GB/T 11159-2010: Specifications for low air pressure test chambers
Status: Valid

GB/T 11159: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 11159-2010English209 Add to Cart 3 days [Need to translate] Specifications for low air pressure test chambers Valid GB/T 11159-2010
GB/T 11159-1989English279 Add to Cart 3 days [Need to translate] Specification for low air pressure test chambers Obsolete GB/T 11159-1989

PDF similar to GB/T 11159-2010


Standard similar to GB/T 11159-2010

GB/T 29252   GB/T 10589   GB/T 11158   GB/T 30099   GB/T 42580   

Basic data

Standard ID GB/T 11159-2010 (GB/T11159-2010)
Description (Translated English) Specifications for low air pressure test chambers
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N61
Classification of International Standard 19.040
Word Count Estimation 9,979
Date of Issue 2010-12-01
Date of Implementation 2011-05-01
Older Standard (superseded by this standard) GB/T 11159-1989
Quoted Standard GB 191-2000; GB 14048.1-2006; JB/T 9512-1999
Regulation (derived from) Announcement of Newly Approved National Standards No. 9, 2010 (No. 164 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the low pressure chamber and definitions of terms, conditions, technical requirements, test methods, inspection rules and signs, packaging and storage. This standard applies to electrical and electronic products and other products, parts and materials for low pressure test chamber.

GB/T 11159-2010: Specifications for low air pressure test chambers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specifications for low air pressure test chambers ICS 19.040 N61 National Standards of People's Republic of China Replacing GB/T 11159-1989 Low air pressure test chambers Issued on. 2010-12-01 2011-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Conditions 2 5 2 Technical Requirements 6 Test Method 3 7 inspection provisions 4 8 signs, packaging, storage 4

Foreword

The standard is "environmental testing equipment technology" series. The series of standards consists of the following standard components. --- GB/T 10586-2006 humid chamber technical conditions --- GB/T 10587-2006 salt spray test chambers --- GB/T 10588-2006 mildew test chambers --- GB/T 10589-2008 low temperature test chambers --- GB/T 10590-2006 high temperature/low air pressure test chambers --- GB/T 10591-2006 high temperature/low air pressure test chambers --- GB/T 10592-2008 high and low temperature test chambers --- GB/T 11158-2008 high temperature test chambers This standard replaces GB/T 11159-1989 "low pressure chamber and technical conditions." This standard and GB/T 11159-1989 main changes are as follows. a) increase the "Terms and Definitions" chapter; b) environmental conditions in expanding the scope of atmospheric pressure (see 4.1); c) increasing the chamber pressure 0.1kPa predetermined value a value (Table 1); d) increase the dielectric strength requirements (see 5.3.1). The standard proposed by China Machinery Industry Federation. This standard is under the jurisdiction of Machinery Industry Standardization Technical Committee laboratory instruments and equipment. This standard by the Chongqing Sida Test Equipment Co., Southern Jiangsu Wuxi Test Equipment Co., Ltd., Chengdu Sky Test Equipment Co., Ministry of Information Industry Institute of Electronics fifth, Hunan Institute of Metrology detection, mechanical Instrumentation Technology and Economy Institute is responsible for Drafted. The main drafters of this standard. Chen Yunsheng, Ni Yiming, Jin Xubin, Zousu Yang, Li Qing first, Feng Xiao L, Jinli Hui, Xiong Zhiming, Marin. This standard replaces the standards previously issued as follows. --- GB/T 11159-1989. Low air pressure test chambers

1 Scope

This standard specifies the low pressure chamber (hereinafter referred to as chamber) of the terms and definitions, conditions of use, technical requirements, test methods, inspection Rules and signs, packaging, storage. This standard applies to electrical and electronic products and other products, parts and materials for low-pressure test chamber.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 191-2000 Packaging - Pictorial signs (eqv ISO 780.1997) GB 14048.1-2006 Low-voltage switchgear and control equipment Part 1. General (modIEC 60947-1.2001) Determination of JB/T 9512-1999 climate chamber test equipment and sound power levels

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Chamber testchamber Wherein a portion can be sealed to meet the specified test conditions of housing and space. 3.2 Pressure setpoint airpressuresetpoint With chamber control means sets a desired pressure values. 3.3 Pressure nominal value achievednominalvalue According to the test method requires a predetermined pressure value or need a pre-determined pressure value. 3.4 The actual pressure achievedairpressure After stabilization, the pressure chamber work space. 3.5 Pressure stability airpressurestabilization The work space pressure to a pressure set value and maintained within the tolerance range. 3.6 Workspace workingspace Test chamber capable of maintaining a predetermined condition within the specified tolerance parts. 3.7 Air pressure changing rate airpressurerateofchange Workspace measured two to the transition rate between the air pressure set to kPa/min units. 3.8 Pressure deviation airpressurevariation After stabilization, at any time interval, the difference between the highest and lowest values \u200b\u200bof the nominal value of its air pressure and air pressure.