US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 9069-2008: Determination of sound power level for noise emitted by reciprocating pump -- Engineering method Status: Valid GB/T 9069: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 9069-2008 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
Determination of sound power level for noise emitted by reciprocating pump -- Engineering method
| Valid |
GB/T 9069-2008
|
| GB/T 9069-1988 | English | 879 |
Add to Cart
|
6 days [Need to translate]
|
Determination of sound power level for noise emitted by reciprocating pump--Engineering method
| Obsolete |
GB/T 9069-1988
|
PDF similar to GB/T 9069-2008
Basic data | Standard ID | GB/T 9069-2008 (GB/T9069-2008) | | Description (Translated English) | Determination of sound power level for noise emitted by reciprocating pump -- Engineering method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | J71 | | Classification of International Standard | 23.080 | | Word Count Estimation | 23,287 | | Date of Issue | 2008-06-25 | | Date of Implementation | 2009-02-01 | | Older Standard (superseded by this standard) | GB/T 9069-1988 | | Regulation (derived from) | National Standard Approval Announcement 2008 No.11 (Total No.124) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard provides a reflecting plane under free field conditions sound power level of engineering assays and reverberation room sound power level engineering assay. Determination of sound power levels of interior noise in this standard reverb. Comparison method using standard sound source moves microphone test methods. Multi-point test method, see Appendix A. This standard applies to the determination of sound power levels of noise, including the prime mover, including a reciprocating pump unit (hereinafter referred to as pump units). |
GB/T 9069-2008: Determination of sound power level for noise emitted by reciprocating pump -- Engineering method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of sound power level for noise emitted by reciprocating pump. Engineering method
ICS 23.080
J71
National Standards of People's Republic of China
Replacing GB/T 9069-1988
Determination of sound power level reciprocating pump - Engineering method
Posted 2008-06-25
2009-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 the amount of measurement error and measurement needs of 1
5 2 measurement environment
2 6 test equipment
7 Installation and operation of the pump unit 3
8 SPL measurements 3
9 Calculation of sound power levels 5
10 recordings 6
7 11 test reports
Appendix A (informative) Pump Unit Indoor reverberation sound power level other measuring methods 8
Appendix B (normative) Environmental correction value K is determined 10
The reference body Appendix C (normative) pump unit, the measurement surface, measuring point and several typical pump unit 12 illustrated reference body
Annex D (informative) Determination of record forms and report forms 17
Foreword
This standard is GB/T 9069-1988 "reciprocating pump sound power levels - Engineering method" amendments.
This standard compared with GB/T 9069-1988, the main changes are as follows.
--- Sound Power in the test method standard sound source (comparison), increasing the mobile microphone test method for determining noise reverberation room
Determination of sound power level;
--- Original standard D multi-point test method Appendix to reference.
The Standard Appendix B, Appendix C are normative appendices, Appendix A, Appendix D is an informative annex.
From the date of implementation of this standard instead of GB/T 9069-1988.
The standard proposed by China Machinery Industry Federation.
This standard by the National Standardization Technical Committee pump (SAC/TC211) centralized.
This standard was drafted. Hefei General Machinery Research Institute.
The main drafters of this standard. Linze An.
This standard replaces the standards previously issued as follows.
--- GB/T 9096-1988.
Determination of sound power level reciprocating pump - Engineering method
1 Scope
This standard specifies a reflection on the next plane free-field conditions sound power level of engineering assays and reverberation room sound power
Level engineering assay. Determination of this standard reverberation room sound power level of the sound source using standard mobile microphone comparison test method,
Multi-point test method, see Appendix A.
This standard applies to the determination of sound power levels include a prime mover including a reciprocating pump unit (hereinafter referred to as pump units).
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 3102.7 acoustic quantity and unit (GB 3102.7-1993, eqv ISO 31-7.1992)
GB/T 3241 octave and fractional octave filters
Determination of noise sources GB/T 3767 sound pressure of sound power levels reflecting plane free field engineering method
(GB/T 3767-1996, eqv ISO 3744.1994)
GB electric, acoustic performance and test methods 3785 Sound Level Meter
GB/T 3947 Acoustics Terminology
GB/T 6881.2 Determination of sound pressure Part 1 reverberant field of sound power levels of noise sources for small, movable sources engineering methods
Score. hard walled test rooms comparative method (GB/T 6881.2-2002, ISO 3743-1.1994, IDT)
GB /Determination of sound power levels of noise sources reverberant field for small, movable sources Engineering Method 2 T 6881.3 sound pressure
Part 2. Reverberation chamber method (GB/T 6881.3-2002, ISO 3743-2.1994, IDT)
JJG176 acoustic calibrator verification procedures
JJG188 sound level meter verification procedures
JJG277 sound source standard test procedures
IEC 61183 Electroacoustics - sound level meter shot without predetermined sound field and diffuse sound field correction
3 Terms and Definitions
GB/T 3947 and GB 3102.7 established terms and definitions apply to this standard.
4 Determination of the amount required to error and measurement
4.1 Determination of the amount required
A-weighted sound power level and the center frequency of the seven octave sound power levels between 125Hz ~ 8000Hz.
4.2 Measurement error
Measured in accordance with this standard, A-weighted sound power level of the standard deviation of not more than 2dB; standard deviation octave sound power level is unlikely
Table 1 provides value.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 9069-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 9069-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 9069-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 9069-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 9069-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9069-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|