|
US$299.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 15581-2016: Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry Status: Valid GB 15581: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 15581-2016 | English | 299 |
Add to Cart
|
3 days [Need to translate]
|
Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry
| Valid |
GB 15581-2016
|
| GB 15581-1995 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry
| Obsolete |
GB 15581-1995
|
PDF similar to GB 15581-2016
Standard similar to GB 15581-2016 GB 17691 GB 15618 GB 14622
Basic data | Standard ID | GB 15581-2016 (GB15581-2016) | | Description (Translated English) | Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry | | Sector / Industry | National Standard | | Classification of Chinese Standard | Z64 | | Word Count Estimation | 15,149 | | Date of Issue | 2016-08-22 | | Date of Implementation | 2016-09-01 | | Older Standard (superseded by this standard) | GB 15581-1995 | | Quoted Standard | GB/T 6920; GB/T 7469; GB/T 11893; GB/T 11901; GB/T 11910; GB/T 11912; GB/T 16157; GB/T 16489; HJ 77.2; HJ 493; HJ 494; HJ 495; HJ 505; HJ 535; HJ 536; HJ 537; HJ 542; HJ 543; HJ 547; HJ 548; HJ 549; HJ 585; HJ 586; HJ 597; HJ 602; HJ 603; HJ 629; HJ 636; | | Regulation (derived from) | Ministry of Environmental Protection Notice No.56 of 2016; National Standard Notice No.2516 of 2016 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the emission limits, monitoring and monitoring requirements for water and air pollutants in caustic soda and polyvinyl chloride industrial enterprises, as well as the relevant provisions for the implementation and supervision of standards. This standard applies to the existing caustic soda, PVC industrial enterprises of water and air pollutant emissions management, as well as caustic soda, PVC industrial enterprises construction project environmental impact assessment, environmental protection facilities design, completion of environmental protection acceptance and put into operation Water Pollutants and Air Pollutant Emissions Management. This standard applies to pollutant discharge permitted by law. In addition to the implementation of this standard, should also be in accordance with the "People's Republic of China Water Pollution Control Law" "People's Republic of China Air Pollution Control Law", "People's Republic of China Ocean Environmental Protection Act " |
GB 15581-2016: Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Discharge standard of water pollutants for caustic alkali and polyvinyl chloride industry
ICS
Replacing GB 15581-95
Caustic soda, PVC industrial pollutant discharge standards
Emission standard of pollutants for caustic
And polyvinyl chloride industry
Ministry of Environmental Protection
State Administration of Quality Supervision, Inspection and Quarantine issued
2016-08-22 released
2016-09-01 implementation
National Standards of People's Republic of China
I directory
Preface ..ii
1 Scope of application
2 normative reference documents
3 terms and definitions
4 Pollutant Emission Control Requirements 4
5 Pollutant Monitoring Requirements
Implementation and supervision of standards
Appendix A (normative appendix) PCDD/Fs toxicity equivalent factor
Foreword
In order to implement the Environmental Protection Law of the People's Republic of China, the Law of the People's Republic of China on the Prevention and Control of Water Pollution,
And the State Air Pollution Prevention Law "," the People's Republic of China Marine Environmental Protection Law "and other laws and regulations, to protect the environment,
Pollution, promote caustic soda, PVC production process and pollution control technology progress, the development of this standard.
This standard is the "caustic soda, PVC industrial water pollutant discharge standards" (GB 15581-95) revision, the standard
The provisions of the caustic soda, PVC industrial enterprises water and air pollutant emission limits, monitoring and monitoring requirements. To promote regional economics
Economic and environmental development, promote the adjustment of economic structure and economic growth mode change, guide caustic soda, polyvinyl chloride industry
Production technology and pollution control technology development direction, this standard provides for water and air pollutants special emission limits.
This standard was first published in.1995, this time for the first revision.
The main contents of this revision.
- Increased air pollutant emission control requirements.
- Adjusted the water pollutant emission control project, tightening the water pollutant emission control requirements.
- Added special limits on water and air pollutants.
- Elimination of regulations for sewage management.
The concentration of pollutants in this standard is the mass concentration.
Caustic soda, PVC industrial enterprises emissions of stench pollutants, environmental noise and boiler emissions of air pollutants applicable to the corresponding
Of the national pollutant discharge standards, resulting in solid waste identification, treatment and disposal of national solid waste pollution control standards.
New caustic soda, PVC industrial enterprises since September 1,.2016 from the implementation of this standard, the existing enterprises since July 1,.2018
The implementation of this standard. Before July 1,.2018, the existing enterprises still implement the "caustic soda, PVC industrial water pollutant discharge standard
(GB 15581-95), "Integrated Emission Standard for Air Pollutants" (GB 16297-1996) and "Industrial Furnace Air Pollution
Discharge standards "(GB 9078-1996) in the relevant provisions.
This standard is the caustic soda, PVC industrial pollutant discharge control of the basic requirements. Local provincial people 's government on this standard
Unauthorized items can be formulated for local pollutant discharge standards; for this standard has been provided for the project,
The standard of local pollutant discharge standards. Environmental impact assessment documents or the requirements of the sewage permit than this or local standards
Strictly, should be approved in accordance with the environmental impact assessment or discharge permit documents.
This standard is organized by the Ministry of Environmental Protection Science and Technology Standards Division.
The main drafting of this standard. China Environmental Science Research Institute, Qingdao University of Science and Technology, China Chlor-Alkali Industry Association.
The environmental protection department of this standard approved on May 11,.2016.
This standard has been implemented since September 1,.2016.
This standard is explained by the Ministry of Environmental Protection.
1 caustic soda, PVC industrial pollutant discharge standards
1 Scope of application
This standard specifies the emission limits, monitoring and monitoring requirements for water and air pollutants in caustic soda and polyvinyl chloride industrial enterprises,
As well as the implementation of standards and supervision and other relevant provisions.
This standard applies to the existing caustic soda, PVC industrial enterprises of water and air pollutant emissions management, and caustic soda, polychlorination
Ethylene industrial enterprise construction project environmental impact assessment, environmental protection facilities design, completion of environmental protection acceptance and put into operation
Of water pollutants and air pollutant emissions management.
This standard applies to pollutant discharge permitted by law. Newly established sources of pollution and existing areas of special protection
The management of pollution sources, in addition to the implementation of this standard, should also be in accordance with the "People's Republic of China Water Pollution Control Law", "the Chinese people
The Republic of China on the Prevention and Control of Atmospheric Pollution, the Law of the People's Republic of China on the Protection of the Marine Environment, the Solid Waste of the People's Republic of China
Environmental Pollution Control Law of the People's Republic of China and other relevant laws, regulations and rules of the People's Republic of China
carried out.
Electrolytic potassium chloride production of potassium hydroxide in the process of water pollutants and air pollutant emissions management with reference to the implementation of this standard.
This standard does not apply to the pollutant discharge management in caustic caustic soda production.
The water pollutant emission control requirements stipulated in this standard apply to enterprises that directly or indirectly discharge water pollution outside their statutory borders
The behavior of the dye.
2 normative reference documents
The contents of this standard refer to the following documents or their terms. Those who do not specify the date of the reference file, the effective version of the appropriate
For this standard.
GB/T 6920 Determination of water quality pH - Glass electrode method
GB/T 7469 Determination of total mercury in water - Potassium permanganate - Potassium persulfate digestion method Dithizone spectrophotometric method
Water quality - Determination of total phosphorus - Ammonium molybdate spectrophotometric method GB/T
Water quality - Determination of suspended solids - Gravimetric method GB/T
GB/T 11910 Determination of water quality - Determination of butanedione oxime spectrophotometric method
Water quality - Determination of nickel - Flame atomic absorption spectrophotometric method GB/T
Determination of particulate matter and sampling method of gaseous pollutants in exhaust gas of fixed pollution sources GB/T 16157
Water quality - Determination of sulfide - Methylene blue spectrophotometric method GB/T 16489
HJ 77.2 Ambient air and exhaust dioxins Determination of isotope dilution High resolution gas chromatography - High resolution
Spectrum method
Technical specification for preservation and management of water quality samples
Technical Guidance for Water Quality Sampling
Design Technical Guidance for Water Quality Sampling Scheme
Determination of Biodegradation and Inoculation of DOD Biochemical Oxygen Demand (BOD5)
HJ 535 - Determination of ammonia nitrogen - Nessler 's reagent spectrophotometric method
HJ 536 Water quality - Determination of ammonia - Salicylic acid spectrophotometric method
Determination of ammonia nitrogen in water - Distillation - neutralization titration method
2HJ 542 Ambient air - Determination of mercury - Mercapto cotton enrichment - cold atomic fluorescence spectrophotometry (provisional)
HJ 543 Fixed sources of waste - Determination of mercury - Cold atomic absorption spectrophotometric method (provisional)
HJ 547 Fixed source of waste gas Determination of chlorine gas Iodometric method (provisional)
HJ 548 Fixed source of waste gas - Determination of hydrogen chloride - Silver nitrate volumetric method
HJ 549 Determination of ambient air and waste gas - Determination of hydrogen chloride - Ion chromatography
Determination of free chlorine and total chlorine in water - Determination of N, N - diethyl - 1,4 - phenylenediamine titration
HJ 586 Water quality Determination of free chlorine and total chlorine N, N-diethyl-1,4-phenylenediamine spectrophotometric method
HJ 597 Water quality - Determination of total mercury - Cold atomic absorption spectrophotometric method
Determination of barium in water - Graphite furnace atomic absorption spectrophotometric method
Determination of barium in water - Flame atomic absorption spectrophotometric method
HJ 629 Fixed sources - Determination of waste gas - Determination of sulfur dioxide - Non - dispersive infrared absorption method
HJ 636 Water quality - Determination of total nitrogen - Alkaline persulfate digestion - Ultraviolet spectrophotometric method
HJ 637 Water quality - Determination of petroleum and animal and vegetable oils - Infrared spectrophotometric method
HJ 639 Water quality - Determination of volatile organic compounds - Purge and trap - gas chromatography - mass spectrometry
HJ 644 Ambient air - Determination of volatile organic compounds Adsorption tube sampling - Thermal desorption/Gas chromatography - mass spectrometry
HJ 645 Ambient air - Determination of volatile halogenated hydrocarbons - Activated carbon adsorption - Carbon disulfide desorption/gas chromatography
HJ 665 - Determination of ammonia nitrogen - Continuous flow - Salicylic acid spectrophotometric method
Determination of ammonia nitrogen in water - Flow injection - salicylic acid spectrophotometric method
Determination of total nitrogen content - Continuous flow - Naphthylenediamine hydrochloride spectrophotometric method
Determination of total nitrogen content - Flow injection - Naphthylenediamine hydrochloride spectrophotometric method
HJ 670 Water quality - Determination of phosphate and total phosphorus - Continuous flow - Ammonium molybdate spectrophotometric method
Determination of total phosphorus in water - Flow injection - Ammonium molybdate spectrophotometric method
HJ 675 Fixed sources - Determination of exhaust nitrogen oxides - Acid - base titration method
HJ 692 Fixed sources - Determination of waste nitrogen oxides - Non - dispersive infrared absorption method
Determination of nitrogen oxides for fixed sources of pollution - Determination of potential oxides
Determination of Mercury, Arsenic, Selenium, Bismuth and Antimony in Water by HJ 694 - Atomic Fluorescence Spectrometry
Determination of 65 kinds of elements in water quality of HJ 700 - Inductively coupled plasma mass spectrometry
HJ 776 Water quality - Determination of 32 elements - Inductively coupled plasma - atomic emission spectrometry
HJ 732 Sampling Air Bag Method for Volatile Organic Compounds of Fixed Pollutants
HJ 759 Ambient air - Determination of volatile organic compounds - Tank sampling/gas chromatography - mass spectrometry
Determination of Volatile Organic Compounds in Water Quality by Headspace/Gas Chromatography - Mass Spectrometry
HJ/T 27 Determination of hydrogen chloride in fixed sources - Mercury thiocyanate spectrophotometric method
HJ/T 30 Determination of chlorine in exhaust gas from stationary sources - Methyl orange spectrophotometric method
HJ/T 34 Determination of vinyl chloride in the exhaust gas of fixed sources - Gas chromatographic method
Determination of non - methane total hydrocarbons in exhaust gas from fixed sources of pollution - Gas chromatographic method
HJ/T 42 Determination of nitrogen oxides in the exhaust gas of fixed sources - Ultraviolet spectrophotometric method
HJ/T 43 Determination of nitrogen oxides in fixed exhaust gases - Naphthylenediamine hydrochloride spectrophotometric method
Technical Guidelines for Unorganized Emissions Monitoring of Air Pollutants
3HJ/T 56 Determination of sulfur dioxide in exhaust gas from stationary sources - Iodometric method
Determination of Sulfur Dioxide in Fixed Air Pollutants by HJ/T 57
HJ/T 60 Determination of water quality sulfide iodometric method
HQ/T 70 Determination of chemical oxygen demand for high chlorine wastewater - Chlorine calibration method
Technical specification for continuous monitoring of flue gas emissions from fixed pollution sources of HJ/T 75 (for trial implementation)
HJ/T 76 fixed pollution source flue gas emissions continuous monitoring system technical requirements and testing methods (Trial)
Technical specification for surface water and wastewater monitoring
Determination of ammonia nitrogen in water. Determination of ammonia nitrogen by gas phase molecular absorption spectrometry
Water quality - Determination of total nitrogen - Gas phase molecular absorption spectrometric method
HJ/T.200 - Determination of water quality Sulfide - Gas phase molecular absorption spectrometric method
HJ/T 373 fixed pollution source monitoring quality assurance and quality control technical specifications (Trial)
Technical specification for HJ/T 397 fixed source exhaust gas monitoring
"Administrative Measures for Automatic Monitoring of Pollution Sources" (State Environmental Protection Administration Decree No. 28)
"Environmental Monitoring Management Measures" (State Environmental Protection Administration Decree No. 39)
3 terms and definitions
The following terms and definitions apply to this standard.
3.1 caustic soda industry caustic acid industry
Sodium chloride as raw material using ion exchange membrane electrolysis production of liquid alkali, caustic soda and chlorine hydrogen treatment industry.
PVC polyvinyl chloride industry
The use of acetylene and ethylene oxychloride production of PVC industry. This standard refers to the use of acetylene production of PVC or
Production Process of Polyvinyl Chloride from Vinyl Chloride Monomer in Ethylene Oxychlorination Process.
3.3 acetylene method
Production of Polyvinyl Chloride from Acetylene and Hydrogen Chloride as Raw Materials. This standard mainly refers to calcium carbide method.
O ethylene oxychlorination process
Production of Polyvinyl Chloride from Chlorine, Ethylene and Oxygen as Raw Materials.
3.5 Features Production process and installation
Processes and devices for the production of caustic soda, polyvinyl chloride, and contaminant treatment processes and devices associated with these processes.
3.6 existing enterprises existing facility
The implementation of this standard has been completed before the production or environmental impact assessment documents have been approved by the caustic soda, PVC industrial enterprises
Industry or production facilities.
3.7 new enterprise new facility
The environmental impact assessment documents from the date of implementation of this standard through the approval of the new, alteration and expansion of caustic soda, polyvinyl chloride
Production facilities construction projects.
3.8 public sewage treatment system public wastewater treatment system
Collect waste water through pipelines, etc. Provide waste water treatment services for two or more sewage units and drain
To the relevant emission standards required by enterprises or institutions, including the size and type of urban sewage treatment plants, areas (including the
Industrial parks, development zones, industrial clusters, etc.) wastewater treatment plants, the degree of wastewater treatment should reach two or two to
on.
43.9 direct discharge direct discharge
Discharge units directly to the environmental water discharge of water pollutants.
Indirect discharge
Discharge of sewage to the public sewage treatment system of water pollutant behavior.
3.11 displacement effluent volume
Caustic soda, PVC production facilities or the amount of wastewater discharged by enterprises outside the legal boundary, including direct production
(Such as factory sewage, cooling wastewater, etc.).
3.12 unit product baseline displacement benchmark effluent volume per unit product
The upper limit of the amount of wastewater discharged from the production unit for the purpose of approving the concentration of water pollutants.
3.13 Emissions of atmospheric pollutants per unit product air pollutant emission amount per unit product
Production unit PVC product upper limit of air pollutant emissions (kg/t).
3.14 standard state standard condition
The temperature is 273.15K, the pressure is 101325Pa when the state. The limits of atmospheric pollutant emission limits specified in this standard
Are based on the standard state of dry gas as a benchmark.
Oxygen content
After the fuel is burned, the excess free oxygen contained in the flue gas is usually expressed as a percentage of dry basis volume.
3.16 enterprise boundary
Caustic soda, the legal boundary of PVC industrial enterprises. If there is no boundary, it refers to the actual boundary.
3.17 dioxin dioxins
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collectively.
3.18 toxic equivalence factor (TEF)
The ratio of dioxins to the affinity of 2,3,7,8-tetrachlorodibenzo-p-dioxin to Ah receptors.
3.19 toxic equivalence quantity (TEQ)
The concentration of dioxins is equivalent to the equivalent concentration of 2,3,7,8-tetrachlorodibenzo-p-dioxin,
The toxicity equivalent concentration is the product of the measured concentration and the toxicity equivalent factor of the isomer.
4 Pollutant Emission Control Requirements
4.1 Water Pollutant Emission Control Requirements
4.1.1 Since September 1,.2016, the new enterprises have implemented the water pollutant discharge limits set out in Table 1.
4.1.2 Prior to 1 July.2018, existing enterprises should continue to implement the current standards. Since July 1,.2018, the existing
The enterprise implements the water pollutant discharge limits specified in Table 1.
Table 1 Water pollutant emission limits
Unit. mg/L (except pH)
No. Contaminant Project Control Pollution Source
Emission limits
Direct discharge of the monitoring position
1 pH caustic soda enterprises, PVC enterprises 6 ~ 9 6 ~ 9 enterprise wastewater
Total Discharge Port 2 Chemical Oxygen Demand Caustic Soda Enterprise, Polyvinyl Chloride Enterprise 60 250
5 (CODCr)
Five days of biochemical oxygen
Volume (BOD5)
Polyvinyl Chloride Enterprise
4 suspended matter caustic soda enterprises, PVC enterprises 30 70
5 oil caustic soda enterprises, PVC enterprises 3 10
6 ammonia nitrogen caustic soda enterprises, PVC enterprises 15 40
7 total nitrogen caustic soda enterprises, PVC enterprises 20 50
8 Calcium Phosphate Enterprise, PVC Enterprise 1.0 5.0
9 Sulfide Acetylene Process Polyvinyl Chloride Enterprise 0.5 0.5
Total barium caustic soda business 5 5
11 active chlorine caustic soda enterprises 0.5
Workshop or production
Device discharge port
12 Vinyl Chloride Polyvinyl Chloride Enterprise
Total Mercury Acetylene Process PVC Company
Total nickel caustic soda business
Unit product base displacement
(M3/t product)
Caustic Soda Enterprise 1.0 Displacement Metering Location
And pollutant discharge monitoring
Control the same position
Acetylene Polyvinyl Chloride Enterprise 5.0
Ethylene Oxychlorination Process PVC Enterprise 2.0
4.1.3 According to the requirements of environmental protection work, the density of land development has been higher, the environmental carrying capacity began to weaken, or water
Environmental capacity is small, the ecological environment is fragile, prone to serious water pollution problems and the need to take special protective measures to the ground
Area, should strictly control the company's pollution emissions behavior in the above-mentioned areas of enterprises to implement the special discharge of water pollutants as specified in Table 2
Limit.
The geographical scope of the special discharge limit for the implementation of water pollutants shall be determined by the competent department of environmental protection administration or the provincial level of the State Council
Civil government regulations.
Table 2 Specific limits for water pollutants
Unit. mg/L (except pH)
Pollutant project controls pollution sources
Emission limits
Direct discharge of the monitoring position
1 pH caustic soda enterprises, PVC enterprises 6 ~ 9 6 ~ 9
Enterprise wastewater
Total discharge
Cod
(CODCr)
Caustic soda enterprises, polyvinyl chloride enterprises 40 60
Five days of biochemical oxygen
Volume (BOD5)
Polyvinyl Chloride Enterprise
4 suspended matter caustic soda enterprises, PVC enterprises 20 30
5 oil caustic soda enterprises, PVC enterprises 1 3
6 ammonia nitrogen caustic soda enterprises, PVC enterprises 8 15
67 total nitrogen caustic soda enterprises, PVC enterprises 10 20
8 Sulfur Phosphate Enterprise, Polyvinyl Chloride Enterprise 0.5 1.0
9 Sulfide Acetylene Process PVC Company 0.2 0.2
Total barium caustic soda business 5 5
11 active chlorine caustic soda enterprises 0.5
Workshop or production
Device discharge port
12 Vinyl Chloride Polyvinyl Chloride Enterprise
Total Mercury Acetylene Process PVC Company
Total nickel caustic soda business
Unit product base displacement
(M3/t product)
Caustic Soda Enterprise 1.0 Displacement Metering Location
And pollutant discharge monitoring
Control the same position
Acetylene Polyvinyl Chloride Enterprise 5.0
Ethylene Oxychlorination Process PVC ...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 15581-2016_English be delivered?Answer: Upon your order, we will start to translate GB 15581-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 15581-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB 15581-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 15581-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 15581-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|