US$169.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 2467-2008: Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods Status: Valid GB/T 2467: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 2467-2008 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods
| Valid |
GB/T 2467-2008
|
GB/T 2467.1-1996 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Pyrites and concentrate--Determination of lead content--Part 1: Flame atomic absorption spectrometric method
| Obsolete |
GB/T 2467.1-1996
|
GB 2467-1981 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Troilite and sulphur concentrates--Determination of lead content
| Obsolete |
GB 2467-1981
|
PDF similar to GB/T 2467-2008
Basic data Standard ID | GB/T 2467-2008 (GB/T2467-2008) | Description (Translated English) | Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | D51 | Classification of International Standard | 73.060.01 | Word Count Estimation | 7,773 | Date of Issue | 2008-05-14 | Date of Implementation | 2008-10-01 | Older Standard (superseded by this standard) | GB/T 2467.1-1996; GB/T 2467.3-1996 | Quoted Standard | GB/T 601; GB/T 6003.1; GB/T 6682; GB/T 9723 | Regulation (derived from) | National Standard Approval Announcement 2008 No.8 (Total No.121) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the determination by flame atomic absorption spectrometry and EDTA volumetric method Pyrites and concentrate lead content. This standard flame atomic absorption spectrometry applied to the lead content of 0. 01% to 1% of Pyrites and concentrate products. EDTA volumetric method applies Pyrites and concentrate products greater than 0. 1% lead content determination. |
GB/T 2467-2008: Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Pyrites and concentrate. Determination of lead content. Flame atomic absorption spectrometric and EDTA volumetric methods
ICS 73.060.01
D51
National Standards of People's Republic of China
Replacing GB/T 2467.1-1996, GB/T 2467.3-1996
Pyrites and concentrate - Determination of lead content
Flame atomic absorption spectrometric and EDTA volumetric method
Posted 2008-05-14
2008-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB/T 2467.1-1996 "Pyrites and concentrate - Determination of lead content - Part 1. Flame atomic absorption spectrometry
Law "and GB/T 2467.3-1996" Pyrites and concentrate - Determination of lead content - Part 3. EDTA volumetric method ", these two standard
It merged into a quasi-standard, divided into two methods.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard is under the jurisdiction of Chemical Industry Standardization Technical Committee chemical mine.
This standard was drafted. even in the blue sea and Design Institute.
The main drafters of this standard. the king of peace, Zhang Xiaomei.
This standard replaces the standards previously issued as follows.
--- GB/T 2467.1-1996;
--- GB 2467-1981, GB/T 2467.3-1996.
Pyrites and concentrate - Determination of lead content
Flame atomic absorption spectrometric and EDTA volumetric method
1 Scope
This standard specifies the flame atomic absorption spectrometric and EDTA volumetric method Pyrites and concentrate of lead content.
This standard flame atomic absorption spectrometry applied to the lead content of 0.01% to 1% Pyrites and concentrate products, EDTA content
Method for the determination of Pyrites and concentrate products lead content greater than 0.1%.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
Preparation of GB/T 601 chemical reagent standard titration solution
GB/T 6003.1 woven wire mesh test sieve (GB/T 6003.1-1997, eqv ISO 3310-1.1990)
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987)
GB/T 9723 Chemicals flame atomic absorption spectrometry General
3 Sample
The sample passes through 150μm test sieve (GB/T 6003.1), at 100 ℃ ~ 105 ℃ drying to constant weight, placed in a desiccator, cooled to
Room temperature.
4 General Provisions
The water of this standard shall comply with GB/T 6682 water in three specifications; reagents listed Unless otherwise specified, refer to analytical reagent.
5 Analysis
5.1 Flame Atomic Absorption Spectrometry
5.1.1 Method summary
Samples with hydrochloric acid - nitric acid is dissolved in dilute hydrochloric acid medium, using air - acetylene flame atomic absorption spectrometer at a wavelength of 283.3nm
The absorbance was measured to determine the lead content of working curve method.
5.1.2 Reagents and solutions
5.1.2.1 hydrochloric acid.
5.1.2.2 hydrochloric acid solution. 1 + 1.
5.1.2.3 nitrate.
5.1.2.4 Lead standard solution. 1.00mg/mL. Weigh 1.0000g purity metal lead in 250mL beaker, add 40mL of nitric acid
Solution (1 + 1), cover the surface of the pan, heat to dissolve completely cooled and transferred to 1000mL volumetric flask, dilute to the mark, shake. This solution
Liquid lead (Pb) amount of 1.00mg/mL.
5.1.2.5 Lead standard solution.200μg/mL. Draw 100.0mL lead standard solution (5.1.2.4) in 500mL flask with water
Dilute to the mark. This solution is lead (Pb) the amount of 200μg/mL.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 2467-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 2467-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 2467-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 2467-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 2467-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 2467-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|