HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1780-2019 English PDF

US$559.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1780-2019: Program of Pattern Evaluation of Non-contact Tonometers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1780-2019English559 Add to Cart 5 days [Need to translate] Program of Pattern Evaluation of Non-contact Tonometers Valid JJF 1780-2019

PDF similar to JJF 1780-2019


Standard similar to JJF 1780-2019

JJF 1943   GB/T 36126   GB/T 1885   JJF 1776   JJF 1781   JJF 1775   

Basic data

Standard ID JJF 1780-2019 (JJF1780-2019)
Description (Translated English) Program of Pattern Evaluation of Non-contact Tonometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Classification of International Standard 17.100
Word Count Estimation 24,213
Date of Issue 2019
Date of Implementation 2020-03-31
Issuing agency(ies) State Administration for Market Regulation

JJF 1780-2019: Program of Pattern Evaluation of Non-contact Tonometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Non-contact Tonometers National Measurement Technical Specification of the People's Republic of China Outline of Type Evaluation of Non-Contact Tonometer Published on December 31,.2019 2020-03-21 Implementation Issued by the State Administration of Market Supervision and Administration Outline of Type Evaluation of Non-Contact Tonometer Centralized unit. National Pressure Measurement Technical Committee Main drafting unit. Shanghai Institute of Metrology and Testing Technology Chinese Academy of Metrology This specification entrusts the National Pressure Measurement Technical Committee to interpret The main drafters of this specification. Zhang Zhongli (Shanghai Institute of Metrology and Testing Technology) Zhu Jianping (Chinese Academy of Metrology) Wang Can (Shanghai Institute of Metrology and Testing Technology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terms and definitions (1) 4 Overview (1) 5 Legal management requirements (2) 5.1 Unit of measurement (2) 5.2 Marks and logos (2) 5.3 External structure design requirements (2) 5.4 Technical information that the applicant should submit (2) 6 Measurement requirements (3) 6.1 Indication error (3) 6.2 Repeatability (3) 7 General technical requirements (3) 7.1 Appearance (3) 7.2 Functional requirements (3) 7.3 Range of mechanical motion (3) 7.4 Environmental adaptability (3) 7.5 Electromagnetic compatibility (4) 8 Type evaluation item table (4) 9 Provide the number of prototypes and how to use them (4) 9.1 Number of test prototypes (4) 9.2 Use of prototype (4) 10 Test conditions and methods (4) 10.1 Reference environmental conditions for type evaluation (4) 10.2 Range of mechanical motion (5) 10.3 Indication error (5) 10.4 Repeatability (6) 10.5 Rated working low temperature test (6) 10.6 Rated working high temperature test (7) 10.7 Rated working damp heat test (8) 10.8 Electromagnetic compatibility (8) 11 Judgment principles for type evaluation results (9) 12 Table of measuring instruments and equipment used in the test project (9) Appendix A Non-contact Tonometer Type Evaluation Record Format (11)

Introduction

This type evaluation outline is based on JJG1143-2017 "Non-Contact Tonometer" and refers to ISO 8612..2009 "Ophthalmology tonometer" was developed. JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1015-2014 "General Specification for Type Appraisal of Measuring Instruments", JJF 1016-2014 "Guidelines for Compiling Outlines of Type Appraisal of Measuring Instruments", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the work to support the formulation of this type of evaluation outline The basic series of documents. This specification is the first release. Outline of Type Evaluation of Non-Contact Tonometer

1 Scope

This type evaluation program is applicable to the type evaluation of the non-contact tonometer with air-jet measurement method.

2 Reference documents

This specification refers to the following documents. JJG1143-2017 non-contact tonometer GB 4824-2013 Industrial, Scientific and Medical (ISM) Radio Frequency Equipment Disturbance Characteristics Limits and Measurements method GB 9706.1-2007 Medical electrical equipment Part 1.General requirements for safety GB/T 14710-2009 Environmental requirements and test methods for medical appliances YY0505-2012 Medical electrical equipment Part 1-2.General requirements for safety Parallel standards. Electromagnetic and Capacity requirements and testing ISO 8612..2009 Ophthalmic instruments tonometer (Ophthalmicinstruments-Tonometers) For dated reference documents, only the dated version is applicable to this type of evaluation outline; those that are not dated The latest version (including all amendments) of the cited documents is applicable to this type evaluation outline.

3 Terms and definitions

The following terms and definitions apply to this type of evaluation outline. 3.1 intraocular pressure; IOP The pressure in the eyeball, referred to as intraocular pressure. The unit is kilopascal (kPa). [ISO 8612..2009, definition 3.1] 3.2 Standard analog human eye referencephantomofIOP It has been traced back to the simulated human eye in SI units, and is used as the reference standard for the tonometer's intraocular pressure indication. 3.3 Reference standard IOP pressureofreferencephantomofIOP The standard obtained through the traceability of the value simulates the overall standard intraocular pressure of the human eye.The sources of pressure include the influence of the cornea. Inside, it is not just the nominal pressure of the internal pressure sensing element that simulates the human eye.

4 Overview

Non-contact tonometer (hereinafter referred to as tonometer) is an instrument for measuring intraocular pressure, mainly used for intraocular pressure screening, Using the Imber-Fick principle, a controlled air pulse is used to squeeze the center of the cornea to deform the cornea, and The light beam reflected by the cornea is detected by a photodetector until the cornea is flattened to a diameter range of about 3.6mm At that time, the light energy it received also reached the maximum value, and the pressure of the air pulse was equal to the intraocular pressure. How it works As shown in Figure 1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1780-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1780-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1780-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1780-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.