GB/T 32277-2015 English PDFUS$399.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32277-2015: Test method for instrumental neutron activation analysis (INAA) of silicon Status: Valid
Basic dataStandard ID: GB/T 32277-2015 (GB/T32277-2015)Description (Translated English): Test method for instrumental neutron activation analysis (INAA) of silicon Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H17 Classification of International Standard: 77.040 Word Count Estimation: 19,191 Date of Issue: 2015-12-10 Date of Implementation: 2017-01-01 Regulation (derived from): National Standard Announcement 2015 No.38 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 32277-2015: Test method for instrumental neutron activation analysis (INAA) of silicon---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Test method for instrumental neutron activation analysis (INAA) of silicon ICS 77.040 H17 National Standards of People's Republic of China Instrumental neutron activation analysis of silicon test methods Issued on. 2015-12-10 2017-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard equipment by the National Standardization Technical Committee and the semiconductor material (SAC/TC203) and National Semiconductor Equipment and Materials Standards Materials Branch of the Technical Committee (SAC/TC203/SC2) jointly proposed and managed. This standard was drafted. Leshan Electric Tianwei Silicon Technology Co., Ltd., China Institute of Atomic Energy, the new shares have a special energy Limited. The main drafters of this standard. Li Zhiwei Zhang Yadong, Zhang, Yao Shu, silver wave, Qiu Yanmei.IntroductionNeutron activation analysis (NAA) is capable of a variety of materials of various elements of high sensitivity quantitative and qualitative analysis. special Notably in the semiconductor industry, it is specified raw materials (for growing semiconductor grade monocrystalline silicon wafers and for analysis and evaluation of high-purity polysilicon Material) trace element contamination. PV industry, the growth of the silicon raw material demand led to more large-scale polysilicon production and purification of various silicon atoms Research and development of alternative materials. Produced by these methods of silicon material in the current literature generally referred to as solar grade silicon, and having a plurality Shapes, such as a lump, powder and granular. With the expansion of polysilicon and solar grade silicon production scale, quality control should also be strengthened, and instrumental neutron activation analysis (INAA) is One alternative method. The method of instrumental neutron activation analysis is a direct implementation of the irradiated samples analyzed, compared with the traditional radiochemistry Neutron activation analysis (RNAA) To irradiated sample chemical separation to remove interfering substances to be tested or concentrated radioactive isotopes Su. Currently, some laboratories using different neutron source, irradiation conditions, electronic equipment and sample preparation methods, to achieve the instrumental neutron activation points Analysis, and used in various forms, types of silicon samples. Instrumental neutron activation analysis of silicon standardized analytical methods will eliminate between Difference, so as to establish a common reference method of analysis. Instrumental neutron activation analysis of silicon test methods1 Scope1.1 standard specifies instrumental neutron activation analysis of silicon materials testing methods. Instrumental neutron 1.2 This standard applies to chemical vapor deposition method or a method for purifying metallurgical silicon produced by activation analysis. Analysis of samples can be Be monocrystalline, polycrystalline, and polycrystalline form may be a powder, a granule, or bulk silicon. 1.3 This standard applies to macroscopic material composition analysis. As an additional test method according to the sample preparation, and in sample extraction, transport And preparation process to avoid surface contamination, but also realize the sample surface or near-surface area analysis. 1.4 Test method applies only to Appendix A thermal neutron or epithermal neutron activation analysis of trace elements listed. 1.5 test method does not apply to the amorphous silicon thin-film polycrystalline silicon thin film analysis, or microcrystalline silicon thin film. For by artificially high doping concentration Laid Silicon sample special elements do not belong to the scope of this test method, but doping checked for safety, detection limits and the minimum waiting time tw0 After impact, the test method may also be applicable. 1.6 This test method is used to analyze a wide range of trace elements (see Appendix A). Generally, the irradiation time of the sample should be higher than 31Si decay lifetime Long, and the like should be generated after irradiation 31Si fully decay analysis can be implemented.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 620-2011 Chemical reagent hydrofluoric acid (ISO 6353-3. 1987, NEQ) GB/T 626-2006 Chemical Reagent nitrate (ISO 6353-2. 1983, NEQ) GB/T 11446.1-2013 electronic grade water GB/T 14264 semiconductor material terms GB 18871 ionizing radiation protection and safety of radiation sources basic standards GJB2253A-2008 nitrogen and liquid nitrogen application security guidelines "Hazardous Chemicals mandatory national standards Implementation Manual" ISO 11929.2010 ionizing radiation measurements characteristic limits (decision threshold, detection limit and the limit of the confidence interval) of the basic measurement Principles and Applications [Determinationofthecharacteristiclimits (decisionthreshold, detectionlimitandlimitsof theconfidenceinterval) formeasurementsofionizingradiation-Fundamentalsandapplication] 3 Terms, definitions, abbreviations 3.1 Terms and Definitions GB/T 14264 and defined by the following terms and definitions apply to this document. 3.1.1 Environmental background ambientbackground In addition to sample radiation generated by the radiation detector records. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32277-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 32277-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 32277-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32277-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |