US$579.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 441-2008: Verification Regulation of Alternating Current Bridge Status: Valid JJG 441: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 441-2008 | English | 579 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of Alternating Current Bridge
| Valid |
JJG 441-2008
|
JJG 441-1986 | English | 759 |
Add to Cart
|
5 days [Need to translate]
|
Alternating Current Bridge
| Obsolete |
JJG 441-1986
|
PDF similar to JJG 441-2008
Basic data Standard ID | JJG 441-2008 (JJG441-2008) | Description (Translated English) | Verification Regulation of Alternating Current Bridge | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A55 | Classification of International Standard | 17.220 | Word Count Estimation | 25,253 | Date of Issue | 2008-04-28 | Date of Implementation | 2008-10-23 | Older Standard (superseded by this standard) | JJG 441-1986 | Quoted Standard | JJF 1001-1998; JJG 2073-1990; JJG 2075-1990; JJG 2076-1990; JJG 183-1992; JJG 726-1991; IEC 477.2-1979 | Regulation (derived from) | ?AQSIQ Announcement 2008 No.45 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to initial verification AC bridge, follow-up test and use the test. AC bridge operating frequency is limited to within the range of 20Hz to 100kHz, the working voltage is less than 500V, accuracy range of 0. 001 and below. This procedure does not apply to high-voltage bridge, verification LCR impedance meter and automatic balancing of the bridge. |
JJG 441-2008: Verification Regulation of Alternating Current Bridge---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Alternating Current Bridge
State verification procedures People's Republic of China
Alternating current bridge
Posted 2008-04-23
2008-10-23 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
AC Bridge Verification Regulation
Replacing JJG 441-1986
The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on April 23, 2008, and from
From October 23, 2008 into effect.
Focal point. the National Technical Committee on Electromagnetic measurement
Drafting units. China Institute of Metrology
The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic
The main drafters of this procedure.
Wang Chao (China Institute of Metrology)
Ruanyong Shun (China Institute of Metrology)
Drafters participate.
Lu Qing (China Institute of Metrology)
table of Contents
1 Scope (1)
2. Referenced Documents (1)
3 Overview (1)
4 Terminology (1)
5 metering performance requirements (2)
5.1 AC bridge primary and secondary parameter parameters of basic error (2)
5.2 accuracy class AC bridge (2)
5.3 Sensitivity (2)
5.4 Insulation Resistance (2)
5.5 dielectric strength (2)
5.6 Effect of the amount of the reference conditions and allow variation (3)
6 General Requirements (3)
6.1 Appearance and line (3)
Labeled 6.2 (3)
6.3 shield and connection (3)
6.4 Technical Paper (3)
7 control of measuring instruments (3)
7.1 test conditions (3)
7.2 test equipment (4)
7.3 test items and test methods (5)
7.4 Verification Results processing (11)
7.5 test cycle (11)
Appendix A combined loss factor and the quality factor of the standard device Standard (12)
Appendix B AC Bridge Some typical examples of specific verification step (14)
Appendix C original record format (16)
Appendix D Schedule (18)
Appendix E test certificate-page format (19)
AC Bridge Verification Regulation
1 Scope
The initial verification procedure for an alternating current bridge, verification and subsequent use of the test. Working frequency alternating current bridge
Rate limited within the range 20Hz to 100kHz, working voltage is less than 500V; accuracy and range of 0.001 or less.
This procedure does not apply to high-voltage bridge, LCR impedance meter verification and automatic balancing bridge.
2 Citations
JJF1001-1998 "common measurement terms and definitions"
JJG 2073-1990 "loss factor measuring instruments verification system."
JJG 2075-1990 "capacitance measuring instruments verification system"
JJG 2076-1990 "inductance Measuring Instruments Systems"
JJG 183-1992 "standard capacitor test procedures"
JJG 726-1991 "standard inductor test procedures"
IEC 477-2-1979 "Laboratory ac resistors"
When using this procedure should be noted that the above citations of current valid version.
3 Overview
AC bridge is a schematic comparison with the difference between the two AC impedance measurements, measuring impedance element main parameters and Deputy Senate
It means the amount. AC bridge by the ratio, standard, a sine wave power indicator (null indicator), and adjusting means
The measured impedance element.
According to the principle of balance, and so on can be divided into current, voltage, etc., and so the power bridge. According to the measured object (purpose), it can be divided into
Capacitance bridge, resistance bridge, bridge and multimeter inductance bridge. Press balanced manner, it can be divided into complete and incomplete equilibrium level
Heng types of bridge.
4 Terminology
Main parameters majorparameter
AC impedance element "inductor", "capacitor" and "resistor" in L, C and R values.
Deputy parameter sacontparameter
AC impedance element "inductor", "capacitor" and "resistance" on the quadrature component Q, D and τ values.
The basic measuring range intrinsicmeasuringrange
Within the bridge measurement range, allowing the smallest error measurement range.
Extended measuring range expandedmeasuringrange
Within the bridge measurement range, remove the measurement range other than the basic measurement range.
Basic error intrinsicerror (IEC 311-03-08)
Bridge at reference conditions, the basic measurement error in the range shown.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 441-2008_English be delivered?Answer: Upon your order, we will start to translate JJG 441-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 441-2008_English with my colleagues?Answer: Yes. The purchased PDF of JJG 441-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 441-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 441-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|