HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GBZ24844-2009 English PDF

US$559.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ24844-2009: Technical specification for oil-immersed shunt reactor of 1000kV AC system
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/Z 24844-2009English559 Add to Cart 3 days [Need to translate] Technical specification for oil-immersed shunt reactor of 1000kV AC system Obsolete GB/Z 24844-2009

PDF similar to GBZ24844-2009


Standard similar to GBZ24844-2009

GB/T 19212.5   GB/T 10228   GB/T 25095   GB/T 16896.1   GB/T 16896.3   GB/T 24844   

Basic data

Standard ID GB/Z 24844-2009 (GB/Z24844-2009)
Description (Translated English) Technical specification for oil-immersed shunt reactor of 1000kV AC system
Sector / Industry National Standard
Classification of Chinese Standard K40
Classification of International Standard 29.040.10
Word Count Estimation 14,144
Date of Issue 2009-11-30
Date of Implementation 2010-05-01
Quoted Standard DL/T 1094; GB 1094.1; GB 1094.2; GB 1094.3; GB 2536; GB/T 10229-1988; GB/T 1094.10; GB/T 1094.4; GB/T 2900.15; GB/T 5273; IEC 60076.6; JB/T 501
Regulation (derived from) ?National Standard Approval Announcement 2009 No.14 (Total No.154)
Issuing agency(ies) Ministry of Health of the People's Republic of China
Summary This standard specifies the 1000 kV AC system with oil-immersed shunt reactor performance parameters, technical requirements, tests and signs, requirements and other aspects of packaging and transportation. The technical guidance document applies to the voltage rating of the AC 1000 kV, rated capacity of 200 Mvar-320 Mvar, single-phase oil-immersed shunt reactor products.

GBZ24844-2009: Technical specification for oil-immersed shunt reactor of 1000kV AC system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specicaltion for oil-immersed shunt reactor of 1000kV AC system ICS 29.240.10 K40 People's Republic of China national standardization of technical guidance documents 1000 犽 犞 AC system with oil-immersed shunt reactor specifications Posted.2009-11-30 2010-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Conditions of use 1 5 performance parameters 2 6 technical requirements 4 7 Test 5 8 logo, packaging, transportation 8 Appendix A (normative) 1000kV AC oil-immersed shunt reactor neutral point reactor 9

Foreword

Appendix A of this Guidance Document is a normative appendix. This Guidance Document is proposed by China Electricity Council. This Guidance Document is administered by China Electricity Council. The guidance of technical documents by the UHV AC Transmission Standardization Technical Committee, State Grid Electric Power Research Institute responsible for the interpretation. The guidance of technical documents drafted by. State Grid Corporation, State Grid Electric Power Research Institute. Participated in the drafting of this technical documents. Shenyang Transformer Research Institute, China Electric Power Research Institute, TBEA Shenyang Transformer Group Co., Ltd., Xi'an West Transformer Co., Ltd., Baoding Tianwei change Electric Co., Ltd.. The main drafters of this Guidance Document are Sun Xin, Wu Zhirong, Ding Yang, Guo Huihao, Wang Shaowu, Li Guangfan, Wang Xiaoning, Zhong Juntao, 宓 Dragon, Liu Dongsheng, Wang Ninghua, Zhang Zhongguo.

Introduction

In order to meet the future construction of UHV AC engineering needs, clear and standardized 1000kV AC system with oil-immersed shunt reactors Technical requirements, special formulation of the guidance of technical documents. The guidance of technical documents is combined with China's 1000kV UHV AC pilot demonstration project of equipment development and construction, and reference Based on the existing standards and operating experience of EHV shunt reactors at home and abroad. 1000 犽 犞 AC system with oil-immersed shunt reactor specifications

1 Scope

This Guidance Document stipulates the performance parameters, technical requirements, test and test of oil-immersed shunt reactors for 1000kV AC system Logo, packaging and shipping requirements. The guidance of technical documents for the voltage level AC 1000kV, rated capacity.200Mvar ~ 320Mvar, single-phase oil-immersed Shunt reactor products.

2 Normative references

The following documents contain provisions which, through reference in this guidance document, constitute provisions of this guidance document. All dated Reference documents, all subsequent amendments (not including errata content), or revisions do not apply to this guidance document, however, encouragement The parties to an agreement based on this Guidance Document are studying whether the latest versions of these documents are applicable and those that are not dated The latest version applies to this guidance document. GB 1094.1 power transformers Part 1 General (GB 1094.1-1996, eqv IEC 60076-1..1993) GB 1094.2 Power Transformer Part 2 Temperature Rise (GB 1094.2-1996, eqv IEC 60076-2..1993) GB 1094.3 Power Transformer Part 3 insulation level, insulation test and external insulation air gap (GB 1094.3-2003, eqv IEC 60076-3..2000) GB/T 1094.4 Power Transformers Part 4 Power Transformers and Reactors Lightning Impulse and Operating Shock Test Guidelines (GB/T 1094.4-2005, IEC 60076-4..2002, MOD) GB/T 1094.10 power transformers Part 10 Determination of sound level (GB/T 1094.10-2003, eqv IEC 60076-10. 2001) GB 2536 transformer oil (GB 2536-1990, neqIEC 60296. 1982) GB/T 2900.15 Electrotechnical terminology Transformers, transformers, voltage regulators and reactors (GB/T 2900.15-1997, neqIEC 60050 (421)..1990, IEC 60050 (321). 1986) GB/T 5273 transformers, high voltage electrical wiring and casing (GB/T 5273-1985, neqIEC 60518. 1975) GB/T 10229-1988 Reactors (neqIEC 60289. 1987) DL/T 1094 Power Transformer with insulating oil selection guide JB/T 501 Power Transformer Test Guidelines IEC 60076.6 Power Transformers Part 6. Reactors

3 Terms and definitions

GB/T 2900.15 and GB/T 10229 established terms and definitions apply to this guidance document.

4 conditions of use

4.1 normal conditions of use 4.1.1 Environmental conditions a) Altitude not exceeding 1000m; b) Ambient temperature.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ24844-2009_English be delivered?

Answer: Upon your order, we will start to translate GBZ24844-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ24844-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ24844-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.