committee (SAC/TC104). This standard was drafted by. Harbin Institute of Electrical Instrument Co., Ltd., State Grid Shandong Electric Power Research Institute, State Grid Jiang Electric Power Research Institute of Jiangsu Electric Power Co., Ltd., Dandong Huatong Measurement and Control Co., Ltd., Xiamen Yixi Intelligent Technology Co., Ltd., State Grid Sichuan Province The measurement center of the power company, the measurement center of Yunnan Power Grid Co., Ltd., and the Heilongjiang Provincial Electrical Instrument Engineering Technology Research Center Division, Zhejiang Chentai Technology Co., Ltd., State Grid Tianjin Electric Power Company Electric Power Research Institute, Shenzhen Jiangji Industrial Co., Ltd., Shenzhen Kelu Electronic Technology Co., Ltd., Xu Ji Group Co., Ltd., Shenzhen Xinglong Technology Co., Ltd., Huali Technology Co., Ltd. Company, State Grid Sichuan Electric Power Research Institute, State Power NARI Technology Co., Ltd., Zhejiang Wansheng Intelligent Technology Co., Ltd. Company, Hangzhou Xili Intelligent Technology Co., Ltd., Xi'an Jiuxinchang Internet of Things Technology Co., Ltd. The main drafters of this standard. Jiang Bin, Zhao Bin, Chen Wenxin, Wang Qing, Han Guiju, Zhou Chao, Liu Haibo, Lin Hongsong, Zhang Xiang, Shen Xin, Gao Ronghui, Guo Chuang, Lv Jin, Duan Feng, Hu Qingbo, Wang Yitong, Yan Yaofeng, Huang Jianzhong, Zeng Shitu, Zhao Zhihui, Wang Kai, Li Zhaogang, Li Ke, Duan Chunfang.IntroductionFully automatic measurement systems have been widely used in manufacturing testing, research and various fields involving measurement. Measurement automation is widely implemented Data sharing, inter-instrument communication and remote measurement control. Multifunctional data acquisition equipment (DAQ) meets these measurement needs. DAQ Relying on standard computer technology enables measurement system developers to make full use of open computer standards. The measurements made by DAQ are Accurate and traceable. To ensure measurement integrity, not only the standards for the measurement hardware, but also the software system for the calibration hardware Set standards. Performance and calibration method of data acquisition software1 ScopeThis standard specifies the performance characteristics and calibration methods of data acquisition software. This standard covers. ---DAQ manufacturers provide minimum specifications that describe the performance of DAQ's analog-to-digital conversion module (ADM); ---Standard test strategy used to verify the minimum specification requirements; ---Minimum calibration information required by ADM stored on DAQ; ---The minimum calibration software requirements for external calibration and self-calibration of DAQ ADM. This standard applies to DAQ for low-frequency signal conversion. Examples. low-frequency signals applied in equipment control, vibration measurement, vibration diagnosis, acoustics, ultrasonic measurement, temperature measurement, pressure measurement, power electronics measurement, etc. Number conversion.2 Normative referencesThe following documents are essential for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document. GB/T 27025-2008 General requirements for the ability of testing and calibration laboratories (ISO /IEC 17025.2005, IDT) ISO /IEC GUIDE98-3.2008 Uncertainty in measurement Part 3.Guide for the representation of uncertainty in measurement (Uncertainty of measurement-Part 3.Guidetotheexpressionofuncertaintyinmeasurement) IEC 60748-4.1997 Semiconductor device integrated circuits Part 4.Interface integrated circuits (Semiconductordevices- Integratedcircuits-Part 4.Interface integrated circuits) IEC 60748-4-3.2006 Semiconductor device integrated circuits Part 4-3.Interface integrated circuit analog/digital converter (ADC) Kinetics Standard (Semiconductordevices-Integratedcircuits-Part 4-3.Interfaceintegratedcir- cuits-Dynamiccriteriaforanalogue-digitalconverters(ADC)) 3 Terms and definitions, symbols and abbreviations 3.1 Terms and definitions The following terms and definitions apply to this document. 3.1.1 Analogue to digital module analoguetodigitalmodule Analog input for multi-function data acquisition equipment. 3.1.2 Application program interface Standardized subprogram or function set and the parameters that the program can call. Application program interface permitting program for data acquisition equipment Staff used to interact and control the operation of the equipment. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 38888-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 38888-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 38888-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38888-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |