Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 10282-2008 English PDF

US$199.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 10282-2008: Machinery for forestry -- Portable pneumatic fire extinguisher -- Safety code of practice
Status: Obsolete

GB 10282: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 10282-2008199 Add to Cart 2 days Machinery for forestry -- Portable pneumatic fire extinguisher -- Safety code of practice Obsolete
GB 10282-1999199 Add to Cart 2 days Portable pneumatic extinguishers Safety requirements Obsolete
GB 10282-1988RFQ ASK 3 days Portable pneumatic extinguishers--Safety requirements Obsolete

Similar standards

GB 7956.12   GB 7956.6   GB 7956.1   GB/T 10284   GB/T 10283   GB/T 10280   

Basic data

Standard ID: GB 10282-2008 (GB10282-2008)
Description (Translated English): Machinery for forestry -- Portable pneumatic fire extinguisher -- Safety code of practice
Sector / Industry: National Standard
Classification of Chinese Standard: C84
Classification of International Standard: 65.060.80
Word Count Estimation: 5,575
Date of Issue: 2008-12-23
Date of Implementation: 2009-05-01
Older Standard (superseded by this standard): GB 10282-1999
Quoted Standard: GB/T 10280; LY/T 1719
Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard specifies the use of portable pneumatic extinguisher safety requirements. This standard applies to portable pneumatic extinguishers and portable water extinguisher wind.

GB 10282-2008: Machinery for forestry -- Portable pneumatic fire extinguisher -- Safety code of practice


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Machinery for forestry.Portable pneumatic fire extinguisher.Safety code of practice ICS 65.060.80 C84 National Standards of People's Republic of China Replacing GB 10282-1999 Forestry machinery - Portable pneumatic fire extinguisher Safety requirements Posted 2008-12-23 2009-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

Chapter 3 of this standard are mandatory, the rest are recommended. This standard replaces GB 10282-1999 "Portable pneumatic extinguishers safety regulations." This standard compared with GB 10282-1999 main changes are as follows. --- Chapter 1 to add a "wind water and portable extinguishers"; --- Increased in Chapter 2, normative references; --- The 3.1 "General requirements" to "basic requirements" and add wind extinguishing equipment "do not meet the above criteria, the right to refuse Must use "content; --- Added "wind water fire extinguisher job preparation requirements," and so in 3.2; --- Increased in 3.3 "operator according to the actual situation of the scene, to ensure its own security conditions, the choice of wind or wind fire Sprinkler force. "Requirements. This standard by the National Forestry Machinery Standardization Technical Committee and centralized. This standard is drafted by. China Longjiang Forest Industry (Group) Corporation. Participated in the drafting of this standard. James River Forestry Bureau in Heilongjiang Province, Xinglong Forestry Bureau in Heilongjiang Province, Heilongjiang Province, the second set of Forest Inventory and Planning Design Institute, Shaanxi Northwest Forest Machinery Company Limited. The main drafters of this standard. Lu Jing group, Mengxiang Bin, Xu Yonghua, Meng Qingliang, Wang Hua Zhang, Zhang Zhiyi, Liu Lei. This standard replaces the standards previously issued as follows. --- GB 10282-1988, GB 10282-1999. Forestry machinery - Portable pneumatic fire extinguisher Safety requirements

1 Scope

This standard specifies the safety requirements for the use of portable pneumatic extinguisher. This standard applies to portable pneumatic extinguishers and portable water extinguishers wind.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 10280 Forestry machinery - Portable pneumatic fire extinguisher LY/T 1719 forestry machinery - Portable water extinguisher wind 3 - Safety requirements 3.1 Basic requirements 3.1.1 Firefighting equipment non-standard non-team wind extinguishing equipment. Operator found not complying with GB/T 10280 and (or) LY/T 1719 of Wind extinguishing equipment, the right to refuse to use. 3.1.2 The operator should be trained before induction. 3.1.3 The operator should be read carefully before using the fire fighting equipment used by the operating instructions, familiar with its features and controls. 3.1.4 The following persons are not allowed to use fire-fighting equipment. a) minors and the elderly; b) the sick deformed and weak people; c) influence of alcohol or taking stimulants, narcotics person. 3.1.5 The operator at the job site fire, fire should wear protective clothing, protective boots, wearing a fire helmet (protective glasses) and protective gloves. 3.2 Preparation 3.2.1 operator before firefighting operations on the pneumatic extinguisher used (wind water fire extinguisher) to regularly check and found that failure to timely exclude. 3.2.1.1 Electrical system should ensure the normal, no leakage and short circuit. 3.2.1.2 fuel supply system should ensure the smooth flow of oil, no oil leakage. 3.2.1.3 Wind extinguishers shall GB/T 10280 regulations do start test, should smooth start within 30s success. 3.2.1.4 Wind extinguishers shall GB/T 10280 regulations, since the level up, down, left and right tilt 90 ° (carrying fire extinguishers should be front, back, Left and right tilt 45 °) can work properly. 3.2.1.5 As with wind water fire extinguisher, but also to ensure the reservoir and plumbing connections without loosening and leakage, reliable connection, the reservoir strap prison Rely on water quantity standard. 3.2.2 Random alternate fuel shall be specified in the instructions mixing ratio mix evenly loaded into special containers and placed in a cool and safe The whole place. 3.2.3 should be a safe place away from sources of ignition fuel, may not have near the fire, non-smoking. 3.2.4 should use a dedicated container and funnel refueling refueling. 3.2.5 Refueling should be finished immediately wipe the surface residual wind extinguishers. 3.2.6 Tighten the fuel tank cap, flip any wind extinguishers should be no leakage. 3.2.7 Fuel spilled on the ground, the wind extinguishers need to be moved to safe prescription start if refueling. 3.3 firefighting jobs 3.3.1 The operator according to the actual situation of the scene, to ensure its own security conditions, can choose to use wind or wind fire sprinkler. 3.3.2 When extinguishing operations to as a group. 3.3.3 foreign objects into the fan housing should be promptly removed; for the wind water fire extinguisher, to ensure the smooth flow of the water reservoir and pipes. 3.3.4 In the extinguishing process required to add fuel, in addition to compliance with the provisions of 3.2.3 - 3.2.6 should be shut down, as far as possible in the upwind or downwind side Come on. 3.3.5 or went to the scene transitions, pneumatic fire extinguisher fuel tank should be emptied within. 3.3.6 Wind extinguishers for other purposes when the job, according to the relevant safety procedures implemented. 3.4 Maintenance and storage 3.4.1 stop, according to the use and maintenance instructions, cool, dry environment, non-collision, extrusion. 3.4.2 fire extinguisher of the wind should be regularly checked, maintenance and commissioning. 3.4.3 Wind extinguishers long-term storage, should be done. a) exhausted fuel tank and carburetor fuel; b) by the use of specification requirements for maintenance, to reach good condition; check at least once every quarter, starting once; c) packing or storage overhead storage, pay attention to moisture.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 10282-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 10282-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 10282-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 10282-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 10282-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 10282-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.