HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

SN/T 4308-2015 English PDF

US$189.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 4308-2015: Determination of chromium, nickel, silicon, manganese, aluminium, phosphorus, tungsten, molybdenum, cobalt, vanadium content in alloy steel - Inductively coupled plasma atomic emission spectrometric method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 4308-2015English189 Add to Cart 3 days [Need to translate] Determination of chromium, nickel, silicon, manganese, aluminium, phosphorus, tungsten, molybdenum, cobalt, vanadium content in alloy steel - Inductively coupled plasma atomic emission spectrometric method Valid SN/T 4308-2015

PDF similar to SN/T 4308-2015


Standard similar to SN/T 4308-2015

GB/T 3654.3   GB/T 4336   GB/T 4701.1   SN/T 5570   SN/T 4757   SN/T 3789   

Basic data

Standard ID SN/T 4308-2015 (SN/T4308-2015)
Description (Translated English) Determination of chromium, nickel, silicon, manganese, aluminium, phosphorus, tungsten, molybdenum, cobalt, vanadium content in alloy steel - Inductively coupled plasma atomic emission spectrometric method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard H11
Word Count Estimation 8,828
Date of Issue 2015-09-02
Date of Implementation 2016-04-01
Quoted Standard GB/T 6682
Regulation (derived from) AQSIQ Announcement 2015 - Batch 3 - 103 Industry Standards
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the determination of chromium in steel, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, cobalt, vanadium content by inductively coupled plasma emission spectrometry method (ICP-OES). This standard applies to chromium, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, cobalt, vanadium content in steel was measured, the measurement range of each element in Table 1.

SN/T 4308-2015: Determination of chromium, nickel, silicon, manganese, aluminium, phosphorus, tungsten, molybdenum, cobalt, vanadium content in alloy steel - Inductively coupled plasma atomic emission spectrometric method



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Determination of chromium alloy steels, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, cobalt, vanadium content of ICP-OES method) People's Republic of China Entry-Exit Inspection and Quarantine Standards Alloy Steel chromium, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, Cobalt, vanadium content - ICP-OES method Determinationofchromium, nickel, silicon, manganese, aluminium, phosphorus, tungsten, molybdenum, cobalt, vanadiumcontentinaloysteel- Issued on. 2015-09-02 2016-04-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. Jilin People's Republic of China Exit Inspection and Quarantine. The main drafters of this standard. Xie Ping, Yang Lu, Xu Liming, Xu Zhibin, Zhang Xuguang. Alloy Steel chromium, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, Cobalt, vanadium content - ICP-OES method

1 Scope

Alloy steel in this standard refers to stainless steel, high alloy steel and heat-resistant alloy. This standard specifies the determination of chromium in steel, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, cobalt, vanadium content by inductively coupled plasma atomic emission spectrometry Analysis (ICP-OES). This standard applies to chromium, nickel, silicon, manganese, aluminum, phosphorus, tungsten, molybdenum, cobalt, vanadium content in steel was measured, the measurement range of each element in Table 1. Table 1 measurement range of each element Element measurement range (mass fraction) /% Chromium 0.01 to 22.00 Nickel 0.01 to 23.00 Silicon 0.02 to 5.00 Manganese 0.01 to 13.60 Aluminum 0.01 to 2.00 P 0.01 to 0.20 Tungsten 0.01 to 1.00 Molybdenum 0.01 to 5.00 Cobalt 0.01 to 1.00 Vanadium 0.01 to 3.00

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Laboratory use specifications and test methods GB/T 6682 Analysis

3 Method summary

After the specimen is dissolved in aqua regia and diluted to determine the volume of the sample solution is injected into the plasma flame, and this light source, plasma Body element corresponding wavelength spectrometer, measure the light intensity to determine its content from the standard curve.

4 Reagents and materials

Unless otherwise indicated in the analysis using only recognized as analytical reagents and GB/T 6682 provisions of secondary water.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 4308-2015_English be delivered?

Answer: Upon your order, we will start to translate SN/T 4308-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 4308-2015_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 4308-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.