Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 1843.2-2013English399 Add to Cart 3 days [Need to translate] Rules for the inspection of electrical equipment for measurement, control, and laboratory use for import and export. Part 2: Alternating current static watt-hour meters Obsolete SN/T 1843.2-2013
SN/T 1843.2-2006English399 Add to Cart 3 days [Need to translate] Import and export instrumentation testing procedures - Part 2: Static AC power meter Obsolete SN/T 1843.2-2006

PDF similar to SN/T 1843.2-2013


Standard similar to SN/T 1843.2-2013

GB/T 15284   GB/T 17215.321   GB/T 31983.11   SN/T 1843.4   SN/T 1843.3   

Basic data

Standard ID SN/T 1843.2-2013 (SN/T1843.2-2013)
Description (Translated English) Rules for the inspection of electrical equipment for measurement, control, and laboratory use for import and export. Part 2: Alternating current static watt-hour meters
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard N22
Classification of International Standard 17.220.20
Word Count Estimation 10,175
Older Standard (superseded by this standard) SN/T 1843.2-2006
Quoted Standard GB/T 2828.1; GB/T 17215.211-2006; GB/T 17215.321-2008; GB/T 17215.322-2008; GB/T 17215.323-2008
Regulation (derived from) National quality recognition (2013) 569
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the sampling and export static AC power meter to determine test methods and test results. This standard applies to one or more measurement devices and counters and packed in the same case which consists of indoor and outdoor use st

SN/T 1843.2-2013: Rules for the inspection of electrical equipment for measurement, control, and laboratory use for import and export. Part 2: Alternating current static watt-hour meters


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules for the inspection of electrical equipment for measurement, control, and laboratory use for import and export Part 2. Alternating current static watt-hour meters People's Republic of China Entry-Exit Inspection and Quarantine Standards Instead of the SN/T 1843.2-2006 Importers measurement, control and laboratory use electrical equipment Test procedures - Part 2. Static AC power meter measurement, control, andlaboratoryuseforimportandexport- Part 2. Alternatingcurrentstaticwatt-hourmeters Issued on. 2013-11-06 2014-06-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

SN/T 1843 "Importers measurement, control and laboratory testing procedures for electrical equipment" is divided into three parts. --- Part 1. General requirements; --- Part 2. Static AC power meter; --- Part 3. Analog/digital multimeter. This section SN/T 1843 Part 2. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of SN/T 1843.2-2006 "Importers measurement, control and laboratory inspection of electrical equipment - Part 2. Static Only AC power meter ", compared with the SN/T 1843.2-2006, the main changes are as follows. --- National standards in Chapter 2, "normative references" new release (GB/T 17215.211-2006/IEC 62052-11.2003, GB/T 17215.321-2008/IEC 62053-21.2003, GB/T 17215.322-2008/IEC 62053-22.2003, GB/T 17215.323-2008/IEC 62053-23.2003) Replace the old national standard (GB/T 17215-2002, GB/T 17882-1999, GB/T 17883-1999). --- "5.5 Sampling Inspection. Sampling" in the Health Check program to check the level of a sample has been adjusted, and increased acceptance quality limit (AQL value). --- "5.5 Sampling Inspection. Inspection content" requirements and test methods, according to newly released national standards will be adjusted accordingly, Increase substandard classification. --- "5.5 sampling. results found" in the adjusted by acceptance quality limit (AQL value) is determined. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section drafted by. People's Republic of China Zhejiang Exit Inspection and Quarantine. The main drafters of this section. Xu Yongli, Lu Yang, WeiWeired package, on behalf of help. This part of the standard replaces the previous editions are. --- SN/T 1843.2-2006.

Introduction

This part is the import and export static AC power meter inspection work in accordance with the import and export static AC power meter test and play a guiding Normative role. With China's accession to the World Trade Organization (WTO) and the "People's Republic of China Import and Export Commodity Inspection Law" and its implementing regulations amendments, out Export Commodity Inspection work has changed greatly. To adapt to the situation and changes in the national inspection and quarantine department in charge of inspection and quarantine organizations have established standard Registration system. This part belongs to the standard system of inspection and quarantine fourth floor --- personality standard that specifies the requirements for import and export inspection static AC power meter. Importers measurement, control and laboratory use electrical equipment Test procedures - Part 2. Static AC power meter

1 Scope

SN/T 1843 provisions of this part of the sampling and export static AC power meter, the determination of test methods and test results. This section applies to both indoor and outdoor by one or more measuring elements and counters and packed in the same case which consists of using static cross Import and Export Inspection flow meter. Scope of this section. --- Level 1 and 2 static AC active energy meter; --- 0.2S and 0.5S grade level static AC active energy meter (only for indoor use); --- Level 2 Level 3 static AC reactive power meter.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2828.1 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch inspection sampling plan GB/T 17215.211-2006 AC measuring equipment General requirements, tests and test conditions Part 11. measuring equipment GB/T 17215.321-2008 AC measuring equipment - Specific requirements - Part 21. Static meters for active energy (level 1 and level 2) GB/T 17215.322-2008 AC measuring equipment - Specific requirements Part 22. Static meters for active energy (0.2S level and Class 0.5S) GB/T 17215.323-2008 AC measuring equipment - Specific requirements - Part 23. Static reactive energy (classes 2 and 3)

3 Terms and Definitions

GB/T 2828.1, GB/T 17215.211-2006, GB/T 17215.321-2008, GB/T 17215.322-2008, GB/T 17215.323-2008 defined and the following terms and definitions apply to this document. 3.1 Type Test mode modeoftypetest According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system. 3.2 Compliance Verification mode modeofcomplianceverification According to the mandatory requirements of national technical specifications, inspection certificate and inspection documents, goods are consistent with the random testing can be carried out when necessary, and real Shi conformity assessment activities supervision. 3.3 Sampling mode modeofsamplinginspection According to the mandatory requirements of national technical specifications, batch import and export commodities or pumping grant implementation sampling, testing and inspection of conformity assessment activities.