HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 1456-2014 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1456-2014: Calibration Specification for Optical Degree of Polarization Meter for Telecommunications
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1456-2014English419 Add to Cart 3 days [Need to translate] Calibration Specification for Optical Degree of Polarization Meter for Telecommunications Valid JJF 1456-2014

PDF similar to JJF 1456-2014


Standard similar to JJF 1456-2014

JJG 879   JJF 1106   JJG 810   JJF 2003   JJF 2002   JJF 1912   

Basic data

Standard ID JJF 1456-2014 (JJF1456-2014)
Description (Translated English) Calibration Specification for Optical Degree of Polarization Meter for Telecommunications
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A60
Classification of International Standard 17.180
Word Count Estimation 18,198
Date of Issue 4/21/2014
Date of Implementation 7/21/2014
Quoted Standard JJG 965
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 47 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard specifies the communication light polarization tester (wavelength range of 800 nm ~ 1650 nm) for calibration. Other instruments include the degree of polarization calibration test functions can be performed with reference to this standard. C

JJF 1456-2014: Calibration Specification for Optical Degree of Polarization Meter for Telecommunications


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Optical Degree of Polarization Meter for Telecommunications People's Republic of China National Metrology Technical Specifications Communication optical polarization tester calibration specification Issued on. 2014-04-21 2014-07-21 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Communication optical polarization tester calibration specification Focal point. the National Technical Committee on Optical metrology The main drafting units. China Institute of Metrology China Electronics Technology Group Corporation Research Institute 11 Participated in the drafting. the Shaanxi Provincial Institute of Metrology This specification committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this specification. Xu Nan (China Institute of Metrology) Zhang Zhixin (China Institute of Metrology) Fee Feng (China Electronics Technology Group Corporation Research Institute 11) Drafters participate. Wangheng Fei (China Electronics Technology Group Corporation Research Institute 11) Li Jianwei (China Institute of Metrology) Li Yi (Shaanxi Provincial Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 degree of polarization (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 shows the degree of polarization error (2) 5.2 degree of polarization measurement repeatability (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (3) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration before the test (4) 7.3 Calibration preparation (4) 7.4 shows the degree of polarization error (4) 7.5 degree of polarization measurement repeatability (5) 8 calibration results (6) 9 Recalibration interval (6) Appendix A calibration original record format (7) Appendix B Calibration Certificate page format (9) Appendix C Measurement Uncertainty instance (10)

Introduction

JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common terminology and measurement Definitions ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement group "constitute the present norm-setting The foundation of the series specifications. The calibration specifications for the first release. Communication optical polarization tester calibration specification

1 Scope

This specification applies to optical communication polarization tester (wavelength range of 800nm ~ 1650nm) calibration. its He contains the degree of polarization instrument calibration test functions can be performed with reference to this specification. The degree of polarization of the communication optical tester optical power Rate parameter calibration can be performed with reference to JJG965 "communication power meter." 2. References This specification refers to the following documents. JJG965 communicate with power meter For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

3.1 degree of polarization degreeofpolarization Beam polarized in the total optical power in proportion. NOTE. According to the "Principles of Optics" (Fifth Edition; M Bonn, E Waugh ear Cardiff Science Press .1978.) 10.8.2 in the polarization Degree by equation (1) is given by. DOP = Pp (1) Where. DOP --- degree of polarization; Pp --- polarized part of the optical power, mW; P --- total optical power, mW. Optical power is usually exported manufactured in watts (W) series characterized by international units, engineering general milli dB (DBm) represents the magnitude of the power. These two units by Equation (2) Conversion. PdBm = 10lg (PmW/1mW) (2) Where. PdBm --- magnitude value in dBm power units; PmW --- magnitude value in mW power units.

4 Overview

Polarization optical communication tester is the instrument used to measure the degree of polarization of the optical communication band. Currently optical communication polarization Methods of measurement tester mainly two. Stokes vector method and extreme value method. Stokes law is the basic side

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1456-2014_English be delivered?

Answer: Upon your order, we will start to translate JJF 1456-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1456-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1456-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.