US$519.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JG/T 431-2014: Cylindrical fresh air handling units Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JG/T 431-2014 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
Cylindrical fresh air handling units
| Valid |
JG/T 431-2014
|
PDF similar to JG/T 431-2014
Basic data | Standard ID | JG/T 431-2014 (JG/T431-2014) | | Description (Translated English) | Cylindrical fresh air handling units | | Sector / Industry | Building & Construction Industry Standard (Recommended) | | Classification of Chinese Standard | P48 | | Classification of International Standard | 91.140.30 | | Word Count Estimation | 20,232 | | Date of Issue | 4/9/2014 | | Date of Implementation | 8/1/2014 | | Quoted Standard | GB/T 9068; GB/T 14294-2008; GB/T 14295; GB/T 14296; GB/T 16538; GB/T 16803; GB/T 21087 | | Regulation (derived from) | Housing and Urban-Rural Construction Notice No. 373; industry standards filing Notice 2014 No. 6 (No. 174 overall) | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | | Summary | This Standard specifies the terms and definitions of new air conditioning unit circle, classification and marking, materials, requirements, test methods, inspection rules, marking, packaging, transport and storage. This Standard applies to refrigerant for |
JG/T 431-2014: Cylindrical fresh air handling units---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cylindrical fresh air handling units
ICS 91.140.30
P48
People's Republic of China building industry standards
Round fresh air conditioning unit
2014-04-09 released
2014-08-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 classification and marking 2
5 material 3
6 Requirements 3
7 Test Method 8
Inspection rules 12
9 logo, packaging, transportation and storage 13
Appendix A (Normative) Air conditioning unit box heat transfer coefficient test method 15
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Construction Environment and Energy Standardization Technical Committee.
This standard is drafted by. Jiangsu Aeolus Air Conditioning Group Co., Ltd.
Participated in the drafting of this standard. China Academy of Building Research, Beijing Institute of Architectural Design Co., Ltd., China Architectural Design Research
Institute, Nanjing Architectural Design and Research Institute Co., Ltd., East China Architectural Design and Research Institute, China International Engineering Co., Ltd. yuan, Shanghai Jiaotong
Tong University, Jiangsu wind blowing air conditioning and purification equipment Engineering Research Center Co., Ltd., Shanghai Tuo Er Technology Development Co., Ltd. and so on.
The main drafters of this standard. Lu Hui, Xu Wei, Xu Hongqing, Song Xiaochun, Zhang Jianzhong, Ma Weijun, Li Zhaoxuan, Gu Bo, Wang Zhichao, Guo Wei, Ding Huanqing,
Huang Jian, Shen Ju, Weipeng Feng.
Round fresh air conditioning unit
1 Scope
This standard specifies the circular fresh air conditioning unit terms and definitions, classification and marking, materials, requirements, test methods, inspection rules, standard
Log, packaging, transportation and storage.
This standard applies to the refrigerant for the cold water, heat medium for hot water or steam to the function of the unit for the combination of units, to complete the transport, heating, cooling,
Humidification, dehumidification, filtration, muffler, heat recovery and other functions of the circular fresh air conditioning unit. Round air conditioning unit with return air mixing section, section
Near the circular air conditioning units, ethylene glycol and other refrigerant circular air conditioning units can refer to use.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 9068 Heating, ventilation and air conditioning equipment - Determination of noise power level - Engineering
Combined air conditioning unit
GB/T 14295 air filter
GB/T 14296 air coolers and air heaters
GB/T 16538 Acoustics sound pressure method for the determination of sound power level noise level comparison method
GB/T 16803 Heating, ventilation, air conditioning, cleaning equipment terminology
GB/T 21087 air-air energy recovery device
3 Terms and definitions
GB/T 16803 defined and the following terms and definitions apply to this document.
3.1
Cylindrical shape, airflow cross section are circular by a variety of air handling function of a combination of air handling equipment.
3.2
Unit air handling functional section functionalsectionofunits
Has the air to carry out one or several processing unit.
[GB/T 14294-2008, Definition 3.2]
Note. The unit air handling section has air mixing, flow, filtration, cooling, primary and secondary heating, dehumidification, humidification, blower, return air blower,
Heat recovery unit.
3.3
Rated air flow rateairflowrate
Under standard air condition, air volume flow through the unit per unit of time.
[GB/T 14294-2008, Definition 3.3]
3.4
External static pressure externalstaticpressure
After the unit overcame its own resistance under rated air volume, the unit pressure difference between inlet and outlet of the unit.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JG/T 431-2014_English be delivered?Answer: Upon your order, we will start to translate JG/T 431-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JG/T 431-2014_English with my colleagues?Answer: Yes. The purchased PDF of JG/T 431-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|