US$139.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 8151.5-2012: Methods for chemical analysis of zinc concentrates -- Part 5: Determination of lead content -- The flame atomic absorption spectrometric method Status: Valid GB/T 8151.5: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 8151.5-2012 | English | 139 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of zinc concentrates -- Part 5: Determination of lead content -- The flame atomic absorption spectrometric method
| Valid |
GB/T 8151.5-2012
|
| GB/T 8151.5-2000 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods for chemical analysis of zinc concentrates -Determination of lead content
| Obsolete |
GB/T 8151.5-2000
|
| GB/T 8151.5-1987 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Methods for chemical analysis of zinc concentrates--The atomic absorption spectrophotometric method for the determination of lead content
| Obsolete |
GB/T 8151.5-1987
|
PDF similar to GB/T 8151.5-2012
Basic data | Standard ID | GB/T 8151.5-2012 (GB/T8151.5-2012) | | Description (Translated English) | Methods for chemical analysis of zinc concentrates -- Part 5: Determination of lead content -- The flame atomic absorption spectrometric method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | H13 | | Classification of International Standard | 77.120.60 | | Word Count Estimation | 6,658 | | Older Standard (superseded by this standard) | GB/T 8151.5-2000 | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the zinc concentrate Determination of lead content. This section applies to zinc concentrates of lead content. Measuring range: 0. 50 % 6. 00%. |
GB/T 8151.5-2012: Methods for chemical analysis of zinc concentrates -- Part 5: Determination of lead content -- The flame atomic absorption spectrometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS77.120.60
H13
National Standards of People's Republic of China
Replacing GB/T 8151.5-2000
Methods for chemical analysis of zinc concentrates
Part 5. Determination of lead content
Flame Atomic Absorption Spectrometry
Part 5. Determinationofleadcontent-
Issued on. 2013-10-01 2012-12-31 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 8151 "Methods for chemical analysis of zinc concentrates" is divided into 20 parts.
--- Part 1. Determination of the amount of zinc Na2EDTA precipitation titration and extraction separation Na2EDTA titration;
--- Part 2. Determination of sulfur content - Combustion neutralization titration method;
--- Part 3. Determination of iron content Na2EDTA titration;
--- Part 4. Determination of silicon dioxide content - Molybdenum blue spectrophotometric method;
--- Part 5. Determination of lead content by flame atomic absorption spectrometry;
--- Part 6. Determination of copper content - Flame atomic absorption spectrometry;
--- Part 7. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry and potassium bromate titration;
--- Part 8. Determination of cadmium content by flame atomic absorption spectrometry;
--- Part 9. Determination of the amount of fluorine ion selective electrode method;
--- Part 10. Determination of tin content by hydride generation - atomic fluorescence spectrometry;
--- Part 11. Determination of antimony content hydride generation - atomic fluorescence spectrometry;
--- Part 12. Determination of the amount of silver by flame atomic absorption spectrometry;
--- Part 13. Determination of the amount of germanium hydride generation - atomic fluorescence spectroscopy and spectrophotometry Phenylfuoron;
--- Part 14. Determination of nickel content by flame atomic absorption spectrometry;
--- Part 15. Determination of the amount of mercury atomic fluorescence spectrometry;
--- Part 16. Determination of cobalt content by flame atomic absorption spectrometry;
--- Part 17. Determination of the amount of zinc hydroxide precipitation -Na2EDTA titration;
--- Part 18. Determination of the amount of zinc ion exchange -Na2EDTA titration;
--- Part 19. Determination of the amount of gold and silver gray Chuihuo lead analysis or assay and flame atomic absorption spectrometry;
--- Part 20. Copper, lead, iron, arsenic, cadmium, antimony, calcium, magnesium content - Inductively coupled plasma atomic emission spectrometry.
This is Part 5 GB/T 8151's.
Rules in this section in accordance with GB/T 1.1-2009 given draft.
This section arbitration.
This Part replaces GB/T 8151.5-2000 "Methods for chemical analysis of zinc concentrates - Determination of lead content." And GB/T 8151.5-2000
Compared to the main changes are as follows.
--- Dissolving acid with hydrochloric acid to nitric acid;
--- Lead increased from 0.50% to 4.00% expands to 0.50% - 6.00%;
--- Text format has been modified;
--- Added precision and test reports.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. MCC Huludao Nonferrous Metals Group Co., Ltd.
This section drafted by. MCC Huludao Nonferrous Metals Group Co., Ltd.
Participated in the drafting of this section. Kunming Institute of Metallurgy, Hunan Nonferrous Metals Group Co., Ltd. Shuikoushan, Yuguang Gold & Lead Group shares have
Limited, Beijing General Research Institute of Mining and Metallurgy, Bayannaoer Zijin Nonferrous Metals Corporation.
The main drafters of this section. Lawrence Li, Jiang Li, Xi Hongjie, Liu Wei Li, Li Jingjing, Zheng Xueying, Mao Yanling, Kong Jianmin, Zhao, Tangshu Fang,
Liu Chunfeng, Guoxin Ling, Li Qiongli.
This part of the standard replaces the previous editions are.
--- GB/T 8151.5-1987, GB/T 8151.5-2000.
Methods for chemical analysis of zinc concentrates
Part 5. Determination of lead content
Flame Atomic Absorption Spectrometry
1 Scope
This section GB/T 8151 provisions of the determination of zinc concentrate lead content.
This section applies to the determination of zinc concentrate - Determination of lead content range. 0.50% - 6.00%.
2 Method summary
Samples with hydrochloric acid, nitric acid dissolved in dilute nitric acid medium, atomic absorption spectrometer at a wavelength of 283.3nm, air - acetylene flame,
Measuring the absorbance of lead.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical reagent and distilled or deionized water or equivalent purity.
3.1 hydrochloride (ρ1.19g/mL).
Nitrate 3.2 (ρ1.42g/mL).
3.3 nitric acid (11).
3.4 Lead standard solution. Weigh 0.4000g metallic lead (wPb≥99.99%) in 250mL beaker, add 20mL of nitric acid (3.3) cover
Table dish, heated until completely dissolved, to remove nitrogen oxides boil, cooled to room temperature. Transferred 1000mL volumetric flask and dilute to the mark with water, mix
Uniform. This solution 1mL containing 400μg lead.
4 Instrument
Atomic absorption spectrometer, with a lead hollow cathode lamp.
Under instrument conditions, who can achieve the following indicators atomic absorption spectrometer can be used.
--- Characteristic concentration. in the sample solution matrix consistent solution, characterized in lead concentration should not exceed 0.50μg/mL;
--- Precision. the highest concentration of the standard solution with 10 times the absorbance measured, and the standard deviation should not exceed the average absorbance
1.50%; absorbance measured 10 times the minimum concentration of the standard solution (not a "zero" standard solution), and the standard deviation should not exceed
0.50% the highest concentration of the standard average absorbance;
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Ratio of not less than 0.90.
5 Sample
5.1 Samples should sift through the 0.100mm hole.
5.2 Samples previously 105 ℃ ± 5 ℃ baking 1h, cooled to room temperature and placed in the dryer.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 8151.5-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 8151.5-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 8151.5-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 8151.5-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 8151.5-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8151.5-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|