Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 29724-2013 English PDF

US$259.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 29724-2013: Energy monitoring for solar water heating system
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29724-2013259 Add to Cart 3 days Energy monitoring for solar water heating system Valid

Similar standards

GB/T 29319   GB/T 33589   GB/T 33599   GB/T 45310   GB/T 45313   GB/T 45234.302   

Basic data

Standard ID: GB/T 29724-2013 (GB/T29724-2013)
Description (Translated English): Energy monitoring for solar water heating system
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F12
Classification of International Standard: 27.010; 27.160
Word Count Estimation: 11,196
Quoted Standard: GB/T 7665-2005; GB/T 12936-2007; GB 17167; GB/T 19582; GB/T 19565; GB/T 20095-2006; CJ 128-2007; CJ/T 188; DL/T 645; ISO 9488-1999
Regulation (derived from): National Standards Bulletin No. 19 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies: solar hot water systems for energy and other parameters for energy measurement and monitoring methods requirements. This standard applies to: a single storage tank effective volume greater than 0. 6 m3, work properly heat the work

GB/T 29724-2013: Energy monitoring for solar water heating system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Energy monitoring for solar water heating system ICS 27.010; 27.160 F12 National Standards of People's Republic of China Solar hot water system energy monitoring Issued on. 2013-09-18 2014-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the National Standardization Technical Committee of solar energy (SAC/TC402) and focal points. This standard is drafted by. Beijing Bo Creative Energy Technology Co., Ltd. Shenzhen Pengsangpu Solar Co., Ltd., China Agricultural Village Energy Industry Association Solar thermal Professional Committee, China National Institute of Standardization, Sunshine Solar Co., Ltd., Beijing Tsinghua sun Light Energy Development Co., Ltd., Beijing Solar Temple Industrial Co., Ltd. Himin solar energy, solar energy has sun rain Ltd., Shandong Li Norit New Energy Co., Ltd., Beijing Four Seasons song Mu Solar Technology Group Co., Ltd., Jiangsu Huayang Solar has Limited, Beijing Solar Energy Research Institute Group Co., Ltd., Jiangsu per liter Solar Group Co., Ltd. Jiangsu brilliant solar limited stock The company, Hefei Meiling Solar Energy Technology Co., Ltd., Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd., Zhejiang gorgeous than the electron Technology Co., Ltd., Hebei source of solar energy Ltd., Shenyang Tupper Solar Water Heater Co., Ltd., the national solar water heater Quality Supervision and Inspection Center (Beijing), the National Solar Water Heater Quality Supervision and Inspection Center (Wuhan), National Solar water heaters quality supervision Governor Inspection Center (Kunming). The main drafters of this standard. Tangxuan, Qiuren Zheng, Luo Zhentao, Jia Tieying, Zhao Feng, Huozhi Chen, Huang Zhelin, Cheng Cuiying, Zhang Lifeng, Xu Youcheng, Ma Guangbo, Dou Jianqing, Huang Yongwei, Zhao Wenzhi, WU Dao Yuan, Tang Yijun, any agency Ming, Jiang Lijun, pay deposit that, Licheng Bin, Guo Baoan, He Tao, Cheng Yan, Chen learned first. Solar hot water system energy monitoring

1 Scope

This standard provides for the solar water heating system for heat and energy metering and other parameters monitoring methodology requirements. This standard applies to a single storage tank effective volume of more than 0.6m3, during normal operation heat the working fluid is liquid solar hot water systems. It does not apply to hot water systems by more than one compact solar water heater composed.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 7665-2005 sensor generic term GB/T 12936-2007 Solar Thermal applications - Terminology GB 17167 energy use per unit of energy measuring instruments and General Manager GB/T 19582-based Modbus protocol for industrial automation network specification GB/T 19565 pyranometer GB/T 20095-2006 solar hot water system of evaluating the performance specifications CJ128-2007 Calorimeter CJ/T 188 household meters data transmission technology conditions DL/T 645 multifunction meter communication protocol ISO 9488.1999 Solar Glossary (Solarenergy-Vocabulary)

3 Terms and Definitions

GB/T 7665-2005, GB/T 12936-2007 and ISO 9488.1999 define the following terms and definitions apply to this article Member. For ease of use, repeat the following list of GB/T 12936-2007 of certain terms and definitions. 3.1 Solar water heating systems solarwaterheatingsystem Solar water heating system as a heat source. 3.2 At the same time out of the water system synchronoussystemwithcoldwaterfeed-inandhotwateroutput Cold water and hot water for simultaneous users of solar water heating systems, such as pressurized water system, or through a heat exchanger and storage tank Heat the water system. 3.3 Non-simultaneous out of the water system asynchronoussystemwithcoldwaterfeed-inandhotwateroutput Cold water and hot water for the user is not simultaneous solar hot water systems, such as an open system, non-pressure water. 3.4 User line loop hotwaterrecirculation Can recycle loop, hot water can be circulated between the storage tank and piping system of water users formed between the storage tank and piping water users.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29724-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29724-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29724-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29724-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.