GB/T 29160-2012 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29160-2012: Test methods for solar-plus-supplementary water heating system (tank capacity more than 0.6m3) Status: Valid
Basic dataStandard ID: GB/T 29160-2012 (GB/T29160-2012)Description (Translated English): Test methods for solar-plus-supplementary water heating system (tank capacity more than 0.6m3) Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F12 Classification of International Standard: 27.160 Word Count Estimation: 9,939 Quoted Standard: GB 3100; GB/T 12936; GB/T 18713; GB/T 19141; GB/T 19565; GB/T 20095; GB/T 29158; ISO 9488-1999 Regulation (derived from): National Standards Bulletin No. 41 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the auxiliary energy with solar water heating system (tank volume greater than 0. 6m3) performance test methods. This standard applies to a single tank effective volume greater than 0. 6m3 auxiliary energy with solar hot water syst GB/T 29160-2012: Test methods for solar-plus-supplementary water heating system (tank capacity more than 0.6m3)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Test methods for solar-plus-supplementary water heating system (tank capacity more than 0.6m3) ICS 27.160 F12 National Standards of People's Republic of China Solar water heating system with auxiliary energy (Tank volume greater than 0.6m3) Performance Test Method Issued on. 2012-12-31 2013-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the National Standardization Technical Committee of solar energy (SAC/TC402) and focal points. This standard is drafted by. Solar Energy Research Institute, Yunnan Normal University, Shenzhen Jiapu-Solar Co., Ltd., Nanjing North Purcell Solar Engineering Ltd., Sunshine Solar Co., Ltd., Jiangsu Huayang Solar Co., Ltd., Zhejiang Branch Horvat saving Technology Co., Ltd., Jiaxing City, Tongji sunshine new energy Co., Ltd., Nanjing Vantage New Energy Co., Ltd., with Yunnan Tin Lok Solar Limited Division Chuzhou Yangtze New Materials Technology Co., Ltd. Himin, Tempe New Energy Technology Co., Ltd., Beijing for Fishman Thermal Technology Co., Ltd., Guangdong million and the new Electric Co., Ltd., Yunnan built Bo Engineering Co., Ltd., Beijing Creative Bo ENERGY Technology Co., Ltd., Zhejiang unlimited new energy Co., Ltd., Jiangsu Quartet Boiler Co., Ltd., Yanzhou Crystal Crown Glass Co., Ltd., China Standard Of the Institute. The main drafters of this standard. Chen Xue-xian, SUN help Cong, Liu really, Xiao L, Huang Yongwei, Hanguang Tian, \u200b\u200bpipe Jin, Xue Jiubing, Zhang Xin, Jialei Zhang, Liu Zhiqiang, seong, Zhao, Wang small column, Liuxue Fen, Zouhuai Song, Fangzhao Min, Duan Xu Qiang, Zhu Qingping. Solar water heating system with auxiliary energy (Tank volume greater than 0.6m3) Performance Test Method1 ScopeThis standard specifies a solar water heating system with auxiliary energy (tank volume greater than 0.6m3) performance test methods. This standard applies to single tank effective volume of more than 0.6m3 with auxiliary energy solar hot water systems. This standard does not apply to solar hot water heat pump heating system.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated edition applies to this file. For undated references, the latest edition (including any amendments) applies to this document. GB 3100 International System of Units and Its Application GB/T 12936 solar thermal terms GB/T 18713 solar hot water system design, installation and engineering acceptance GB/T 19141 domestic solar water heating systems GB/T 19565 pyranometer GB/T 20095 solar hot water system of evaluating the performance specifications Solar hot water systems GB/T 29158 with auxiliary energy (tank volume greater than 0.6m3) Technical Specifications ISO 9488.1999 Solar Glossary (Solarenergy-Vocabulary)3 Terms and DefinitionsGB 3100, GB/T 12936, GB/T 18713, GB/T 20095, GB/T 29158 and ISO 9488.1999 definition of terms and Definitions apply to this document.4 Symbols and unitsThe following symbols and units apply to this document. Total contour solar collector area lighting, solar hot water system unit square (m2). Ac. cpw. Water heat capacity at constant pressure, in units of kilojoules per kilogram degree Celsius [kJ/(kg · ℃)]. CHP. solar water heating system with auxiliary energy co-operation of the thermal coefficient of performance, dimensionless. Ed. auxiliary energy when electric heating system, electric energy consumption during the performance test units of megajoules (MJ). H. solar collectors flat daily amount of solar radiation port where the lighting units of megajoules per square meter (MJ/m2). Mz. the auxiliary energy for the direct steam heating systems, enter the amount of steam during the performance test, in kilograms (kg). ρw. density of water, in kilograms per cubic meter (kg/m3). Qf. During the combined operation of thermal performance test systems, auxiliary energy for heat heating system, in units of megajoules (MJ). Qh. auxiliary energy or heat transfer station when the boiler heating system, enter the amount of heat pipe network performance during the test, expressed in megajoules (MJ). ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29160-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 29160-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 29160-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29160-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |