JJF 1846-2020: Calibration Specification for Chute Weighing Instruments
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1846-2020English369 Add to Cart 4 days [Need to translate] Calibration Specification for Chute Weighing Instruments Valid JJF 1846-2020

PDF similar to JJF 1846-2020


Standard similar to JJF 1846-2020

JJF 1943   GB/T 36126   GB/T 1885   JJF 1840   JJF 1842   JJF 1839   

Basic data

Standard ID JJF 1846-2020 (JJF1846-2020)
Description (Translated English) Calibration Specification for Chute Weighing Instruments
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 16,158
Date of Issue 2020-07-02
Date of Implementation 2021-01-02
Quoted Standard JJF 1181; GB/T 35593
Regulation (derived from) Announcement No. 29 (2020) of the State Administration for Market Regulation
Issuing agency(ies) State Administration for Market Regulation
Summary This standard applies to the calibration of chute scales that use the principle of gravity and/or impulse to determine and accumulate the mass of bulk materials in a continuous weighing method. This standard does not apply to the calibration of chute scales whose measuring element is a differential pressure transmitter.

JJF 1846-2020: Calibration Specification for Chute Weighing Instruments

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration Specification for Chute Scale) National Metrology Technical Specifications of the People's Republic of China Calibration Specification for Chute Scale 2020-07-02 released 2021-01-02 implementation Issued by the State Administration for Market Regulation Calibration Specification for Chute Scale Focal point. National Weighing Instrument Metrology Technical Committee Automatic Weighing Instrument Sub-Technical Committee Main drafting unit. Shanxi Institute of Metrology National Railway Weighing Station Participating in the drafting unit. Jiangsu Institute of Metrology National Coal Mine Safety Measuring Instruments Product Quality Supervision and Inspection Center Shanxi Xinyuan Automation Instrument Co., Ltd. China Railway Xi'an Bureau Group Co., Ltd. Institute of Science and Technology This specification entrusts the National Weighing Instrument Metrology Technical Committee Automatic Weighing Instrument Sub-Technical Committee to be responsible for interpretation The main drafters of this specification. Gao Ping (Shanxi Institute of Metrology) Yuan Fang (Shanxi Institute of Metrology) An Aimin (National Railway Scale Measuring Station) Participating drafters. Ma Xiaobing (Jiangsu Institute of Metrology) Kang Junpeng (National Coal Mine Safety Measuring Instruments Product Quality Supervision and Inspection Center) Liang Yuewu (Shanxi Xinyuan Automation Instrument Co., Ltd.) Zhang Yudong (Institute of Science and Technology, China Railway Xi'an Bureau Group Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Terms and measurement units (1) 3.1 Term (1) 3.2 Unit of measurement (2) 4 Overview (2) 5 Measurement characteristics (2) 5.1 Indication error of material test (2) 5.2 Material test repeatability (3) 6 Calibration conditions (3) 6.1 Environmental conditions (3) 6.2 Measurement standards and other equipment (3) 7 Calibration items and calibration methods (3) 7.1 Calibration items (3) 7.2 Calibration method (4) 8 Calibration result expression (6) 9 Recalibration interval (6) Appendix A Recommended Format of Calibration Original Record (7) Appendix B Recommended Format of the Internal Page of the Calibration Certificate (8) Appendix C Example of Uncertainty Evaluation of Indication Error of Material Test (9)

Introduction

JJF 1001-2011 "General Metrology Terms and Definitions", JJF 1059.1-2012 "Measuring Uncertainty Evaluation and Representation” and JJF 1071-2010 “Rules for the Compilation of National Metrology and Calibration Specifications” together constitute the support for the formulation of this specification The basic series of specifications. This specification is released for the first time. Calibration Specification for Chute Scale

1 Scope

This specification applies to the use of gravity and/or impulse principles to determine and accumulate bulk materials in a continuous weighing method Calibration of quality chute scales. This specification does not apply to the calibration of chute scales whose measuring element is a differential pressure transmitter.

2 Reference documents

This specification refers to the following documents. JJF 1181 Weighing instrument measurement terms and definitions GB/T 35593 Chute scale For dated reference documents, only the dated version applies to this specification; for undated reference documents, The latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

3.1 Term The following terms and definitions defined by JJF 1181 and GB/T 35593 apply to this code. 3.1.1 Chute scale An automatic weighing instrument that continuously weighs the bulk materials sliding through the chute without subdividing the quality category. 3.1.2 Maximum flow The flow rate derived from the maximum carrying capacity of the gravity measuring unit and the impulse measuring unit of the chute scale is Qmax. 3.1.3 Minimum flow The lower limit of flow measurement that can ensure compliance with the specified relative error requirements, the symbol is Qmin. 3.1.4 Feeding flow The flow of material from the previous device to the guide chute. 3.1.5 Cumulative division value In the normal weighing mode of the chute scale, the total cumulative display or partial cumulative display shows the difference between two adjacent values in mass units, and the symbol is dt. 3.1.6 Minimum cumulative load The quantity expressed in mass units can guarantee the minimum cumulative value of the chute scale that meets the specified relative error requirements. The symbol is ∑ min. 3.1.7 Gravity measurement unit A device that provides information on the weight of the measured load on the chute scale. The gravity measurement unit consists of a gravity chute and a gravity measurement sensor.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1846-2020_English be delivered?

Answer: Upon your order, we will start to translate JJF 1846-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1846-2020_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1846-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.