US$214.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 12726.4-2013: Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams Status: Valid GB/T 12726.4: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 12726.4-2013 | English | 214 |
Add to Cart
|
3 days [Need to translate]
|
Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams
| Valid |
GB/T 12726.4-2013
|
| GB/T 12726.4-1995 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Radiation monitoring equipment for accident and post-accident conditions in nuclear power plants. Part 4: Process stream radiation monitor
| Obsolete |
GB/T 12726.4-1995
|
PDF similar to GB/T 12726.4-2013
Basic data | Standard ID | GB/T 12726.4-2013 (GB/T12726.4-2013) | | Description (Translated English) | Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F69 | | Classification of International Standard | 27.120.20 | | Word Count Estimation | 11,129 | | Older Standard (superseded by this standard) | GB/T 12726.4-1995 | | Quoted Standard | GB/T 2423.3-2006; GB/T 2423.4-2008; GB/T 12726.1-2013; IEC 60768 | | Adopted Standard | IEC 60951-4-2009, IDT | | Regulation (derived from) | National Standards Bulletin No. 25 of 2013 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the nuclear power plant after the accident and the process flow tube or next to radioactive devices generally require continuous monitoring, including the design principles and performance criteria. GB/T 12726. 1-2013 specifies the |
GB/T 12726.4-2013: Nuclear power plants -- Instrumentation important to safety -- Radiation monitoring for accident and post-accident conditions -- Part 4: Equipment for continuous in-line or on-line monitoring of radioactivity in process streams
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Nuclear power plants Instrumentation important to safety Radiation monitoring for accident and post-accident conditions Part 4. Equipment for continuous in-line or on-line monitoring of radioactivity in process streams
ICS 27.120.20
F69
National Standards of People's Republic of China
Replacing GB/T 12726.4-1995
Nuclear power plant safety important instrument for accident and post accident
Radiation monitoring Part 4. Process stream or canal
Equipment for continuously monitoring radioactivity adjacent tube
monitoringforaccidentandpost-accidentconditions-Part 4. Equipmentfor
(IEC 60951-4.2009, IDT)
Issued on. 2014-08-01 2013-12-17 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 1 Design Principles
4.1 Overview 1
4.2 Basic functional requirements 2
4.3 Measuring range 2
Mechanical properties of the detector within 4.4 2
5 Functional Test 3
5.1 Overview 3
5.2 Environmental Performance Test 3
Table 1 SAC/TC30/SC2/SC3 standard series Ⅳ
Supplementary Table 2 GB/T 12726.1-2013 test specified Additional Tests 5
Foreword
GB/T 12726 "after the nuclear power plant safety is important instruments accident and radiation monitoring" is divided into four parts.
--- Part 1. General requirements;
--- Part 2. gaseous effluents and ventilation equipment for continuous monitoring of radioactivity in the offline;
--- Part 3. High range area γ continuous monitoring equipment;
--- Part 4. Process flow tube or inner tube beside continuous radioactivity monitor.
This section GB/T Part of 412,726.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 12726.4-1995 "after a nuclear power plant accident and radiation monitoring equipment - Part 4. Process stream radiation monitoring
Tester ", compared with the GB/T 12726.4-1995 The main changes are as follows.
--- The process radiation monitor are divided into two basic types. next to the inner tube and the tube;
--- Deleted "5 test process stream," the description;
--- Increased material requirements;
--- The standard test condition has been modified;
--- Test requirements under standard test conditions made a comprehensive revision.
This section uses the translation method is equivalent to using IEC 60951-4. Radiation monitoring after 2009 "Instrumentation important to safety of nuclear power plants for accident and
Part 4. inner process tube or pipe beside continuous radioactivity monitoring equipment. "
For ease of use, this section made the following editorial changes.
--- Delete the original preface to the international standards;
--- With a decimal point instead of the original international standard as a decimal point ",". ",";
--- Will be in "2 Normative references" have been corresponding national standards with international standards to our standards;
--- Increase in IEC 60768 "normative references" on.
This part of the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) and focal points.
This section is drafted. Shanghai Nuclear Engineering Research and Design Institute.
The main drafters of this section. Chen Jing, Tang Zhichao.
GB/T 12726.4 in December 1995 the first release.
Introduction
a) standard technical background, major publications and organizations
This section focuses specifically on accident and after the accident radiation monitoring system in use.
The series of standards for user to a specific plant radiation monitoring system technical requirements, the manufacturer may be used in the series of standards
Determine the product characteristics required for the development of accident conditions of the system. Some detailed characteristics of the instrument, such as measuring range, in response to the energy and environmental conditions
Pieces shall be determined according to the specific application. In this case, the standard specifies only specific request, but does not claim itself will be described.
This section is important to safety after the accident radiation monitoring instruments in a standard series of standards. This series of standards consists of the following components.
--- GB/T 12726.1 important instrument for nuclear power plants accident and after the accident radiation monitoring - Part 1. General requirements
(GB/T 12726.1-2013, IEC 60951-1.2009, IDT)
--- GB/T 12726.2 important to safety of nuclear power plants after the accident and radiation monitoring instrumentation - Part 2. gaseous exhaust stream and pass
Wind Equipment for continuous monitoring of radioactivity in the offline (GB/T 12726.2-2013, IEC 60951-2.2009, IDT)
--- GB/T 12726.3 important to safety of nuclear power plants after the accident and radiation monitoring instruments - Part 3. High range area γ even
Continued monitoring device (GB/T 12726.3-2013, IEC 60951-3.2009, IDT)
--- GB/T 12726.4 important to safety of nuclear power plants after the accident and radiation monitoring instrumentation - Part 4. inner tube or pipe flow process
b) in the SAC/TC30/SC2/SC3 standard structure in the current standard status
GB/T 12726 series of standards is in the third level in SC2 standard hierarchy. GB/T 12726 series of standards for use in accident
And design and test conditions - radiation monitoring equipment to provide guidance after the accident. SC2 and SC3 other standards developed for use in normal operating
Radiation monitoring instruments under the conditions provided guidance. GB/T 7165 series of standards for the off-line continuous monitoring of radioactivity in gaseous effluents under normal conditions
It specifies the requirements for equipment. GB/T 10253 is a continuous off-line monitoring normal conditions of liquid radioactive effluents device specifies the requirements.
IEC 60768 for the continuous monitoring of the normal operation and anticipated operational occurrences within the process stream or a bypass pipe radioactive device specifies the requirements. most
After, ISO 2889 provides guidance for the gas and particle sampling. Table 1 shows the relationship between these different standards of radiation monitoring.
Table 1 SAC/TC30/SC2/SC3 standard series
Making organization ISO SC2 --- process and safety monitoring
After sampling circuit and a range of methods for accident and normal conditions and anticipated operational occurrences
SC3 --- radiation protection and
Effluent monitors
Zone sampling gases, particulates and
Iodine monitoring (offline)
ISO 2889
GB/T 12726.1 and
GB/T 12726.2
GB/T 7165 series of standards
Monitor with a liquid sample (from
line)
NA NA GB/T 10253
Without sampling (gaseous discharge
Flow, steam or liquid) process
Flow monitor (next to the pipe or tube)
Not applicable
GB/T 12726.1 and
GB/T 12726.4
IEC 60768 is not applicable
Regional monitoring does not apply
GB/T 12726.1 and
GB/T 12726.3
GB/T 14054
The central control system is not applicable IEC 61504 IEC 61559 series of standards
For details, see d SC2 series standard configuration).
c) The application of this series of standards and recommendations restrictions
Special attention in this series of standards does not establish additional functional requirements for the safety systems.
Relations d) SC2/SC3 standard describe the structure of the series and with other standards and other bodies (IAEA, ISO ) file
Top standard SC2 standard series is NB/T 20026. It is important for the implementation of nuclear power plant safety functions and instrumentation and control systems set up
Preparation of the provisions of the general requirements. NB/T 20026 standard series built SC2.
NB/T 20026 standard SC2 direct reference to the other, to the functional classification and grading systems, qualification, system isolation, Common Cause
Fault defense, computer-based software systems, hardware-based computer systems and control room design and other aspects. Should be considered in the second layer
Face direct reference to these standards and with the NB/T 20026 together as a reference document.
In the third level, not NB/T 20026 directly referenced SC2/SC3 standard relates to special equipment, technical methods, or specific living
Moving standard. In general, it refers to the second-level files These files can be its own reference.
Expanded technical report SC2/SC3 standard series, the fourth dimension is not part of the scope of standardization.
NB/T 20026 and basic safety publications have adopted similar representation formats.
Including the overall security architecture and life cycle system life cycle framework of IEC 61508 series of standards provide for the nuclear power plant sector
It describes the general requirements (IEC 61508.1, IEC 61508.2 and IEC 61508.4). Since the nuclear industry has to explain, in line with
NB/T 20026 will facilitate the IEC 61508 series of standards consistent with the requirements. In this framework, nuclear applications sector and IEC 60880
IEC 62138 correspond to IEC 61508.3.
NB/T 20026 quality assurance (QA) aspects of reference GB/T 19000-2008, GB/T 19001-2008 and HAF003
(Corresponding to IAEA50-C-QA, IAEA50-C-QA now IAEAGS-R-3-substituted).
SC2 and consistent implementation of the standard series detailing the principles and basic safety considerations for nuclear safety and nuclear safety regulations guide nuclear power plant,
Especially HAF102 requirements, the establishment of nuclear power plant design and safety guide HAD102/14 relates to the safety of nuclear power plants and important instrument
Control systems related to safety requirements. SC2 standard uses of nuclear safety regulations and nuclear safety guidelines consistent terminology and definitions.
Nuclear power plant safety important instrument for accident and post accident
Radiation monitoring Part 4. Process stream or canal
Equipment for continuously monitoring radioactivity adjacent tube
1 Scope
GB/T 12726 provisions of this section within the general after the nuclear power plant accident and the process flow tube or pipe beside continuous radioactivity monitoring equipment
Requirements, including design principles and performance criteria.
GB/T 12726.1-2013 specifies the technical characteristics of this type of equipment, test methods, radiation characteristics, electrical characteristics, mechanical properties and ring
General requirements for environmental characteristics and other aspects. Unless otherwise noted, these requirements apply to this section.
This section only applies to continuous measurement of the inner tube or pipe next to the detector is placed in the process stream (ie submerged therein) or close to work
Arts stream (ie field of vision directly over the pipe or tank) to measure radioactivity monitor. This section does not apply to the detector at a distance (sampling device
Office) representative fluid samples to monitor the measurement, which monitors belonging to GB/T 12726.2 range.
This section only applies after the accident and the monitor. Process flow in normal and anticipated operational occurrences during radiation monitoring equipment, see
IEC 60768.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test
(IEC 60068-2-78.2001, IDT)
GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h
12h cycle) (IEC 60068-2-30.2005, IDT)
Instrumentation important to safety after the accident and radiation monitoring - Part 1 GB/T 12726.1-2013 nuclear power plant. General requirements
(IEC 60951-1.2009, IDT)
IEC 60768 Nuclear power plant safety is important in the process stream pipe instrument during normal and anticipated operational occurrences or continuous monitoring of radioactivity adjacent tube
Measuring equipment (Nuclearpowerplants-Instrumentationimportanttosafety-Equipmentforcontinuousin-
lineoron-linemonitoringofradioactivityinprocessstreamsfornormalandincidentconditions)
3 Terms and Definitions
Terms and definitions GB/T 12726.1-2013 defined apply to this document.
4 Design Principles
4.1 Overview
Unless otherwise specified, shall meet all the requirements of GB/T 12726.1-2013 Chapter 4.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 12726.4-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 12726.4-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 12726.4-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 12726.4-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 12726.4-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 12726.4-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|