US$449.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1030-2023: Measurement and Test Norm of Metrological Characteristics of Thermostatic Baths for Temperature Calibration Status: Valid JJF 1030: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1030-2023 | English | 449 |
Add to Cart
|
4 days [Need to translate]
|
Measurement and Test Norm of Metrological Characteristics of Thermostatic Baths for Temperature Calibration
| Valid |
JJF 1030-2023
|
JJF 1030-2010 | English | 479 |
Add to Cart
|
3 days [Need to translate]
|
Measurement and Test Norm of Thermostatic Baths Metrological Characteristics
| Obsolete |
JJF 1030-2010
|
JJF 1030-1998 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Measurement and Test Norm of Thermostatic BathTechnological Characteristic
| Obsolete |
JJF 1030-1998
|
JJF 1030-1991 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Chinese Industry Standard)
| Obsolete |
JJF 1030-1991
|
PDF similar to JJF 1030-2023
Standard similar to JJF 1030-2023 JJG 1030 JJF 1050 JJF 2051 JJF 1033
Basic data Standard ID | JJF 1030-2023 (JJF1030-2023) | Description (Translated English) | Measurement and Test Norm of Metrological Characteristics of Thermostatic Baths for Temperature Calibration | Sector / Industry | Metrology & Measurement Industry Standard | Word Count Estimation | 22,278 | Date of Issue | 2023-10-12 | Date of Implementation | 2024-04-12 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1030-2023: Measurement and Test Norm of Metrological Characteristics of Thermostatic Baths for Temperature Calibration ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Technical Specifications of the People's Republic of China
Thermostatic bath for temperature calibration
Technical Performance Test Specifications
Released on 2023-10-12
Implemented on 2024-04-12
Released by the State Administration for Market Regulation
Thermostatic bath for temperature calibration
Technical Performance Test Specifications
Replace JJF 1030-2010
Responsible unit: National Thermometry Technical Committee
Main drafting unit: Beijing Institute of Metrology and Testing Sciences
Unit participating in the drafting: Dalian Institute of Metrology, Inspection and Testing Co:, Ltd:
China Jiliang University
Jinan Changfeng Zhiyuan Instrument Technology Co:, Ltd:
Dalian Bokong Technology Co:, Ltd:
Huzhou Weili Instrument Factory
The National Thermometry Technical Committee is entrusted with the interpretation of this specification:
The main drafters of this specification:
Zhang Ke (Beijing Institute of Metrology and Testing Sciences)
Participating drafters:
Li Ying (Dalian Institute of Metrology, Inspection and Testing Co:, Ltd:)
Sun Bin(China Jiliang University)
Zhang Jiong (Jinan Changfeng Zhiyuan Instrument Technology Co:, Ltd:)
Yao Min (Beijing Institute of Metrology and Testing Sciences)
Zeng Yongchun (Dalian Bokong Technology Co:, Ltd:)
Chen Jian (Huzhou Weili Instrument Factory)
Table of contents
Introduction(Ⅱ)
1 Scope(1)
2 Cited documents(1)
3 terms(1)
4 Overview(2)
5 Technical performance(2)
6 Test conditions(3)
6:1 Environmental conditions(3)
6:2 Standard instruments and supporting equipment for measurement (3)
7 Test items and test methods (3)
7:1 Test items (3)
7:2 Test method(3)
8 Expression of test results(8)
9 Retest time(8)
Appendix A Thermostatic bath test certificate inner page format (9)
Appendix B Uncertainty evaluation of horizontal temperature difference measurement of constant temperature bath (10)
Appendix C Uncertainty Evaluation Example of Vertical Temperature Difference Measurement in Constant Temperature Bath 1 (12)
Appendix D Uncertainty Evaluation Example 2 of Vertical Temperature Difference Measurement of Constant Temperature Bath (14)
Introduction
JJF 1071-2010 "Rules for Writing National Measurement Calibration Specifications", JJF 1059:1-2012 "Measurement Uncertainty
Assessment and Expression" together constitute the basic series of standards that support the formulation and revision of this standard:
This specification replaces JJF 1030-2010 "Technical Performance Test Specification for Constant Temperature Baths":
Compared with JJF 1030-2010, in addition to editorial modifications, the main technical changes in this specification are as follows:
---According to the current temperature measurement regulations and specification requirements, add -80℃~300℃ to the range;
---According to the current temperature measurement regulations and specification requirements, increase the technical performance indicators of the constant temperature bath;
---Add the term "immersion depth";
---Based on the technical index requirements of the constant temperature bath, it is clear that the minimum immersion depth of the standard platinum resistance thermometer is 100mm;
---Add test items for temperature rise and cooling rate deviation of constant temperature bath:
The previous releases of this specification are as follows:
---JJF 1030-2010;
---JJF 1030-1998:
Thermostatic bath for temperature calibration
Technical Performance Test Specifications
1 Scope
This specification applies to the temperature uniformity,
Test of temperature fluctuation and heating (cooling) rate:
2 cited documents
This specification references the following documents:
JJG130-2011 Working glass liquid thermometer
JJG229-2010 Industrial platinum and copper thermal resistance
JJG310-2002 pressure thermometer
JJF 1379-2012 Calibration specifications for thermistor thermometers
JJF 1632-2017 Temperature switch temperature parameter calibration specifications
For dated references, only the dated version applies to this specification; for undated references, only the dated edition applies:
The latest version (including all modification orders) shall be applicable to this specification:
3 terms
An area that can ensure the temperature uniformity and fluctuation of the thermostatic bath:
The difference between the maximum temperature and the minimum temperature in the working area of the thermostatic bath under stable conditions:
When the constant temperature bath is in a stable state, the maximum temperature change in the working area within a certain time interval:
The horizontal plane at the highest point of the thermostatic bath working area:
The horizontal plane at the lowest point of the thermostatic bath working area:
3:6 fixedthermometer fixedthermometer
A thermometer fixed in the working area of the constant temperature bath and used to measure the temperature of the constant temperature bath:
3:7 movedthermometer
Thermometers placed at multiple predetermined positions within the working area of the constant temperature bath for measuring the temperature of the constant temperature bath:
3:8 immersion depth immersiondepth
The thermometer is inserted vertically into the thermostatic bath, the length of which it is immersed in the liquid:
|