US$1369.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1789-2019: Program of Pattern Evaluation of Pressure Transmitters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1789-2019 | English | 1369 |
Add to Cart
|
7 days [Need to translate]
|
Program of Pattern Evaluation of Pressure Transmitters
| Valid |
JJF 1789-2019
|
PDF similar to JJF 1789-2019
Basic data Standard ID | JJF 1789-2019 (JJF1789-2019) | Description (Translated English) | Program of Pattern Evaluation of Pressure Transmitters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.100 | Word Count Estimation | 64,654 | Date of Issue | 2019 | Date of Implementation | 2020-03-31 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1789-2019: Program of Pattern Evaluation of Pressure Transmitters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Type evaluation outline of pressure transmitter)
National Measurement Technical Specification of the People's Republic of China
Type evaluation outline of pressure transmitter
Published on December 31,.2019
2020-03-31 Implementation
Issued by the State Administration of Market Supervision and Administration
Type evaluation outline of pressure transmitter
Centralized unit. National Pressure Measurement Technical Committee
Main drafting unit. Shanghai Institute of Metrology and Testing Technology
Participated in the drafting unit. Shanghai Haoge Measurement Technology Group Co., Ltd.
This specification entrusts the National Pressure Measurement Technical Committee to interpret
The main drafters of this specification.
Tu Limeng (Shanghai Institute of Metrology and Testing Technology)
Juan Lun
Wang Can (Shanghai Institute of Metrology and Testing Technology)
Participating drafters.
Feng Qibin (Shanghai Institute of Metrology and Testing Technology)
Wu Hao (Shanghai Hauge Measurement Technology Group Co., Ltd.)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2 References (1)
3 Terms and definitions (1)
3.1 Consistency (1)
3.2 Independent consistency (1)
3.3 End-group consistency (1)
3.4 Zero-base consistency (1)
3.5 Residual change (2)
3.6 Step response time (2)
3.7 Dead zone (2)
4 Overview (2)
5 Legal management requirements (2)
5.1 Unit of measurement (2)
5.2 Accuracy class (2)
5.3 Marks and logos (2)
5.4 External structure design requirements (3)
5.5 Provide technical documents and test prototypes for review (3)
6 Measurement requirements (3)
6.1 Indication error (3)
6.2 Return difference (3)
6.3 Repeatability (3)
6.4 End-group consistency (3)
6.5 Dead zone (3)
7 General technical requirements (4)
7.1 Normal working conditions (4)
7.2 Reference working conditions (4)
7.3 Functional characteristics (5)
7.4 Appearance (5)
7.5 Starting drift (5)
7.6 Long-term drift (5)
7.7 Frequency response (5)
7.8 Step response (5)
7.9 Items related to impact (6)
7.10 Items related to power input and electrical signal output (8)
8 Type Evaluation Project Table (13)
9 Test conditions and methods (15)
9.1 Test conditions (15)
9.2 Test equipment (15)
9.3 Test points (16)
9.4 Indication error (16)
9.5 Return difference (17)
9.6 Repeatability (17)
9.7 End-group consistency (18)
9.8 Dead Zone (18)
9.9 Items related to functional characteristics (19)
9.10 Appearance (21)
9.11 Starting drift (21)
9.12 Long-term drift (21)
9.13 Frequency response (22)
9.14 Step response (22)
9.15 Items related to impact (23)
9.16 Items related to power input and electrical signal output (30)
10 Judgment principles of type evaluation results (37)
Appendix A Original Record Format (38)
Introduction
JJF 1016 "Guidelines for the Compilation of Outlines of Evaluation of Measuring Instruments", JJF 1059.1-2012 "Measurement Uncertainty Evaluation
"Determining and expressing" together constitute the basic series of specifications formulated in this outline.
The requirements and methods of the test items in this outline refer to GB/T 17614.1-2015 "Industrial Process Control System
Transmitter Part 1.Performance evaluation method, GB/T 28474.1-2012 "Industrial process measurement and control system"
Prepared with pressure/differential pressure transmitter Part 1 General Technical Conditions" and JJG882 "Pressure Transmitter". Simultaneously
It also refers to GB/T 18271 "General Performance Evaluation Methods and Procedures of Process Measurement and Control Devices",
GB/T 17212 "Terms and definitions of industrial process measurement and control", GB/T 17626 "Electromagnetic compatibility test and
Measurement Technology", GB/T 2423.2 "Electrical and Electronic Products Environmental Test Part 2.Test Method Test B.
High temperature" and other regulatory documents.
This outline is published for the first time.
Type evaluation outline of pressure transmitter
1 Scope
This outline is applicable to pressure with classification code 12340500 (including positive pressure, negative pressure, differential pressure and absolute pressure)
The type evaluation of the transmitter is not suitable for pneumatic transmitters and force (moment) balanced transmitters.
2 Reference documents
The outline refers to the following documents.
JJG882 pressure transmitter
JJF 1001 General Measurement Terms and Definitions
GB/T 2423.2 Environmental Test for Electrical and Electronic Products Part 2.Test Method Test B. High Temperature
GB/T 17212 Industrial Process Measurement and Control Terms and Definitions
GB/T 17614.1-2015 Industrial Process Control System Transmitter Part 1.Performance Evaluation Method
GB/T 17626 EMC test and measurement technology
GB/T 18271.2 General performance evaluation methods and procedures for process measurement and control devices Part 2.Reference
Test under specific conditions
GB/T 18271.3 General performance evaluation methods and procedures for process measurement and control devices. Part 3.Effects
Loudness test
GB/T 28474.1-2012 Pressure/differential pressure transmitters for industrial process measurement and control systems Part 1
General technical conditions
For dated reference documents, only the dated version applies to this specification; for those without date references
The latest version (including all amendments) is applicable to this specification.
3 Terms and definitions
3.1 Consistency conformity
The degree of agreement between the calibration curve and the specified characteristic curve (straight line, logarithmic curve, parabola, etc.).
[GB/T 17212,P2.2.2.12]
3.2 Independent consistency independentconformity
The calibration curve of the transmitter can be adjusted to be close to the specified characteristic curve, so that the maximum deviation is the smallest when it is the same
degree.
[GB/T 17212,P2.2.2.13]
3.3 Terminal-based conformity
The calibration curve of the transmitter can be adjusted to be close to the specified characteristic curve, so that the range of the two curves of input and output
The degree of agreement between the upper limit and the lower limit of the range.
[GB/T 17212,P2.2.2.14]
3.4 Zero-based conformity
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1789-2019_English be delivered?Answer: Upon your order, we will start to translate JJF 1789-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1789-2019_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1789-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|