US$949.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1369-2012: Program of Pattern Evaluation of Compressed Natural Gas Dispensers Status: Valid JJF 1369: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1369-2012 | English | 949 |
Add to Cart
|
7 days [Need to translate]
|
Program of Pattern Evaluation of Compressed Natural Gas Dispensers
| Valid |
JJF 1369-2012
|
JJF 1369-1995 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Operating technical norm angle primary standard (angle betten two lines)
| Obsolete |
JJF 1369-1995
|
PDF similar to JJF 1369-2012
Basic data Standard ID | JJF 1369-2012 (JJF1369-2012) | Description (Translated English) | Program of Pattern Evaluation of Compressed Natural Gas Dispensers | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.120 | Word Count Estimation | 41,457 | Older Standard (superseded by this standard) | JJG 996-2005 | Quoted Standard | GB 4943.1-2011; GB/T 17626.2; GB/T 17626.3; GB/T 17626.4; GB/T 17626.5; GB/T 17626.11; GB 18047; GB/T 19236; GB/T 19237; GB/T 2423.1; GB/T 2423.2; GB/T 2423.4; GB 50156; OIML R139-2007 (E) | Adopted Standard | OIML R139-2007(E), NEQ | Regulation (derived from) | AQSIQ Announcement No. 199 of 2012 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to compressed natural gas filling machine (hereinafter referred to as dispensers) for type evaluation. |
JJF 1369-2012: Program of Pattern Evaluation of Compressed Natural Gas Dispensers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Program of Pattern Evaluation of Compressed Natural Gas Dispensers
People's Republic of China National Metrology Technical Specifications
CNG filling machine type evaluation outline
Issued on. 2012-12-03
2013-06-03 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
CNG filling machine type evaluation outline
Instead of JJG996-2005
Appendix A type evaluation outline
Focal point. the National Technical Committee on Metering flow capacity
Main drafting unit. Chongqing Institute of Metrology and Quality Inspection
Beijing Institute of Metrology detection
Participated in the drafting unit. China Testing Technology Research Institute
Shandong Province Institute of Metrology
Jiangsu Province Institute of Metrology
This specification flow capacity commissioned the National Technical Committee responsible for the interpretation of measurement
The main drafters of this specification.
Zhang Zehong (Chongqing Institute of Metrology and Quality Inspection)
Qining Wu (Chongqing Institute of Metrology and Quality Inspection)
Yangyou Tao (Beijing Institute of Metrology detection)
Drafters participate.
Liu Dongsheng (China Testing Technology Research Institute)
Wang Shuo (Chongqing Institute of Metrology and Quality Inspection)
Yao by country (in Shandong Province Institute of Metrology)
Maming Gang (Jiangsu Province Institute of Metrology)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 Terms (1)
4 Overview (2)
4.1 structure (2)
4.2 works (3)
5 legal management requirements (3)
5.1 units of measurement (3)
5.2 marks, and logos (3)
5.3 Design of the external structure (4)
6 metering performance requirements (4)
6.1 The maximum permissible error (4)
6.2 Repeatability (4)
6.3 filling machine turndown ratio (4)
6.4 Minimum measured (4)
6.5 Amount Paid error (4)
7 General technical requirements (4)
7.1 appearance, random file and main features (4)
7.2 Security features (6)
7.3 environmental adaptability (6)
7.4 Durability Test (8)
8 types of evaluation items (8)
Test methods and test conditions 9 items (8)
9.1 Test conditions (8)
9.2 Legal Requirements management inspection (10)
9.3 appearance of random files and check main features (10)
9.4 Safety performance test (11)
9.5 metrological performance test (13)
9.6 environmental adaptability test (16)
Durability Test 9.7 (21)
Determination (22) 10 type of evaluation results
10.1 Single determination principle (22)
10.2 Comprehensive decision rules (22)
Appendix A mass Gas Flow Standard Device (23)
Appendix B Without limiting protection function dispenser (25)
Appendix C type evaluation original record format (26)
Appendix D to select the number of prototypes and products (34)
Introduction
This outline is based on the national standard GB/T 19237-2003 "car with compressed natural gas filling machine" and the international rule of law
Metrology (OIML) International Recommendation R139.2007 (E) "vehicle compressed gaseous fuel measuring systems" (Com-
pressedgaseousfuelmeasuringsystemsforvehicles) as a technical basis, combined with our filling machines
Industry status quo, to JJG996-2005 "CNG refueling machine" A "type of evaluation items and test methods" Appendix
Subject to revisions. With international recommendations on the main technical indicators, national equivalents.
The Memorandum and JJG996-2005 in A "type of evaluation items and test methods" Compared appendix, the main technical change
Of the following.
--- Increased by large, medium and small flow filling machine terminology;
--- Modify the nameplate of measuring instruments, increasing the minimum content to be measured;
--- Modified with a pressure limiting protection structure and working principle function filling machine;
--- Increase the structure and working principle without pressure limiting protection filling machine;
--- Increasing the flow of medium and small filling machine is the smallest measurement requirements;
--- Modify the voltage limiting protection pressure range;
--- Cancel the solenoid valve off test;
--- Modify the type evaluation test specification standard equipment;
--- Modify the quality of the Gas Flow Standard device parameters associated equipment;
--- An increase of non-reference conditions and reference conditions during pattern evaluation tests;
--- Modify the measurement accuracy test (flow range, data processing, etc.);
--- Modified test measured minimum number of measurements and data processing;
--- Modified durability test methods and requirements;
--- Modify the power adaptability test;
--- Modify the original record format type evaluation.
CNG filling machine type evaluation outline
1 Scope
This type of evaluation outline is applied to compressed natural gas filling machine (hereinafter referred to as filling machine) pattern evaluation.
2. References
GB 4943.1-2011 Safety of information technology equipment - Part 1. General requirements
GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test
GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5 electromagnetic compatibility test and measurement technology surge (impact) immunity test
GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations
Immunity Test
GB 18047 CNG
GB/T 19236 cars with compressed natural gas dispensing nozzles
GB/T 19237 Automotive CNG refueling machine
GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.4 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. alternating wet
Thermal (12h 12h cycle)
GB 50156 car design and construction of refueling stations
OIMLR139.2007 (E) vehicle compressed gaseous fuel measuring systems (Compressedgaseousfuel
measuringsystemsforvehicles)
These documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this outline. However, the drum
Reed whether the latest versions of these files according to the parties that this outline agreement. Those who do not note cited date
Use, the latest versions apply to this outline.
3 Terms
3.1 CNG refueling machine compressednaturalgas (CNG) dispenser
CNG filling the gas container, with special equipment and devices such as metering and pricing. It comprises a mass
Meter, electronic meter controller, quick disconnect valve, dispensing nozzles and the like.
3.2 meter electronic controller electroniccomputer
Computing and control means filling machine. May receive transmitted flow meter signal and voltage limiting transmission to the sensor
Pressure signal, according to pre-set and filling machine parameters for computing and processing; you can transfer data and display operation
Make, and automatically determine and control the flow of gas.
Note. The electronic meter controller to achieve the main function indication indicator, zeroing, adjust function, indicating the amount paid functions.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1369-2012_English be delivered?Answer: Upon your order, we will start to translate JJF 1369-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1369-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1369-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJF 1369-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1369-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|