HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GA 943-2011 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 943-2011English759 Add to Cart 4 days [Need to translate] Technical requirements for the overhead psychological training facility for fireman Obsolete GA 943-2011

PDF similar to GA 943-2011


Standard similar to GA 943-2011

GB 4066   GA 578   GB 5135.3   GA/T 998   

Basic data

Standard ID GA 943-2011 (GA943-2011)
Description (Translated English) Technical requirements for the overhead psychological training facility for fireman
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C83
Classification of International Standard 13.220.10
Word Count Estimation 18,163
Date of Issue 2011-06-13
Date of Implementation 2011-07-01
Quoted Standard GB 4053.3; GB 8408-2008; GB 8918; GB 19079.4; GB 50007-2002; GB 50205-2001; GA 494; GA/T 623
Regulation (derived from) Chemical plant fire accident handling training facilities, technical requirements and other three industry standards; industry standard filing notice No. 4 in 2012 (total 148)
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the terms and definitions, technical requirements and acceptance rules for firefighters upper-air psychological training facilities. This standard is applicable to the design, construction and acceptance of high-altitude psychological training facilities for firefighters.

GA 943-2011: Technical requirements for the overhead psychological training facility for fireman


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical requirements for the overhead psychological training facility for fireman ICS 13.220.10 C83 People's Republic of China Public Security Industry Standards Firefighters altitude mental training facilities technical requirements Issued on. 2011-06-13 2011-07-01 implementation People's Republic of China Ministry of Public Security

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 2 Technical Requirements 5 acceptance 12 Appendix A (normative) aerial firefighters psychological training facilities completion acceptance report Table 14

Foreword

The contents of this standard 4.1,4.3 are mandatory, the rest are recommended. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee fire fighting and rescue Technical Committee (SAC/TC113/SC10) centralized. This standard is drafted by. Chinese People's Armed Police Force Academy. Participated in the drafting of this standard. sea Beijing Electronics Co., Ltd. is close. The main drafters of this standard. Li Jinxing, Zhangzi Hai, Zhang Xiaoli, Huamin, Wuyi Juan, Deng Li Yan, Guo Yan, Liu Zeyi, Zhao Shuai, Bob bits. This standard is the first release. Firefighters altitude mental training facilities technical requirements

1 Scope

This standard specifies the terms and definitions Psychological firefighters altitude training facilities, technical requirements and acceptance rules. This standard applies to firefighters altitude psychological training facility design, construction and acceptance.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4053.3 fixed ladders and platforms - Safety requirements - Part 3. Industrial guardrails and steel platform GB 8408-2008 Safety specifications rides GB 8918 important uses rope GB 19079.4 sports venues open conditions and technical requirements - Part 4. Rock Climbing place GB 50007-2002 Code for design of building foundation Steel Engineering Construction Quality Acceptance GB 50205-2001 GA 494 fire with fall protection equipment GA/T 623 Fire Training Base training facility construction standards

3 Terms and Definitions

GA/T 623 as well as to determine the following terms and definitions apply to this document. 3.1 Body frame mainframe Mental training firefighters to withstand high altitude of the metal frame generated by a variety of loads, including vertical columns and connected to the top of the relevant legislation Based beams and columns and other column. 3.2 Structural beam crossbeam Horizontally disposed between related columns, steel structures to facilitate the construction of various training systems devices. 3.3 Structure column uprightpost Vertically in the relevant structures and underground foundation beams between, steel structures to facilitate various training systems configured devices. 3.4 Aerial trapeze overheadtrapeze Suspended in the beam firefighters altitude training facilities Mental body frame to withstand the weight of the firefighters jump when gripping and impact loads Metal bars and ancillary equipment. 3.5 Bridge height overheadbrokenbridge It ends fixed to the body post for training firefighters intermediate altitude capability across disconnected Itabashi.