HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YS/T 568.6-2008 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 568.6-2008: Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of titamium content. Diantipyrylmethane spectrophotometric method
Status: Valid

YS/T 568.6: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 568.6-2008English169 Add to Cart 3 days [Need to translate] Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of titamium content. Diantipyrylmethane spectrophotometric method Valid YS/T 568.6-2008
YS/T 568.6-2006English199 Add to Cart 2 days [Need to translate] (Zirconium, hafnium oxide titanium measuring the amount of (b diantipyrine methane absorption spectrophotometry)) Obsolete YS/T 568.6-2006

PDF similar to YS/T 568.6-2008


Standard similar to YS/T 568.6-2008

YS/T 656   GB/T 4325.5   GB/T 3458   YS/T 568.13   YS/T 568.12   YS/T 568.10   

Basic data

Standard ID YS/T 568.6-2008 (YS/T568.6-2008)
Description (Translated English) Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of titamium content. Diantipyrylmethane spectrophotometric method
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H63
Classification of International Standard 77.120.99
Word Count Estimation 6,629
Date of Issue 2008-03-12
Date of Implementation 2008-09-01
Older Standard (superseded by this standard) YS/T 568.6-2006
Regulation (derived from) NDRC Notice No. 25 of 2008
Issuing agency(ies) National Development and Reform Commission
Summary This standard specifies the zirconium oxide, hafnium determination of titanium content. This standard applies to zirconium oxide, hafnium oxide, titanium content. Measuring range: 0. 005% to 2. 5%.

YS/T 568.6-2008: Chemical analysis methods for zirconium oxide and hafnium oxide. Determination of titamium content. Diantipyrylmethane spectrophotometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods for zirconium oxide and hafnium oxide.Determination of titamium content.Diantipyrylmethane spectrophotometric method ICS 77.120.99 H63 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 568.6-2006 Zirconium oxide, hafnium oxide chemical analysis Determination of titanium content Two antipyrine DAM spectrophotometry Posted 2008-03-12 2008-09-01 implementation National Development and Reform Commission issued

Foreword

YS/T 568 "zirconium, hafnium oxide chemical analysis method" is divided into 11 parts. --- Part 1. Determination of zirconium and hafnium oxide combined amount of mandelic acid gravimetric method; --- Part 2. Determination of iron content sulfonic acid spectrophotometry; --- Part 3. Determination of the amount of silicon silicon molybdenum blue spectrophotometric method; --- Part 4. Determination of aluminum content of chromium azure S- cylpyridinium chloride spectrophotometry; --- Part 5. Determination of sodium content by flame atomic absorption spectrometry; --- Part 6. Determination of the amount of titanium di Zhao DAM spectrophotometry; --- Part 7. Determination of phosphorus content of antimony salt - ascorbic acid - phosphorus molybdenum blue spectrophotometric method; --- Part 8. zirconia aluminum, calcium, magnesium, manganese, sodium, nickel, iron, titanium, zinc, molybdenum, vanadium, hafnium content - Inductively coupled plasma fat Emission spectrometry; --- Part 9. hafnium oxide of aluminum, calcium, magnesium, manganese, sodium, nickel, iron, titanium, zinc, molybdenum, vanadium, zirconium content - Inductively coupled plasma fat Emission spectrometry; --- Part 10. Determination of manganese content - Potassium periodate spectrophotometric method; --- Part 11. Determination of α- linked furoylhydrazone nickel dioxime spectrophotometric method. Part is divided into 6 sections. The partial replacement of YS/T 568.6-2006 "zirconium oxide, hafnium titanium content determination" (formerly GB/T 2590.6-1981). This portion of YS/T 568.6-2006 compared to the main changes are as follows. --- Curve by the scope of 0 ~ 2.4μg/mL was adjusted to 0 ~ 3.0μg/mL; --- Added "7.1 repeatability" clause; --- Added "8 Quality assurance and control" clause. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This part by the Beijing Nonferrous Metal Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This part by the Guangzhou Research Institute of Nonferrous Metals, Beijing Nonferrous Metal Research Institute drafted. The main drafters of this section. Mai Libi, Dai Fengying, Zhang Jin, Liutian Ping, Wang Mulan. This part of the standard replaces the previous editions are. --- GB/T 2590.6-1981, YS/T 568.6-2006. Zirconium oxide, hafnium oxide chemical analysis Determination of titanium content Two antipyrine DAM spectrophotometry

1 Scope

This section specifies the determination method zirconium oxide, hafnium titanium content. This section applies to zirconium oxide, hafnium oxide - Determination of titanium content. Measurement range. 0.005% to 2.5%.

2 Method summary

Samples with sulfuric acid, ammonium sulfate is dissolved (or decomposition with hydrofluoric acid and nitric, hydrofluoric acid, sulfuric acid smoke rush), oxalic acid masking body zirconium, Hafnium, in order to eliminate the interference of ascorbic acid iron. In sulfuric acid medium, with two titanium antipyryl DAM forms a yellow complex wave spectrophotometer Measuring the absorbance at 430nm long.

3 Reagents

3.1 ammonium sulfate. 3.2 hydrochloride (ρ1.19g/mL). 3.3 sulfate (ρ1.84g/mL). 3.4 Hydrofluoric acid (ρ1.13g/mL). Nitrate 3.5 (ρ1.42g/mL). 3.6 two antipyrine DAM solution (50g/L). Weigh 20g two antipyrine DAM, placed in 500mL beaker, add salt 400mL Acid (1 + 24), heating and stirring until completely dissolved, cooled, filtered into a brown bottle. 3.7 oxalic acid solution (100g/L). 3.8 ascorbic acid solution (10g/L). the time is now equipped with. 3.9 sulfate (1 + 1). After Weigh 1.0000g titanium [(Ti) ≥99.9%], placed in 250mL platinum dish, add a little water. 3.10 Titanium standard stock solution Slowly dropping hydrofluoric acid (3.4) to dissolve, then dropping nitric acid (3.5) will be completely oxidized low-cost titanium added 10mL sulfuric acid (3.3), shake Evaporated on a hotplate until white smoke, remove, cool. Water moved into 1000mL volumetric flask, dilute to the mark with sulfuric acid (1 + 19). This solution 1mL containing 1.00mg titanium. 3.11 Titanium standard solution. Pipette 25mL titanium standard stock solution (3.10), placed in 250mL flask, add 15mL sulfuric acid (3.9), diluted with water to the mark. This solution 1mL containing 100μg titanium.

4 Instrument

Spectrophotometer. Step 5 Analysis 5.1 Sample Table 1 sample was weighed, accurate to 0.0001g. 5.2 Determination of the number of Independently measured twice and averaged.