HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 34863-2017 English PDF

US$419.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 34863-2017: Technical specifications for water turbine in cooling tower
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34863-2017English419 Add to Cart 5 days [Need to translate] Technical specifications for water turbine in cooling tower Valid GB/T 34863-2017

PDF similar to GB/T 34863-2017


Standard similar to GB/T 34863-2017

GB/T 14478   GB/T 15468   GB/T 14478   GB/T 28572   

Basic data

Standard ID GB/T 34863-2017 (GB/T34863-2017)
Description (Translated English) Technical specifications for water turbine in cooling tower
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K55
Classification of International Standard 27.140
Word Count Estimation 21,210
Date of Issue 2017-11-01
Date of Implementation 2018-05-01
Regulation (derived from) National Standard Announcement 2017 No. 29
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34863-2017: Technical specifications for water turbine in cooling tower

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specifications for water turbine cooling tower ICS 27.140 K55 National Standards of People's Republic of China Cooling tower energy - saving turbine technical specifications Posted.2017-11-01 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 turbine model and its meaning 3 5 conditions of use 4 5.1 temperature 4 5.2 water quality 4 5.3 system can use energy 4 6 technical requirements 4 6.1 General requirements 4 6.2 Design parameters 4 6.3 Performance Guarantee 4 6.4 Turbine Structure 7 6.5 preservative 12 6.6 Noise 12 7 factory inspection and test 12 7.1 Inspection 12 7.2 Test 12 8 Installation 12 8.1 General Provisions 12 8.2 Connection to Inlet and Outlet Systems 12 8.3 Equipment Basis 13 8.4 Installation tolerances 13 8.5 turbine or reducer and fan connection 13 8.6 turbine and reducer connection 13 9 Automation Components and Monitoring 13 Site Acceptance and Commissioning 14 10.1 Preliminary Acceptance 14 10.2 72h trial run 14 11 spare parts and technical documents 14 11.1 spare parts 14 11.2 Technical Documents 14 12 Nameplate, packaging, shipping and storage 14 13 quality guarantee period 15 Appendix A (Informative) Calculation method of turbine related parameters 16

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed and managed by China Electrical Equipment Industry Association. This standard was drafted. Tianjin Electric Institute of Science and Technology Co., Ltd., Nanjing Star fly Cooling Equipment Co., Ltd., Jiangsu Hoi Ka Yu Energy-saving Technology Co., Ltd., Sinochem Cangzhou Cooling Technology Co., Ltd., Chongqing Jingye Hydropower Equipment Co., Ltd., Xi'an Nuopu Electrical Engineering Technology Co., Ltd., Fujian government and Yao Lung Hydraulic Turbine Co., Ltd., Anhui Hao Energy Technology Co., Ltd., Liaoning Winpower Energy Services Limited Division, China Tianchen Engineering Co., Ltd., China Energy Saving and Emission Reduction Co., Ltd. The main drafters of this standard. Song Guiling, Gu Ming, Shang Rui, An expensive people, Fang Yumin, Lan Bin, Liu Haibo, Zhang Linmao, Li Daying, Chen Yuanzheng, Solutions 煊, Wang Yue Feng, Huang Fei.

Introduction

In recent years, cooling tower turbine in smelting, petrochemical, chemical, coal chemical industry, light industry, pharmaceuticals, construction and other industries have been more and more widely application. Industrial cooling tower Francis turbine as energy-saving low-carbon technology has been the country's promotion. The principle is to use the cooling tower The surplus energy of the ring cooling water drives the turbine, replacing the motor driven fan by the turbine to save electric energy. Water cooling fan cooling tower energy-saving technology is Enterprises to achieve energy-saving emission reduction is an important means of building a resource-saving society to contribute. Turbine - fan has its unique linkage characteristics, the requirements of the circulating cooling water system of the turbine and conventional hydropower stations are very different. This standard for cooling tower turbine characteristics for the preparation of its design, manufacture, installation, inspection and so provide the basis. Cooling tower energy - saving turbine technical specifications

1 Scope

This standard specifies the cooling tower energy-saving turbine design, manufacture, installation, inspection and acceptance of the technical requirements. This standard applies to open mechanical ventilation cooling tower flow of single 0.056m3/s ~ 1.67m3/s (200m3/h ~ 6000m3/h), Built-in Francis or external shaft-extending tubular turbine connected directly to the fan or through a speed reduction mechanism. Stand-alone flow is less than 0.056m3/s (200m3/h) of the unit can refer to the implementation.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Hydropower plant hydraulic machinery and equipment GB/T 6967 engineering structure with medium and high strength stainless steel castings GB/T 7190.1 glass fiber reinforced plastic cooling tower Part 1. Small and medium glass fiber reinforced plastic cooling tower GB/T 7190.2 glass fiber reinforced plastic cooling tower Part 2. Large glass fiber reinforced plastic cooling tower GB/T 9439 gray cast iron GB/T 11352 for general engineering cast carbon steel parts GB/T 15468 turbine basic technical conditions GB/T 15613 (all parts) turbine, storage pump and pump turbine model acceptance test GB/T 50050 industrial circulating cooling water treatment design specifications GB 50236 field equipment, industrial pipe welding construction specifications Technical Specification for Mechanical Ventilation Cooling Tower GB/T HG/T 3132 L cooling tower fan JB/T 1270 turbine, turbine generator shaft forgings technical conditions JB/T 6752 small and medium turbine wheel static balance test procedures JB/T 8660 hydroelectric power unit packaging, transport and storage specifications JB/T 9099 cooling tower axial fan NB/T 42078 small turbocharger parts of the technical conditions SH/T 3022 petrochemical equipment and pipe coatings anti-corrosion design specifications

3 Terms and definitions

GB/T 2900.45, GB/T 15468, GB/T 50050 and GB/T 50392 as defined by the following terms and definitions apply to this file. 3.1 Turbine turbine Hydraulic machinery to convert water to mechanical energy.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 34863-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 34863-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 34863-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 34863-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.