US$1169.00 · In stock Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20840.5-2013: Instrument transformers -- Part 5: Additional requirements for capacitor voltage transformers Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 20840.5-2013 | English | 1169 |
Add to Cart
|
8 days [Need to translate]
|
Instrument transformers -- Part 5: Additional requirements for capacitor voltage transformers
| Valid |
GB/T 20840.5-2013
|
PDF similar to GB/T 20840.5-2013
Basic data | Standard ID | GB/T 20840.5-2013 (GB/T20840.5-2013) | | Description (Translated English) | Instrument transformers -- Part 5: Additional requirements for capacitor voltage transformers | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K41 | | Classification of International Standard | 29.180 | | Word Count Estimation | 53,549 | | Older Standard (superseded by this standard) | GB/T 4703-2007 | | Quoted Standard | GB 20840.1-2010; GB/T 156; GB 311.1; GB/T 2900.15; GB/T 2900.16; GB/T 2900.50; GB/T 2900.57; GB/T 5585.1; GB/T 7329; GB/T 7595; GB/T 19749 | | Adopted Standard | IEC 61869-5-2011, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2007 (Total No. 112); National Standards Bulletin 2013 No. 2 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to newly manufactured single-phase line -to-ground capacitor voltage transformer, its highest voltage for equipment Um �� 72. 5 kV, a frequency of 15 Hz ~ 100 Hz. Them as measurement, control and protection devices provide a low volta |
GB/T 20840.5-2013: Instrument transformers -- Part 5: Additional requirements for capacitor voltage transformers ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Instrument transformers Part 5. Additional requirements for capacitor voltage transformers
ICS 29.180
K41
National Standards of People's Republic of China
Replacing GB/T 4703-2007
Transformers - Part 5. Capacitor Voltage Transformer
Additional technical requirements
Part 5. Additionalrequirementsforcapacitorvoltagetransformers
(IEC 61869-5.2011, MOD)
Issued on. 2013-02-07
2013-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions
3.1 General definitions 2
3.2 Definitions for electrical insulation and voltage ratings of 6
3.4 concerning the definition of accuracy 7
3.5 For definitions of the other 7 ratings
7 3.7 Symbols and names
8 5 Rating
8 5.2 Highest voltage for equipment
5.3 Rated insulation level 8
5.4 rated frequency 10
5.5 rated output 10
Accuracy class 5.6 rated 11
5.501 Rated voltage standard value of 13
6 design and construction 14
6.1 Equipment required liquid with 14
6.7 the mechanical strength requirements 14
6.8 times a truncated end impact 14
6.9 Internal arc fault protection requirements 14
6.13 mark 14
6.501 short circuit withstand capability 19
6.502 Ferroresonance 19
6.503 Transient Response 20
6.504 Annex 21 requires carriers
7 Test 22
7.1 General 22
7.2 Type tests 25
7.3 Routine tests 32
36 7.4 Special tests
Appendix 5A (informative) of this section with IEC 61869-5. structural changes in 2011 compared to 37
Appendix 5B (informative) of this section with IEC 61869-5.2011 technical differences and their causes 39
Appendix 5C (normative) capacitor voltage transformer circuit diagram illustrating 43
High-frequency characteristics Appendix 5D (normative) capacitive voltage transformer 44
Appendix 5E (Informative Appendix) IEC 61869-5.2011 Electromagnetic unit insulation level, rated secondary voltage and for generating surplus
The rated voltage of the secondary winding voltage 45
Appendix 5F (Informative Appendix) under fault conditions capacitor voltage transformer another transient response 46
Foreword
GB 20840 "transformer" intends divided into the following sections.
--- Part 1. Common technical requirements;
--- Part 2. additional technical requirements current transformer;
--- Part 3. Supplementary technical requirements of electromagnetic voltage transformer;
--- Part 4. Combined Transformer additional technical requirements;
--- Part 5. additional technical requirements for capacitor voltage transformer;
--- Part 6. electronic transformer and low power independent of the sensor complement common technical requirements;
--- Part 7. Electronic voltage transformers supplementary technical requirements;
--- Part 8. Electronic current transformers additional technical requirements;
--- Part 9. Transformer digital interface;
--- Part 10. Supplementary independent current sensor technology low power requirements;
--- Part 11. Low-power complementary technologies independent voltage sensor requirements;
--- Part 12. Combined electronic transformer and complementary combination of technical requirements independent of the sensor;
--- Part 13. Independent merge cells.
This is Part 5 GB 20840's.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 4703-2007 "capacitor voltage transformers."
This section needs with GB 20840.1-2010 "transformers - Part 1. General technical requirements" supporting the use of. This section follows the
GB 20840.1 of the preparation of the structure, is a supplement corresponding provisions of GB 20840.1, modification or replacement. When the terms of GB 20840.1 in the present
Section not to mention timely, as long as reasonable, those terms would apply to this section. When specified in this section, "add", "modification" or "replacement"
When, it means that the relevant provisions of GB 20840.1 in this section is adapted accordingly.
For Zhang, bars, graphs, tables, notes and appendix in GB 20840.1-2010 based on additions, this section uses the following forms of ID.
--- Chapter, bar, graphs, tables, and note the number 501 from the beginning;
--- Appendix No. 5A, 5B and the like.
This section uses redrafted law revision using IEC 61869-5.2011 "Transformers Part 5. Capacitor voltage transformers supplementary
skills requirement".
This part of IEC 61869-5.2011, compared with more adjustment in the structure, are listed in Appendix 5A of this section with IEC 61869-5.
Chapter, article, figure, table number 2011 of the control list.
Technical differences exist compared to 2011, the terms of these differences have been involved through gaps in its outer margin. This part of IEC 61869-5
A single vertical line at position (|) have been identified in Appendix 5B are given a list of corresponding technical differences and their causes.
This section also made the following editorial changes.
--- Increasing the "Introduction";
--- Remove the IEC 61869-5.2011 5.3.5,7.2.3.3.1 and 7.3.8 of the section heading and the contents 7.2.3.3.1 Variable
7.2.3.3 for the contents of;
--- The IEC 61869-5.2011 is 5.3.501 and 7.3.1.504.1 (This section 7.3.2.504.1) public expression by text
Formula to formula expressed by the symbol, and symbols are explained for each formula;
--- The IEC 61869-5. 7.3.1.502 2011's (This section 7.3.2.502) and 7.3.2.2 (This section 7.3.3.2) with
Formula written expression changed in narrative form;
--- Increase the informative appendix 5E, the IEC 61869-5. Electromagnetic unit insulation level has not been adopted in 2011, rated secondary voltage
And for generating a residual voltage of the secondary winding voltage rating listed in the Appendix.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee transformers (SAC/TC222) centralized.
This section is drafted. Shenyang Transformer Research Institute Co., Ltd., State Grid Electric Power Research Institute, Tohoku Electric Power Research Institute shares
Parts Limited, Xi'an Electric Power Capacitor Co., Ltd., Guilin Power Capacitor Co., Ltd., TBEA Kangjia (Shenyang)
Transformer Co., Ltd., Shanghai MWB Transformer Co., Ltd., Nissin Electric (Wuxi) Co., Ltd., Dalian first transformer limited liability
Any company, Zhongshan City, Thailand Electric Co., Ltd., Dalian Northern Transformer Group Co., Ltd. Dalian transformer.
The main drafters of this section. cotton emperor, Zhang Zhong country, Wang Xiaoqi, Zhangjun Yang, Xiao Yaorong, Wangxiang Fang, Wang Zengwen, Liu Yufeng, Zhang Jun,
PAN Hong-mei, Sun Min, Yu Sha Chau, Xu Chao, Zhao Guoqing, Wang Yuan, Wang Yang.
Introduction
IEC /TC38 standard system has been realigned, before the upcoming IEC 60044 series of standards is now readjusted
IEC 61869 series of standards. In order to better use of international standards, the National Standardization Technical Committee transformers (SAC/TC222) The study
Decided to our current system of national standards Transformer also press IEC /TC38 new standard system be realigned before the upcoming
The individual transformers to national standards IEC 60044 series of standards by the corresponding relationship between IEC 61869 series of standards correspond to re
Develop, constitute a "common technical requirements" general part and each "Supplementary technical requirements" section dedicated supporting new Transformers series Country
standard.
New national standards for transformers intended to form the overall situation is as follows.
General part of the standard number and name
Special section
Standard
Dedicated part of the standard name
corresponding
Original Standard
GB 20840.1
General technical requirements
GB 20840.6 Electronic
Transformers and low power alone
Supplementary pass legislation sensor
Technical Requirements
Supplementary technical requirements GB 20840.2 current transformer
GB 1208
GB 16847
Complementary technology GB 20840.3 Electromagnetic Voltage Transformer requirements GB 1207
GB 20840.4 Combined Transformer supplementary technical requirements of GB 17201
GB/T 20840.5 additional technical requirements for capacitor voltage transformers GB/T 4703
GB 20840.7 additional technical requirements for electronic voltage transformer GB/T 20840.7
Supplementary technical requirements GB 20840.8 electronic current transformer
GB 20840.9 Transformer Digital Interface
Supplementary technical requirements GB 20840.10 low power independent current sensor
GB/T 20840.8
GB 20840.11 complementary technologies independent low power voltage sensor requirements GB/T 20840.7
GB 20840.12
Complement combination electronic transformer and combinations of independent sensors
Charge technical requirements
GB 20840.13 merge independent unit -
Transformers - Part 5. Capacitor Voltage Transformer
Additional technical requirements
1 Scope
This section GB 20840 applies to newly manufactured single-phase line-to-ground capacitor voltage transformer, its highest voltage for equipment Um≥72.5kV,
Frequency of 15Hz ~ 100Hz. They provide low-voltage measurement, control and protection devices.
Capacitor voltage transformers can be loaded wave accessory for the carrier frequency of 30kHz ~ 500kHz Power Line Carrier (PLC)
system.
The basic requirements for coupling capacitors and capacitive voltage divider according to GB/T 19749. Power Line Carrier (PLC) combined transport equipment requirements
According to GB/T 7329.
Measurement functions include measurements indicate that the measurement and billing.
501 Note. Appendix 5C shows the capacitor voltage transformer circuit diagram of an example of this section applies.
502 Note. If the user needs, the Um is 40.5kV capacitive voltage transformer can also be used in this section.
Note 503. high frequency characteristics of the capacitor voltage transformer in Appendix 5D.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. Who does not note date reference documents, the latest edition (including any amendments) applies to this document.
Chapter 2 GB 20840.1-2010 content with the following additions apply.
GB/T 156 standard voltage (GB/T 156-2007, IEC 60038.2002, IEC StandardVoltages, MOD)
GB 311.1 insulation coordination - Part 1. Definitions, principles and rules (GB 311.1-2012, IEC 60071-1.2006, MOD)
GB/T 2900.15 Electrotechnical terminology transformers, transformers, regulators and reactors (GB/T 2900.15-1997, IEC 60050
(421).1990; IEC 60050 (321). 1986, NEQ)
GB/T 2900.16 Electrotechnical terminology - Power capacitors (GB/T 2900.16-1996, IEC 60050 (436).1990, NEQ)
GB/T 2900.50 Electrotechnical terminology Generation, transmission and distribution of generic terms (GB/T 2900.50-2008, IEC 60050
(601). 1985, MOD)
GB/T 2900.57 Electrotechnical terminology Generation, transmission and distribution operations (GB/T 2900.57-2008, IEC 60050 (604).
1987, MOD)
GB/T 5585.1 electrician with copper, aluminum and its alloy bus - Part 1. Copper and copper alloy bus
GB/T 7329 Power Line Carrier binding device (GB/T 7329-2008, IEC 60481. 1974, NEQ)
Transformer oil quality GB/T 7595 running
GB/T 19749 coupling capacitors and capacitive voltage divider (GB/T 19749-2005, IEC 60358.1990, MOD)
GB 20840.1-2010 transformers - Part 1. General Requirements (IEC 61869-1.2007, MOD)
3 Terms and Definitions
GB 20840.1-2010, GB/T 2900.50 and GB/T 2900.57 and as defined in the following terms and definitions are appropriate additions
Used in this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20840.5-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 20840.5-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 20840.5-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20840.5-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|