HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

QB/T 4096.1-2024 English PDF

US$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
QB/T 4096.1-2024: (Performance of room heaters for household and similar purposes - Part 1: General requirements)
Status: Valid

QB/T 4096.1: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
QB/T 4096.1-2024English439 Add to Cart 4 days [Need to translate] (Performance of room heaters for household and similar purposes - Part 1: General requirements) Valid QB/T 4096.1-2024
QB/T 4096-2010English150 Add to Cart 0--9 seconds. Auto-delivery Performance of Room Heater for Household and Similar Purposes - Part 1: General Requirements Obsolete QB/T 4096-2010

Basic data

Standard ID QB/T 4096.1-2024 (QB/T4096.1-2024)
Description (Translated English) (Performance of room heaters for household and similar purposes - Part 1: General requirements)
Sector / Industry Light Industry Standard (Recommended)
Classification of Chinese Standard Y63
Classification of International Standard 97.100.10
Word Count Estimation 21,229
Date of Issue 2024-03-29
Date of Implementation 2024-10-01
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the requirements for appearance, corrosion resistance, safety, electromagnetic compatibility, length of power cord, low temperature and low voltage start-up, heating effect, effective power, heating time, cooling, anti-freezing temperature, impact current, noise power level, durability, safe service life, standby power, humidification capacity, and mechanical properties of casters related to the performance of indoor heaters for household and similar purposes. It describes the corresponding test conditions and test methods, stipulates the inspection rules, marking, packaging, transportation and storage content, and gives product classifications that are convenient for technical regulations. This standard applies to the production, testing and sales of heaters with a rated voltage of no more than 250V for single-phase appliances and a rated voltage of no more than 480V for other appliances. This standard does not apply to: heaters installed in building structures.
QB/T 4096-2010 QB NATIONAL LIGHT INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 97.100.10 Classification No.. Y 63 Record No.. 30259-2011 Performance of Room Heater for Household and Similar Purposes - Part 1. General Requirements ISSUED ON. NOVEMBER 22, 2010 IMPLEMENTED ON. MARCH 01, 2011 Issued by. Ministry of Industry and Information Technology of PRC 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes.

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Terms and Definitions ... 5 4 Product Classification ... 5 5 Requirements ... 7 6 Test Methods ... 9 7 Inspection Rules ... 17 8 Mark, Package, Transportation, Storage ... 21 Appendix A (Informative) Naming Method of Product Model ... 23 Appendix B (Normative) Climate Laboratory ... 25

Foreword

The serial standard of QB/T 4096 Performance of Room Heater for Household and Similar Purposes can be divided into the following parts. --- Part 1. General Requirements; --- Part 2. Particular Requirements. This Part belongs to Part 1 of QB/T 4093. This Part’s Appendix is informative; while Appendix B is normative. This Part was proposed by China Light Industry Council. This Standard shall be under the jurisdiction of National Technical Committee for Standardization of Household Appliances. Drafting organizations of this Part. China Singfun Electric Group Co., Ltd., Ningbo Research Institute of Product Quality Supervision and Inspection, Midea Group Co., Ltd., Zhuhai Gree Electric Appliances Co., Ltd., China Electrical Apparatus Research Institute, Guangzhou Vkan Certification & Testing Institute, China Household Electric Appliance Research Institute, Baoerma Electric Appliance Group Co., Ltd., Cixi City Huier Electric Appliance Co., Ltd., Zhejiang Xinlianxin Electrical Appliance Co., Ltd., and Ningbo Sunny Electrical Heating Appliances Co., Ltd. Chief drafting staffs of this Part. Fang Qinglian, Bao Jun, Chi Xuejun, Liao Wangbin, Li Bingcheng, Li Yi, Song Wenhui, Wang Rongqi, Xu Yanda, Zhang Guoqing, and Zhu Yongguo. This Part was first-time published. Performance of Room Heater for Household and Similar Purposes - Part 1. General Requirements

Scope

This Part specifies the scope, terms and definitions, product classification, requirements, test methods, inspection rules, and mark, package, transportation, storage of room heater for household and similar purposes (hereinafter referred to as “heater”). This Part is applicable to the heater of which the single-phase rated voltage is not greater than 250V; and other appliances of which the rated voltage is not greater than 480V. They can be portable, fixed, standing or embedded heaters. This Part is not applicable to. --- Heater installed in the building structure; --- Central heating system; --- Heater connecting with air duct; --- Wallpaper, blanket, curtain or pipe equipped with soft electric heating elements; --- Thermal-storage room heater for household; --- Heater in bathroom (bath heater).

Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods GB/T 1019-2008 General Requirements for the Package of Household and Similar Electrical Appliances GB/T 2421-1999 Environmental Testing for Electric and Electronic Products - Part 1. General and Guidance GB/T 2423.17-1993 Basic Environmental Testing Procedures for Electric and Electronic Products Test Ka. Salt Mist GB/T 2828.1-2003 Sampling Procedures for Inspection by Attribute - Part 1. Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-Lot Inspection GB/T 2829-2002 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB/T 4214.1-2000 Acoustics - Household and Similar Electrical Appliances - Test Code for Determination of Airborne Acoustical Noise - Part 1. General Requirements GB 4706.1 Household and Similar Electrical Appliance - Safety - Part 1. General Requirements GB 4706.23 Safety of Household and Similar Electrical Appliances - Particular Requirements for Room Heater GB 5296.2 Instructions for Use of Consumer Interest - Instructions for Use of Household and Similar Electrical Appliances GB/T 15470-2002 Household Electric Direct-Acting Room Heaters - Methods for Measuring Performance GB/T 21097.1-2007 General Requirements on Fixed Number of Years of Safety Use and Recycling for Household and Similar Electrical Appliances QB/T 3901-1999 The General Rule of Naming Model of Household Electrical Appliances

Terms and Definitions

In addition to the terms and definitions stipulated in GB 4706.1, GB 4706.23 and GB/T 15470-2002, this Part also adopts the following terms and definitions. 3.1 Multiunit heater The composite appliance with at least 2 kinds of heating functions to heat the room. 4 Product Classification 4.1 Classification as per types 5.2 Appearance 5.2.1 The surface of electroplate part shall be fine, uniformly-colored, and exempted from the following defects such as spots, peeling, threadbare, pinhole, bubbling, obvious flaws and scratches, etc. After the corrosion resistance test, its surface, edges and corners shall appear no rust point with diameter of 2mm above. 5.2.2 The surface of paint-coated (plastic-coated) parts shall be flat, light, uniformly- colored, firm paining layer, strong adhesion; its main surface shall be exempted from the following defects that affect the appearance such as flow-paint (flow-plastic), scars, orange peels, primer exposed, cracks, peeling, etc. 5.2.3 The surface of plastic part shall be smooth, uniformly-colored, and exempt from the obvious scars, scratches, or depression. 5.2.4 The nameplate and decorative plate of the heater shall be durable; after the durability test, it shall be exempted from deformation, peeling; and its pattern and writing are legible. 5.3 Length of power cord For the heater with plug power cord, its power cord length shall be no less than 1.3m. 5.4 Start-up For the heater with motor, under the 0.85 times of rated voltage, the motor can be started-up normally. 5.5 Heating effect 5.5.1 The specific limits of the heating effect shall meet the special requirements of the corresponding types of heater. 5.5.2 For the convection heater and fan heater, their heating effect shall be inspected according to the temperature rise on the surrounding surface. NOTE. the temperature rise on the surrounding surface indicates the temperature rise of the measuring points around the heater. 5.5.3 For the plate heater, radiant heater and visible glowing radiant heater, their heating effect shall be inspected according to the radiant temperature rise. 5.5.4 For the multiunit heater, its heating effect shall be inspected as per the heating type by the temperature rise on surrounding surface and radiant temperature rise. NOTE. the temperature rise on the surrounding surface indicates the temperature rise of the measuring points around the heater. Place the 1.5m-wide, 1.0m-high, 20mm-thick plywood coated berlin black on the position where it forms right angle with the radiation direction of the heater; and at a distance of 1m from the most protruding point at the furthest end on the external surface of the heater radiation direction. The plywood center shall coincide with the projection center of the heater radiation surface on the plywood. As shown in Figure 4, separately arrange the 5 thermocouples on the center and at the furthest end on the long and short shaft of the radiation projection surface. Figure 5 is the radiation temperature-rise test schematic diagram. Energize the heater; meanwhile use the temperature measurement and record instrument to record the heating curve from the room temperature to the steady-state temperature, which is shown in Figure 3. Record the measured temperature when the steady-state is established. When the steady-state is established, measure the temperature. Single-point temperature-rise can be calculated by the difference between steady-state temperature of the thermocouple on the plywood and the thermocouple initial temperature. The above-mentioned 5-point temperature arithmetic mean is the radiation temperature-rise, which shall be rounded to the nearest ...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of QB/T 4096.1-2024_English be delivered?

Answer: Upon your order, we will start to translate QB/T 4096.1-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of QB/T 4096.1-2024_English with my colleagues?

Answer: Yes. The purchased PDF of QB/T 4096.1-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version QB/T 4096.1-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version QB/T 4096.1-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.