HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YS/T 227.8-2010 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 227.8-2010: Methods for chemical analysis of bismuth. Part 8: Determination of magnesium and sodium content. Flame atomic absorption spectrometry

YS/T 227.8: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 227.8-2010English209 Add to Cart 3 days [Need to translate] Methods for chemical analysis of bismuth. Part 8: Determination of magnesium and sodium content. Flame atomic absorption spectrometry   YS/T 227.8-2010
YS/T 227.8-1994English199 Add to Cart 2 days [Need to translate] Determination of magnesium and sodium contents in tellurium. Atomic absorption spectrophotometric method Obsolete YS/T 227.8-1994

PDF similar to YS/T 227.8-2010


Standard similar to YS/T 227.8-2010

GB/T 3884.2   GB/T 3884.1   YS/T 252.1   YS/T 227.12   YS/T 227.1   YS/T 227.10   

Basic data

Standard ID YS/T 227.8-2010 (YS/T227.8-2010)
Description (Translated English) Methods for chemical analysis of bismuth. Part 8: Determination of magnesium and sodium content. Flame atomic absorption spectrometry
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H13
Classification of International Standard 77.120.99
Word Count Estimation 6,686
Date of Issue 2010-11-13
Date of Implementation 2011-03-01
Older Standard (superseded by this standard) YS/T 227.8-1994
Regulation (derived from) MIIT (2010) No. 126
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the amount of magnesium and sodium tellurium volume method. This standard applies to the amount of magnesium and sodium tellurium content. Measuring range: Mg: 0. 0005 ~ 0. 0030%, Na

YS/T 227.8-2010: Methods for chemical analysis of bismuth. Part 8: Determination of magnesium and sodium content. Flame atomic absorption spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of bismuth.Part 8. Determination of magnesium and sodium content.Flame atomic absorption spectrometry ICS 77.120.99 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 227.8-1994 Methods for chemical analysis of tellurium Part 8. magnesium, sodium content determination Flame Atomic Absorption Spectrometry Part 8. Determinationofmagnesiumandsodiumcontent- Issued on. 2010-11-13 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 227 "tellurium chemical analysis methods," a total of 12 parts. --- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry; --- Part 3. Determination of lead content by flame atomic absorption spectrometry; --- Part 4. Determination of iron content - Phenanthroline spectrophotometric method; --- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry; --- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry; --- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry; --- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry; --- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method; --- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method; --- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry. This section section 8. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of YS/T 227.8-1994 "tellurium magnesium, sodium content was measured (atomic absorption spectrometry)." And YS/T 227.8-1994 Compared to the main part of the following changes. --- Measurement range, Mg from 0.001% to 0.002% by the expansion of 0.0005% ~ 0.0030%, Na 0.006% from 0.003% Extended 0.0020% 0.0070%; --- Complements the precision, quality assurance and control provisions; --- Complements the "test report" requirement. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd. It participated in the drafting of this section. Jiangxi Copper Corporation, Sichuan Apollo Solar Energy Technology Co., Ltd. The main drafters of this section. Lei Su letter, Jiang Qing, a resumed Hu, Wang Xueping, Yan Ge. This part of the standard replaces the previous editions are. --- YS/T 227.8-1994; --- GB/T 2144-1980. Methods for chemical analysis of tellurium Part 8. magnesium, sodium content determination Flame Atomic Absorption Spectrometry Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

YS/T of the provisions of the section 227 determination of tellurium in the amount of magnesium and sodium content. This section applies to the determination of tellurium in the amount of magnesium and sodium content. Measuring range. Mg. 0.0005% ~ 0.0030%; Na. 0.0020% ~ 0.0070%.

2 principle of the method

Sample with nitric acid and hydrochloric acid dissolved, strontium salt eliminate the interference of coexisting elements in dilute nitric acid and hydrochloric acid medium, using air - acetylene fire Flame atomic absorption spectrometer wavelength 285.2nm, 589.0nm measured magnesium, sodium absorbance to a standard curve method to calculate the amount of magnesium, sodium content.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as an analytical reagent and water. Nitrate 3.1 (ρ1.40g/mL), ultra-pure. 3.2 hydrochloride (ρ1.19g/mL), ultra-pure. 3.3 nitric acid (11). 3.4 nitric acid (110). 3.5 hydrochloride (11). 3.6 Strontium nitrate solution (100g/L). 3.7 Magnesium standard stock solution. Weigh 0.1000g of magnesium (≥99.95%), placed in 100mL beaker, add 20mL of nitric acid (3.4), Was heated until complete dissolution, boiling rid of nitrogen oxides, is removed, cooled and transferred to 1000mL volumetric flask, dilute to the mark with water and mix. This solution 1mL containing 100μg magnesium. 3.8 Sodium standard stock solution. Weigh 0.2545g pre-drying at 120 ℃ reference reagent sodium chloride, placed 100mL beaker, add A small amount of water dissolved and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100μg sodium. 3.9 Magnesium standard solution. Pipette 10.00mL magnesium standard stock solution (3.7) in 200mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 5μg magnesium. 3.10 Sodium standard solution. Pipette 12.00mL sodium standard stock solution (3.8) in 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 12μg sodium.

4 Instrument

Atomic absorption spectrometer, with magnesium, sodium hollow cathode lamp.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 227.8-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 227.8-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 227.8-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 227.8-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 227.8-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 227.8-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.