GB/T 34961.3-2017: Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 34961.3-2017979 Add to Cart 4 days Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling Valid

Similar standards

CNCA C09-01   GB/T 38668   GB/T 37720   GB/T 34961.4   GB/T 18233.4   GB/T 34961.2   

Basic data

Standard ID: GB/T 34961.3-2017 (GB/T34961.3-2017)
Description (Translated English): Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: L65
Classification of International Standard: 35.200
Word Count Estimation: 49,453
Date of Issue: 2017-11-01
Date of Implementation: 2018-05-01
Regulation (derived from): National Standard Announcement 2017 No. 29
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34961.3-2017: Information technology -- Implementation and operation of customer premises cabling -- Part 3: Testing of optical fibre cabling


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Information technology-Implementation and operation of customer premises cabling-Part 3. Testing of optical fiber cabling ICS 35.200 L65 National Standards of People's Republic of China Implementation and Operation of Information Technology Users' Building Cluster Cables Part 3. Fiber Optic Cable Testing Informationtechnology-Implementation and operating of customer premisioncabling- Part 3.Testingofopticalfibrecabling (ISO /IEC 14763-3.2014, IDT) Posted.2017-11-01 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ Introduction IV 1 Scope 1 2 Normative references 1 3 Terms, definitions and abbreviations 2 3.1 Terms and definitions 2 3.2 Abbreviations 4 3.3 symbol 5 4 Compliance 5 5 General requirements 6 5.1 Test System 6 5.2 Reference Measurement and Calibration 6 5.3 Environmental conditions 6 5.4 archive record 7 6 test equipment 8 6.1 LSPM 8 6.2 OTDR 8 6.3 Test Jumpers and Adapters 9 6.4 MMF transmission mode distribution 12 6.5 SMF launch conditions 13 7 test equipment 13 8 tested cabling - channel and permanent link 13 8.1 Overview 13 8.2 Reference Plane 13 8.3 Measurement wavelength 14 8.4 Measurement direction 14 9 has been installed cable test 14 9.1 Attenuation 14 9.2 propagation delay 19 9.3 Length 20 10 has been installed cabling cable assembly test 20 10.1 cable attenuation 20 Decay between local and remote test interfaces 22 10.3 Connection Hardware Decay 23 10.4 Return Loss of Connecting Hardware 24 10.5 fiber length 25 10.6 Jumper attenuation 27 Inspection of cabling and cabling components 11.1 Optical Fiber Continuity 28 11.2 Cable polarity 28 11.3 cable length 28 11.4 Fiber end face inspection 28 11.5 fiber core size 28 Appendix A (Normative) Testing multimode fiber optic cable launch mode conditions 29 Appendix B (Normative) Connector Visual Inspection Guidelines 30 Appendix C (Informative) Optical Time Domain Reflectometer 31 Appendix D (Normative) Test and replacement jumper wire inspection and testing 35 Appendix E (Normative) Enhanced link and channel attenuation three jumpers and single jumper reference method 37 Appendix F (Informative) Quality Planning 38 Appendix G (informative) Example of calculation of channel and per-link limits 40 Appendix H (informative) Optical fiber connector cleaning and inspection 42 Reference 43

Foreword

GB/T 34961 "information technology user building cabling implementation and operation" includes the following sections. --- Part 1. Management; --- Part 2. Planning and installation; --- Part 3. Optical fiber cable test; --- Part 4. End-to-end link test. This section GB/T 34961 Part 3. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method is equivalent to using ISO /IEC 14763.3.2014 "information technology user building cabling implementation and operation Part 3. Fiber Optic Cable Testing "and ISO /IEC 14763.3.2014 Technical Corrigendum 1.2015. The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows. --- GB/T 18233-2008 Information technology users building general cabling (ISO /IEC 11801.2002, IDT) --- GB/T 29269-2012 Information Technology Residential Common Cable (ISO /IEC 15018.2004, IDT) This standard made the following editorial changes. --- Removed "ffs (to be studied)" content. This standard directly into ISO /IEC 14763.3.2014/Technical Corrigendum 1.2015 content, the corresponding provisions of the margin outside the margin The position is marked by a vertical double line (‖). Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This part of the National Information Technology Standardization Technical Committee (SAC/TC28) and focal point. This section drafted by. China Electronics Standardization Institute, Shenzhen Special Equipment Safety Inspection Institute, Shenzhen 赛 West Information Technology Co., Ltd., Chengdu Corning Cable Co., Ltd. Shanghai Optical Cable System Branch, Love Kosovo Communication Technology (Beijing) Co., Ltd., Wuxi Network Industry Research Institute, Xi'an Kaiyuan Electronic Industrial Co., Ltd., Shandong Province Computing Center (National Supercomputing Jinan Center). The main drafters of this section. Yang Hong, Ma wilderness, Tan Jianjun, Li Min, Yu Hui, Sun Xuerui, Wang Ruru, Chen Shuyi, Yuqin, Fang Yi, Lin Feng, Zhao Xiangyang, Sun Xu, Li Gang, Feng Zhenggan, Zhou Mingle.

Introduction

This section is one of the four existing standards supporting ISO /IEC 11801 and other cabling standards. Figure 1 shows this part of the ISO /IEC 11801, other cabling international standards and cabling related standards. Figure 1 standard relationship diagram ISO /IEC 14763-3 specifies the inspection and testing procedures for optical fiber cabling as well. a) Conforming to the cabling standards for buildings such as ISO /IEC 11801, ISO /IEC 24764, ISO /IEC 24702 and ISO /IEC 15018 Required fiber optic cabling design; and b) Fiber optic cable installation according to ISO /IEC 14763-2 requirements and recommendations. Users in this section should be familiar with the relevant building group cabling standards and ISO /IEC 14763-2. Each installed quality plan should clearly define the acceptance test and sampling level it chooses. Quality plan requirements and recommendations in ISO /IEC 14763-2 stipulated. Note. JTC1/SC25, in cooperation with IEC /TC86, is currently studying a totalization model to estimate as expressed in the ISO /IEC 11801 reference implementation Overall uncertainty. Once this model has been validated, it can be incorporated into this section by way of an amendment to eliminate the current designation "ffs" (to be studied) Terms. Implementation and Operation of Information Technology Users' Building Cluster Cables Part 3. Fiber Optic Cable Testing

1 Scope

GB/T 34961 provisions of this part of ISO /IEC 11801, ISO /IEC 24764, ISO /IEC 24702 and ISO / IEC 15018 and other building cabling standards designed fiber cabling system for testing methods. These methods refer to the existing standards-based The rules.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. ISO /IEC 11801 information technology users building general cabling (Informationtechnology-Genericcablingfor customerpremises ISO /IEC 15018 Information Technology Generic cabling (Informationtechnology-Genericcablingforhomes) ISO /IEC 24702 Information Technology - Genericcabling- Industrialpremises) ISO /IEC 24764 Information Technology-Genericcabling systemsfordatacentres ISO /IEC 14763-2 Information technology - User cabling operation and implementation - Part 2. Planning and installation (Informationtechnology-Implementation and operating of customer premvisioncabling-Part 2.Planningand instalationl) International Electrotechnical Vocabulary, Chapter 731. Optical fiber communications (IEC 60050-731, International electrotechnicalvocabulary-Chapter731.Opticalfibrecommunication) IEC 60825-2 Laser Product Safety Part 2. Optical Communication Systems [Safetyoflaserproducts-Part 2.Safety of optical fiber communications systems (OFCS)] IEC 60874-14-3 Fiber Optic Cable Connectors Part 14-3. SC Type Fiber Optic Adapter (Single Mode) for Single Mode Fiber Details Fine Specifications (Connectors for optical fiber and parts-Part 14-3. Dedicated Specification for fibreoptic adapter (simplex) typeSCforsingle-modefibre) IEC 60874-19-1 Optical fiber cable connectors Part 19-1. Types SC-PC terminated on multimode fiber types A1a, A1b Fiber Jumper Connectors Detail Specification [Connectorsforopticalfibresandcables-Part 19-1.Fibreopticpatchcord- connectortypeSC-PC (floatingduplex) standardterminatedonmultimodefibretypeA1a, A1b- Details] IEC 61280-1-4 Fiber Optic Communication Subsystem Testing Procedures Part 1-4 General Purpose Communication Subsystem Measurements of light flow around sources (Fibreopticcommunicationsubsystemtestprocedures-Part 1-4. General Communications Engineers- tems-Lightsourceencircledfluxmeasurementmethod) IEC 61280-4-1, Optical fiber communication subsystem test procedures - Part 4-1 - Optical fiber line and link multimode fiber line attenuation test (Fibreoptic communicationsubsystemtestprocedures-Part 4-1 .Cableplantandlinks -Multimode fiber-opticcableplantattenuationmeasurement)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 34961.3-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 34961.3-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 34961.3-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 34961.3-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.