US$359.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37139-2018: Requirements for EMC measurement methods for DC powered equipment Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 37139-2018 | English | 359 |
Add to Cart
|
4 days [Need to translate]
|
Requirements for EMC measurement methods for DC powered equipment
| Valid |
GB/T 37139-2018
|
PDF similar to GB/T 37139-2018
Basic data | Standard ID | GB/T 37139-2018 (GB/T37139-2018) | | Description (Translated English) | Requirements for EMC measurement methods for DC powered equipment | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L06 | | Classification of International Standard | 33.100 | | Word Count Estimation | 18,142 | | Date of Issue | 2018-12-28 | | Date of Implementation | 2019-07-01 | | Regulation (derived from) | National Standard Announcement No. 17 of 2018 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 37139-2018: Requirements for EMC measurement methods for DC powered equipment---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Requirements for EMC measurement methods for DC powered equipment
ICS 33.100
L06
National Standards of People's Republic of China
EMC measurement method requirements for DC power supply equipment
Published on.2018-12-28
2019-07-01 implementation
State market supervision and administration
China National Standardization Administration issued
Content
Foreword I
1 Scope 1
2 Normative references 1
3 Terms and definitions, abbreviations 2
4 Equipment rating 3
5 Measurement conditions 3
6 Product Documentation 4
7 Applicability 4
8 Launch and immunity requirements 4
9 Measurement uncertainty 4
10 Standard compliance for emission measurements 4
11 immunity test performance criterion 4
Reference 15
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed and managed by the National Radio Interference Standardization Technical Committee (SAC/TC79).
This standard was drafted. Shanghai Electric Apparatus Research Institute, Xi'an Teruide Intelligent Charging Technology Co., Ltd., China Electronic Technology Standardization
Institute, Shanghai Sanji Electronic Industry Co., Ltd., Shanghai Siemens Line Protection System Co., Ltd., Ministry of Industry and Information Technology
Institute, Shanghai Electric Apparatus Research Institute (Group) Co., Ltd.
The main drafters of this standard. Xing Lin, Ru Yonggang, Cui Qiang, Shi Beina, Chen Yu, Xiong Houyi, Zhu Wenli.
EMC measurement method requirements for DC power supply equipment
1 Scope
This standard specifies the electromagnetic compatibility (EMC) requirements for DC power supply equipment, including equipment grading, measurement conditions, product documentation, and
Requirements for usability, emission and immunity requirements, measurement uncertainty, standard compliance for emission measurements, and immunity test performance criteria.
This standard applies to DC power supply equipment that meets the following conditions.
a) a DC power port with the definition of 3.1.5;
b) The rated voltage does not exceed 1500VDC.
This standard applies if there is no relevant product or product class electromagnetic compatibility standard.
This standard specifies the test requirements and corresponding measurement/test methods for each port considered.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility
GB/T 6113.101-2016 Specification for equipment and methods of measurement of radio disturbance and immunity - Part 1-1. Radio disturbance and immunity
Disturbance measuring device measuring device
GB/T 6113.102-2008 - Radio disturbance and immunity measuring equipment and measuring methods - Part 1-2. Radio disturbance
And disturbance immunity measuring equipment auxiliary equipment conduction disturbance
GB/T 6113.104-2016 Radio disturbance and immunity measuring equipment and measuring methods - Part 1-4. Radio disturbances
Antenna and test site for radiation disturbance measurement of immunity measuring equipment
GB/T 6113.201-2017 Equipment and methods of measurement of radio disturbance and immunity - Part 2-1. Harassment and immunity test
Measurement method
GB/T 6113.203-2016 - Equipment and methods of measurement of radio disturbance and immunity - Part 2-3. Harassment and immunity test
Radiation disturbance measurement
GB/T 6113.402 Radio disturbance and immunity measuring equipment and methods of measurement - Part 4-2. Uncertainty, statistics
And limit modeling to measure the uncertainty of equipment and facilities
GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test
GB/T 17626.3 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test
GB/T 17626.4 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test
GB/T 17626.5 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test
GB/T 17626.6 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction
GB/T 17626.8 Electromagnetic compatibility test and measurement technology power frequency magnetic field immunity test
IEC TR61000-1-6 Electromagnetic compatibility - Part 1-6. Overview Guide to measurement uncertainty assessment (Electromagneticcom-
Patibility(EMC)-Part 1-6.General-Guidetotheassessmentofmeasurementuncertainty)
CISPR11 Limits and methods of measurement of radio frequency disturbance characteristics for industrial, scientific and medical equipment (Industrial,scientificand
medicalequipment-Radiofrequencydisturbancecharacteristics-Limitsandmethodsofmeasure-
Ment)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37139-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 37139-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 37139-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37139-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|