HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1260-2010 English PDF

US$529.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1260-2010: Calibration specification for baby incubator
Status: Valid

JJF 1260: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1260-2010English529 Add to Cart 4 days [Need to translate] Calibration specification for baby incubator Valid JJF 1260-2010
JJF 1260-1990English239 Add to Cart 2 days [Need to translate] O.T.N. of the Primary Standard for the High Frequency Vibration Obsolete JJF 1260-1990

PDF similar to JJF 1260-2010


Standard similar to JJF 1260-2010

JJF 1016   JJF 1059.1   JJF 1071   JJF 1261.6   JJF 1261.9   JJF 1261.5   

Basic data

Standard ID JJF 1260-2010 (JJF1260-2010)
Description (Translated English) Calibration specification for baby incubator
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A50
Classification of International Standard 17.020
Word Count Estimation 23,293
Date of Issue 2010-06-10
Date of Implementation 2010-09-10
Quoted Standard GB 9706.1-2007; GB 11243-2008; JJG 535-2004; JJF 1001-1998; JJF 1071-2000; JJF 1101-2003
Regulation (derived from) AQSIQ Announcement No. 59 of 2010
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the use of air control work ju degrees infant incubator performance measurement calibration. This specification does not apply to the use of radiant heat on the baby warm, open incubator, use of baby skin temperature control and transfer of baby incubators work with children playing style forwarding infant incubator.

JJF 1260-2010: Calibration specification for baby incubator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for baby incubator People's Republic of China National Metrology Technical Specifications Infant Incubator calibration specifications Issued on. 2010-06-10 2010-09-10 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Infant Incubator calibration specifications forBaby Incubator This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on June 10, 2010, and from From September 10, 2010 into effect. Focal point. the National Technical Committee on Clinical Measurement Drafting units. China Institute of Metrology Supervision and Testing Nanjing hospital This specification measured by the National Technical Committee responsible for the interpretation of clinical medicine Drafters of this specification. Chen Jing (China Institute of Metrology) Hu Ning (Nanjing Supervision and Testing Institute) Liu Feng (Nanjing Supervision and Testing Institute) Shao micro dimension (Nanjing Supervision and Testing Institute)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Terms (1) 4 Overview (2) 5 Metrological characteristics (2) Temperature deviation 5.1 (2) 5.2 Temperature uniformity (2) 5.3 Temperature fluctuation (2) 5.4 average incubator temperature and the temperature difference between the control (2) 5.5 temperature overshoot (2) 5.6 Relative humidity bias (2) 5.7 oxygen analyzer indication allowable error (2) 5.8 infant cabin noise (2) 5.9 alarm alarm noise (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 load condition (2) 6.3 Measurement standard device and other equipment (3) 7 calibration items and calibration methods (3) 7.1 calibration items (3) 7.2 Calibration method (3) Expression 8 calibration results (7) 9 Recalibration interval (7) Appendix A baby incubator temperature deviation Measurement Uncertainty Evaluation (8) Appendix B baby incubator relative humidity deviation Measurement Uncertainty (10) Appendix C oxygen analyzer Indication Error Uncertainty Evaluation (12) Appendix D infant incubator Noise Measurement Uncertainty (14) Appendix E infant incubator calibration records reference format (16) Appendix F calibration certificate contents (18) Infant Incubator calibration specifications

1 Scope

This instruction applies to performance measurement calibration using air temperature control works infant incubator. This specification does not apply to the use of radiant heat to warm the baby open incubator, the use of infant skin temperature control Infant incubator and transfer babies manner of transfer formula with infant incubator.

2 Citations

GB 9706.1-2007 Medical electrical equipment - Part 1. General Requirements for Safety GB 11243-2008 Medical electrical equipment - Part 2. Particular requirements for safety of baby incubators JJG535-2004 zirconia oxygen analyzer test procedures JJF 1001-1998 common measurement terms and definitions JJF 1071-2000 National Calibration Specifications writing rules JJF 1101-2003 environmental testing equipment temperature, humidity calibration specification When using this specification it should be noted that using the currently valid version of the documents cited.

3 Terms

3.1 infant cabin babycompartment An environmentally controlled housing, for receiving a baby, and having observed part of the baby. 3.2 temperature control controltemperature On the temperature controller set temperature. 3.3 incubator temperature incubatortemperature Air temperature measured at 10cm above the infant compartment mat surface of the center (see point A 1's). 3.4 steady state temperature steadytemperaturecondition In 1h interval, the incubator temperature does not exceed the time of 1 ℃ state. 3.5 average incubator temperature averageincubatortemperature When steady state temperature, the temperature of the incubator evenly spaced reading average. 3.6 temperature deviation temperaturedeviation In the steady state temperature, the display and the average temperature difference between the average temperature of the incubator. 3.7 Temperature uniformity temperatureuniformity Infant Incubator temperature measurement points B, C, D and E four o'clock every point average temperature and average temperature incubator The difference (B, C, D, E point shown in Figure 1). 3.8 Temperature fluctuation temperaturefluctuation In the steady state temperature, the temperature difference between the incubator and the average temperature of the incubator. 3.9 temperature overshoot temperatureovershoot In order to improve the temperature of the incubator, after adjusting temperature control, temperature control the incubator temperature beyond the maximum temperature difference is called

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1260-2010_English be delivered?

Answer: Upon your order, we will start to translate JJF 1260-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1260-2010_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1260-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1260-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1260-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.