GB 19510.10-2009 English PDFUS$374.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19510.10-2009: Lamp controlgear -- Part 10: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) Status: Valid GB 19510.10: Historical versions
Basic dataStandard ID: GB 19510.10-2009 (GB19510.10-2009)Description (Translated English): Lamp controlgear -- Part 10: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) Sector / Industry: National Standard Classification of Chinese Standard: K74 Classification of International Standard: 29.140.99 Word Count Estimation: 19,137 Date of Issue: 2009-10-15 Date of Implementation: 2010-12-01 Older Standard (superseded by this standard): GB 19510.10-2004 Adopted Standard: IEC 61347-2-9-2003, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2009 (No. 151 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Chinese standard applies to high-pressure mercury lamp, low pressure sodium lamp, high pressure sodium and metal halide lamps with ballast specific requirements. This standard applies to adopt the following 50Hz or 60Hz 1000 V AC ballast, its support of the discharge lamp rated power, size and characteristics should meet IEC 60188, IEC 60192, IEC 60662 and IEC 61167 requirements. This standard applies to complete ballasts and their component parts, for example: reactors, transformers and capacitors. Thermally protected ballasts special requirements, see Appendix B. GB 19510.10-2009: Lamp controlgear -- Part 10: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Lamp controlgear.Part 10. Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) ICS 29.140.99 K74 National Standards of People's Republic of China GB 19510.10-2009/IEC 61347-2-9.2003 Replacing GB 19510.10-2004 Lamp control Part 10. discharge lamps (excluding fluorescent lamps) Particular requirements for ballasts (IEC 61347-2-9.2003, Lampcontrolgear- Part 2-9. Particularrequirementsforbalastsfordischargelamps (Excludingfluorescentlamps), IDT) Posted 2009-10-15 2010-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 2 General requirements 4.1 2 capacitors and other components 4.2 thermally protected ballast 2 5 Test Description 2 6 Category 2 7 Flag 2 7.1 Mandatory Signs 2 7.2 Supplementary sign 2 7.3 Other marks 3 8 accidental contact with live parts of the measures to prevent 3 9 Terminal 3 10 grounding device 3 11 Moisture resistance and insulation 3 12 Dielectric strength 3 Heat winding 13 Test 3 Thermal limit of 14 ballast 3 15 high-voltage pulse test 6 16 Fault Status 6 17 Structure 6 18 creepage distances and clearances 6 19 Screws, current-carrying parts and connections 7 20 heat, fire and resistance to tracking 7 21 corrosion 7 22 no-load output voltage 7 Appendix A (normative) test to determine whether a conductive part is a live part may cause an electric shock. 8 Particular requirements for 8 Appendix B (normative) control device for thermally protected lamp Particular requirements 8 Annex C (normative) with thermal protector electronic control unit lamp Annex D (normative) heating test control apparatus for thermally protected lamp of claim 8 Annex F (normative) anti-convection air chamber 8 Derivation of Annex G (normative) values of pulse voltages 8 Annex H (normative) Test 8 Selection Annex I (normative) varistors 9 Appendix J (informative) Description of ballast temperature 10 Supplementary requirements Annex K (normative) double or reinforced insulation of built-in magnetic ballasts 13 GB 19510.10-2009/IEC 61347-2-9.2003ForewordAll technical content in this section is mandatory. GB 19510 "Lamp control" is divided into 14 parts. --- Part 1. General requirements and safety requirements; --- Part 2. starting devices (other than glow starters) - Particular requirements; --- Part 3. Tungsten with AC/DC buck converter electronic Particular requirements; --- Part 4. Particular requirements for the exchange of electronic fluorescent ballasts; --- Part 5. Particular requirements for dc supplied electronic ballasts for general lighting of; --- Part 6. Particular requirements for dc public transport lighting ballasts; --- Part 7. DC electronic ballasts for aircraft lighting Particular requirements; --- Part 8. DC electronic ballasts for emergency lighting Particular requirements; --- Part 9. Particular requirements for ballasts for fluorescent lamps; --- Part 10. discharge lamps (excluding fluorescent lamps) with the special requirements of the ballast; --- Part 11. high frequency cold start tubular discharge lamps (neon) Specific requirements for electronic exchange and the frequency converter; --- Part 12. Particular requirements for lamps miscellaneous electronic circuits; --- Part 13. discharge lamps (excluding fluorescent lamps) or AC supplied electronic ballasts for special requirements; Part --- Article 14. LED module with special requirements for dc or ac electronic control device. This is Part 10 GB 19510's. This section should be used in conjunction with the GB 19510.1. It was only after the corresponding provisions of GB 19510.1 supplement or modify the development It made. This section identical with IEC 61347-2-9.2003 (Version 1.1) "Lamp control - Part 2-9. discharge lamps (fluorescent lamps except Outside) the special requirements "for ballasts and revised in 2006, 2 (in English). For ease of use, this section made the following editorial changes. a) "IEC 61347-2-9" to "this Part"; b) Remove the preface IEC 61347-2-9, IEC 61347-2-9 revised introduction; c) The international standard "(note .)" form brackets removed; d) as a decimal by decimal points instead of "and", "."; e) For other international standards referenced it has been adopted as the equivalent of a standard, this part of the country with reference to these national standards Or industry standards instead of the corresponding international standards, and the rest not tantamount to the adoption of a standard for the international standards in this section are Direct reference (see Part 2 of this chapter). This Part replaces GB 19510.10-2004 "General requirements for discharge lamps (excluding tubular fluorescent lamps) ballasts and safety requirements." Compared with some of the major differences between GB 19510.10-2004 this as follows. a) increase the reference in this section 7.1 GB 19510.1 of 7.1r) items requested; b) The GB 19510.10-2004 first column in Table of Contents 1 "and the ballast housing adjacent capacitor." to Table 1 of this section The first column of the content "ballast housing adjacent capacitor, if any (one capacitor and ballast)"; c) an increase in Chapter 22, "no-load output voltage"; d) increase in Appendix K "on the built-in double insulation or reinforced insulation additional requirements of ballast"; e) The 15 "design requirements to work in line with light outer boot device ballast" is changed to "Design requirements for external start Means the lamp ballast work "; GB 19510.10-2009/IEC 61347-2-9.2003 f) The 15.2 "flag" to "identity." This section of the Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix H, Appendices I and K is the norm Appendix Appendix J are informative appendices. This part is proposed by the China National Light Industry Council. This part of the National Electric lighting Standardization Technical Committee (SAC/TC224) centralized. This section is drafted. Fujian JK Yaming Electric Co., Ltd., the National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Foshan Huaquan Electric Lighting Co., Ltd., Wujiang Huafeng (Huaneng) Electronics Co., Ltd., Jiangsu YASHIPS lighting. The main drafters of this section. Zhang Quan, Zhangyi Peng, Yuan Qi, Yang Chi District, Ding Buxiong, water Yu Rong, Yan Jinxing, Cooper rights. This section was first released in 1993, the first revision in 2004, this is the second amendment. GB 19510.10-2009/IEC 61347-2-9.2003IntroductionThis section and the various parts constituting the GB 19510.2 ~ GB 19510.14 GB 19510.1 at the time of any reference to the terms of the Order to implement the terms and scope of the test, but also provides the necessary additional requirements. GB 19510.2 ~ GB 19510.14 each Part is separate, and do not refer to each other. If this section by "a section in accordance with GB 19510.1-2009 requires," this sentence to refer to the GB 19510.1-2009 A provision requirements, the meaning of this statement is in accordance with all the requirements of this provision, but obviously does not apply to GB 19510.2 ~ Except for the contents of the control device GB 19510.14 specific type of lamp. GB 19510.10-2009/IEC 61347-2-9.2003 Lamp control Part 10. discharge lamps (excluding fluorescent lamps) Particular requirements for ballasts1 ScopeThis part of GB 19510 specifies the requirements for special high-pressure mercury lamp, low pressure sodium, high pressure sodium and metal halide lamp ballasts. This section applies to the use of AC 50Hz or 60Hz1000V less ballast, instead of supporting the rated power of the discharge lamp, Dimensions and characteristics shall comply with IEC 60188, IEC 60192, IEC 60662 and IEC 61167 of. This section applies to complete ballasts and their component parts, such as. reactors, transformers and capacitors. Thermally protected ballast special Specific requirements in Appendix B. Note 1. Certain types of discharge lamps require a trigger. Note 2. The fluorescent lamp ballasts see GB 19510.9. Performance requirements are given in GB/T 15042 in.2 Normative referencesThe following documents contain provisions which, through reference in this Part of GB 19510, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. This part of the normative GB 19510.1-2009 Chapter 2 of the reference document as well as the following normative references. GB/T 15042 lamp for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements for ballasts (GB 15042-2009, IEC 60923.2006, IDT) Part 1 GB 19510.1-2009 lamp control apparatus. General and safety requirements (IEC 61347-1.2007, IDT) Part 2 GB 19510.2 lamp control device. starting devices (other than glow starters) - Particular requirements (GB 19510.2- 2009, IEC 61347-2-1.2006, IDT) IEC 60188 high pressure mercury lamp IEC 60192 Low pressure sodium IEC 60662 HPS IEC 61167 metal halide lamps3 Terms and DefinitionsGB determined following terms and definitions 19510.1-2009 Chapter 3 apply to this section. 3.1 By the manufacturer under the conditions specified in this section to determine the temperature rise. NOTE. Ballast power requirements and installation conditions specified in Annex H. 3.2 Intentionally applied aperiodic transient voltage, this voltage is applied, it should quickly rose to a peak, and then it is usually slow down GB 19510.10-2009/IEC 61347-2-9.2003 To zero. Such pulses are generally two indices and to represent. Note. The term "pulse" and "surge" are different, which is a transient phenomenon grid electrical equipment in the course of arising.4 General requirementsIn accordance with Chapter 4 GB 19510.1-2009 and the following requirements. 4.1 capacitors and other components Mounted in the ballast capacitors and other components shall be in accordance with the relevant standards. 4.2 thermally protected ballast Thermally protected ballasts are specified in Annex B.5 Test DescriptionGB 19510.1-2009 accordance with Chapter 5 as well as the following requirements. 5.1 Type tests shall be carried out on a sample group of eight ballasts submitted for type testing thereof. Wherein the heat for seven ballasts Test, a ballast for all other tests. Heat resistance test on eligibility, see Chapter 13 requirements. For metal halide and high pressure sodium lamp ballasts, but also in accordance with the requirements of Chapter 15. Another six ballast high pressure pulse test It should not be substandard goods inspection, during the test. 5.2 The test shall be carried out under conditions of GB 19510.1-2009 Appendix H prescribed. Typically, each type of ballast to be full Portion of the test. If the number of involved are similar to the ballast, the batch may be tested in each of the rated power of the ballast, or Consultation with the manufacturer, select a representative of the ballast from the batch tested. In the same structure but different properties of a number of ballast When submitting acceptance together, if the manufacturer or other test reports are accepted provided the authority inspection departments, in accordance with the requirements of Chapter 13 As well as the number of samples shown in Appendix E "Unlike 4500 S constant usage of" heat resistance test conducted permits has decreased, even To omit these tests. Category 6 In accordance with Chapter 6 GB 19510.1-2009 requirements.7 logoAs part of the ballast lamps do not have to make signs. For ballasts installed in the lamppost base should be 7.1 and 7.2 All signs and markings listed on the ballast. Signs should comply with GB 19510.1-2009 in 7.2. 7.1 Mandatory Signs Ballast (not including integral ballasts) shall be clearly and durably marked with the following mandatory markings. --- GB 19510.1-2009 in 7.1 a), b), e), f), g) and r content) item; --- Need for ballast and trigger (GB 19510.2) used together, it should be marked on the ballast to withstand the pulse voltage wiring Terminal (terminal device). Note. This flag may take the form of the wiring diagram. But for some high pressure mercury lamp and metal halide lamp using a simple multi-purpose reactance coil ballast In this way you do not have to make signs. 7.2 Supplementary flag In addition to these mandatory flag should also apply to the following content marked on the ballast, or marked on the manufacturer's catalog or similar Specification. --- In 7.1 of GB c 19510.1-2009), h), i), j), k), o), p) and q content) of the item; --- For high pressure sodium or metal halide lamp ballasts. 1) If the maximum peak pulse voltage ballasts can withstand over 1500V, the value should be marked; 2) can be used to match the ballast trigger catalog number; GB 19510.10-2009/IEC 61347-2-9.2003 --- For ballast by more than one independent element constituted shall be marked with the other main element in its current controlling inductive element To parameters; --- For with a separate series capacitor (instead of radio interference suppression capacitor) ballast, repeat marked rated Voltage, capacitance and tolerance; --- For multiple ballast integrally mounted on poles, junction box, marked to prevent overheating of ballasts and associated components to install Suggest. 7.3 Other marks Manufacturers may provide the applicable non-mandatory signs.8 measures to prevent accidental contact with live partsGB 19510.1-2009 accordance with the requirements of Chapter 10.9 TerminalsGB 19510.1-2009 accordance with Chapter 8 requirements. 10 grounding device In accordance with the requirements of GB 19510.1-2009 Chapter 9. 11 Moisture resistance and insulation GB 19510.1-2009 accordance with the requirements of Chapter 11. 12 Dielectric strength In accordance with the requirements of GB 19510.1-2009 Chapter 12. In addition, using a trigger and the pulse voltage is generated in its internal ballast, should also bear the trigger voltage insulator be Dielectric strength test. The following table shows the test voltage (U = operating voltage). ≤4U × 1.414 pulse voltage pulse voltage > 4U × 1.414 Double reinforced insulation 4U + 2750V Upmax/1.414 + 2750V Basic insulation and supplementary insulation 2U + 1000V Upmax/(2 × 1.414) + 1000V Heat test 13 windings GB 19510.1-2009 accordance with the requirements of Chapter 13. Thermal limit of 14 ballasts Its ballast mounting surface should not cause harm their safety temperature. Eligibility Test by 14.1 and 14.2 and GB 19510.1- H. 2009's The tests of 12. 14.1 14.2 When the ballast according to the requirements of the test, the temperature in the normal state and abnormal state test which should not exceed Table 1 It shows the corresponding values. Prior to testing, should be subjected to the following tests and measurements. a) lamp ballasts should enable the normal start and work; b) when necessary, measure the resistance of each winding at ambient temperature. Heating test after the end of the ballast cooled to room temperature, then the ballast shall meet the following requirements. GB 19510.10-2009/IEC 61347-2-9.2003 a) ballast flag is still clearly visible; b) ballast shall withstand Chapter 12 dielectric strength test should not be damaged, the test voltage should be reduced to GB 19510.1- 2009 75% of the value shown in the tables 1, but not less than 500V. Test 14.2 ballast placed under normal conditions. If required, in accordance with the following description of the ballast was placed under abnormal conditions again Source voltage under the value of the flag to verify. For the test under normal conditions, the ballast should work with appropriate lights, where lights should not make the generated heat to the town CURRENT heating impact. If under specified test conditions, the current through the lamp and the lamp current through the reference tolerance same Within range, these lamps can be regarded as an appropriate lamp. For the test under abnormal conditions, the ballast is connected directly to the power supply, while the short circuit across the lamp to simulate in the abnormal state can Ballast shorted line. Note 1. For the inductance coil ballast (simple choke in series with the lamp inductance), allows the manufacturer to decide not to install lights during the test and measurement, but That should be adjusted to the current value at 106% of rated voltage illuminated test. For non-inductive coil ballasts should ensure representative The degree of wear and tear. Note 2. If you need to measure the temperature rise of the ballast winding (non-essential items), should make appropriate ballast and lamp working together at rated supply voltage and rated frequency And then measure the temperature to stabilize. In this case, the inductance coil ballast (simple choke in series with the lamp inductance), test Inspection and measurements can be without lights were installed, but should be adjusted to the current value when the rated supply voltage illuminated test. Table 1 Maximum temperature part The maximum temperature At 100% of rated voltage Normal working At 106% of rated voltage Normal working At 110% of rated voltage Abnormal operation Indicating an abnormal state ballast winding temperature values Ballast housing adjacent capacitor, if (capacitor and ballast Integrally). --- Without temperature flag Various materials components. --- Wood filler phenolic molded parts --- Mineral filler phenolic molded parts --- Urea molded plastic parts --- Melamine molded parts --- Laminating resin bonded paper parts --- Rubber parts --- Thermoplastic material component Note 1. If the material used in the manufacturing method and those listed in the table are not the same, then they should not be higher than the operating temperature of this material has proven allowed temperature. Note 2. When the ballast is operating at its nominal maximum ambient temperature, the temperature should not exceed the values shown in the table. The value in the table is based on ambient temperature of 25 ℃ Obtained. Under normal conditions, a measure of 100% of the rated voltage winding temperature rise is intended to verify the indicated parameters, in order to provide reference for the lighting design and, therefore, Not necessarily be. Only in the ballast signs or catalog when otherwise required for such measurements with. b only possible abnormal state lines for such measurements. Extreme temperatures abnormal winding state should not exceed the number of days and durability test theory More than two thirds of the number of days corresponding to the temperature value (see Table 2 and Table 3). c In addition to the wire insulation to prevent contact with live parts or live parts as a thermoplastic material support should also determine its temperature. test the result Temperature value is used to es......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19510.10-2009_English be delivered?Answer: Upon your order, we will start to translate GB 19510.10-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB 19510.10-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB 19510.10-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB 19510.10-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19510.10-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |