US$559.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 506-2010: Verification regulation of D.C.current comparator bridge Status: Valid JJG 506: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 506-2010 | English | 559 |
Add to Cart
|
5 days [Need to translate]
|
Verification regulation of D.C.current comparator bridge
| Valid |
JJG 506-2010
|
JJG 506-1987 | English | 679 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of DC Comparator Bridge
| Obsolete |
JJG 506-1987
|
PDF similar to JJG 506-2010
Basic data Standard ID | JJG 506-2010 (JJG506-2010) | Description (Translated English) | Verification regulation of D.C.current comparator bridge | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 24,265 | Date of Issue | 2010-05-11 | Date of Implementation | 2010-11-11 | Older Standard (superseded by this standard) | JJG 506-1987 | Quoted Standard | JJG 166-1993; JJG 2051-1990; GB/T 3930-2008; JJF 1002-1998; JJF 1059-1999 | Regulation (derived from) | AQSIQ Announcement No. 50 of 2010 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to DC current comparator primary and secondary magnetic potential balance and the primary and secondary resistance on two potential equilibrium conditions, the measured resistance or resistance ratio bridge, that bridge DC compare ceremony (hereinafter referred to compare electricity ceremony bridge or bridge) of the initial verification, testing and use of follow-up inspection, also applies to multi-function electrical DC comparator bridge part. This procedure does not apply to DC compare ceremony bridge and automatic temperature compared ceremony bridge DC test. |
JJG 506-2010: Verification regulation of D.C.current comparator bridge---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of DCcurrent comparator bridge
State verification procedures People's Republic of China
DC Comparator Bridge
Issued on. 2010-05-11
2010-11-11 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
DC Comparator Bridge test procedures
Replacing JJG 506-1987
The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on May 11, 2010, and from
From November 11, 2010 into effect.
Focal point. the National Technical Committee on Electromagnetic measurement
Main drafting unit. Heilongjiang Provincial Academy of verification test
China Institute of Metrology
Participated in the drafting. the Highland Sting Instrument Research Institute
Dalian metrological verification tests
The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic
The main drafters of this procedure.
Wang Yong (Heilongjiang Provincial Academy of verification test)
Shao Haiming (China Institute of Metrology)
Chang Group (Heilongjiang Provincial Academy of verification test)
Drafters participate.
Zhu Qing hair (on Highland Sting Instrument Research Institute)
Han Jing (Dalian metrological verification tests)
Cui Lijuan (Dalian metrological verification tests)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Overview (1)
4 metering performance requirements (2)
4.1 accuracy class (2)
4.2 basic error (2)
4.3 Non-linear error (3)
4.4 magnetic potential low frequency noise (3)
4.5 magnetic potential zero drift (3)
4.6 Included galvanometer indicator (4)
5 General technical requirements (4)
5.1 appearance of the structure (4)
5.2 Insulation resistance (4)
5.3 Dielectric strength (4)
6 Control of measuring instruments (4)
6.1 Verification condition (4)
6.2 Verification Project (4)
6.3 Verification Methods (6)
6.4 overall verification (11)
6.5 Verification Results processing (11)
6.6 test cycle (11)
Appendix A linearity self-test form (13)
Appendix B linearity self-test derived formula (16)
Appendix C test certificate page format (18)
Appendix D test results in the notice page format (19)
DC Comparator Bridge test procedures
1 Scope
The order applies to the beginning of the DC current comparator, the potential of the secondary magnetic potential balance and the primary and secondary resistance balancing two strips
Under parts, measuring resistance or resistance ratio bridge that DC Comparator Bridge (hereinafter referred to as Comparator Bridge or electricity
Bridge) initial verification, subsequent verification and in-service inspection; also applies to the bridge portion of the multi-purpose comparator DC.
This procedure does not apply to DC Comparator Bridge and automatic temperature calibration of DC Comparator Bridge.
2 Citations
JJG 166-1993 DC resistance test procedures
JJG 2051-1990 DC Resistance Measuring Instruments Systems
GB/T 3930-2008 resistance measurement with DC bridge
JJF1002-1998 national verification procedures to write rules
JJF1059-1999 Evaluation and Expression of Uncertainty in Measurement
When using this procedure, it should pay attention to using the currently valid version of the documents cited.
3 Overview
Comparator Bridge is in DC Current Comparator magnetic potential balance by adjusting the comparator primary or secondary turns,
To accurately adjust the current measured resistance ratio between the primary and secondary standard resistor, the two resistor voltage reaches equilibrium, the electric
Drag ratio equals the turns ratio, and so relatively high precision resistance measurement instruments.
Comparator Bridge and normal DC resistance bridge, are relatively instrument measuring resistance, but the role of the principle of
Different, the difference is. Comparator Bridge to compensate for the measurement of the bridge instead of the latter measurement, thoroughly overcome
The potential impact of lead resistance and contact resistance of the side button, and facilitates comparison of different nominal resistance measurements (over
Ferry transfer); magnetic potential balance with the former premise, instead of the latter with a turns ratio of the resistance ratio, resulting in higher quasi
Accuracy. Comparator Bridge circuit principle shown in Figure 1 works as follows.
a. magnetic potential balance
The primary winding and the secondary measured variable has a respective stator windings trimming DC current, which is generated in the iron core
The opposite direction of the magnetic potential, the potential difference detected by the magnetic detection coil, and the closed-loop tracking and have poor conditioning system by manual adjustment
Automatically adjust the slave (servo) Power generated by the secondary current, the magnetic potential balance that IxWx = IsWs, so there
Is
Ix =
Wx
Ws
b. Potential equalization
Adjusted measuring disk or the secondary winding trim (deviation disk) that regulate Is/Ix, so that means zero galvanometer G, the Rx and
The Rs voltage drop equal, IxRx = IsRs, then. IsIx =
Rx
Rs
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 506-2010_English be delivered?Answer: Upon your order, we will start to translate JJG 506-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 506-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJG 506-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 506-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 506-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|