HOME   Cart(1)   Quotation   About-Us Tax PDFs Standard-List
Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 189760 (9 Dec 2023)

GB/T 532-2008 (GB/T532-2008)

Chinese standards (related to): 'GB/T 532-2008'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusGoogle Book
GB/T 532-2008English80 Add to Cart 0-9 seconds. Auto delivery. Rubber, vulcanized or thermoplastic -- Determination of adhesion to textile fabric GB/T 532-2008 Valid GBT 532-2008
GB/T 532-1997English279 Add to Cart 3 days Rubber, vulcanized or thermoplastic--Determination of adhesion to textile fabric GB/T 532-1997 Obsolete GBT 532-1997
GB/T 532-1989EnglishRFQ ASK 3 days Rubber vulcanized--Determination of adhesion to textile fabric GB/T 532-1989 Obsolete GBT 532-1989


   
BASIC DATA
Standard ID GB/T 532-2008 (GB/T532-2008)
Description (Translated English) Rubber, vulcanized or thermoplastic. Determination of adhesion to textile fabric
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G40
Classification of International Standard 83.060
Word Count Estimation 7,720
Date of Issue 2008-06-04
Date of Implementation 2008-12-01
Older Standard (superseded by this standard) GB/T 532-1997
Quoted Standard GB/T 2941; GB/T 12833; ISO 5893-2002
Adopted Standard ISO 36-2005, IDT
Drafting Organization Beijing Research and Design Institute of Rubber Industry
Administrative Organization National Standard Committee rubber rubber physical and chemical test methods Technical Committee
Regulation (derived from) National Standard Approval Announcement 2008 No.9 (Total No.122)
Proposing organization China Petroleum and Chemical Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies test methods for measuring the force required to separate the interface between the rubber or thermoplastic rubber and fabric layer bonded using the strip method. This standard applies to the adhesive layer of the sample or the inner diameter of approximately 50 mm above the plane of the cylindrical sample. This standard does not apply to inter-layer surface contains a sharp bend in the angle cut or other specimen has serious irregularities in the sample. This standard does not apply to coated fabrics, coated fabrics can be tested for in accordance with the provisions of HG/T 3052 's, does not apply to textile conveyor belts, conveyor belts for fabric can be tested in accordance with the provisions of GB/T 6759 's.


GB/T 532-2008: PDF in English (GBT 532-2008)
GB/T 532-2008
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 83.060
G 40
GB/T 532-2008 / ISO 36:2005
Replacing GB/T 532-1997
Rubber, Vulcanized or Thermoplastic
– Determination of Adhesion to Textile Fabric
(ISO 36:2005, IDT)
ISSUED ON: JUNE 04, 2008
IMPLEMENTED ON: DECEMBER 01, 2008
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms and Definitions ... 6
4 Principle ... 6
5 Instrument ... 6
6 Specimen ... 7
7 Number of Specimens ... 7
8 Time interval between Vulcanization and Test ... 7
9 Environmental Conditioning and Test Temperature of the Specimen ... 8
10 Test Procedures ... 8
11 Test Results ... 9
12 Test Report ... 9
Bibliography ... 10
Rubber, Vulcanized or Thermoplastic
– Determination of Adhesion to Textile Fabric
WARNING - Persons using this Standard shall have practical experience working in
formal laboratory. This Standard does not point out all possible safety issues, the user is
responsible for taking appropriate safety and health measures and ensuring compliance
with the conditions stipulated by relevant national regulations.
1 Scope
This Standard specifies a test method for the determination of the force required to separate the
adhesive interface BETWEEN rubber or thermoplastic rubber AND fabric layers or between
fabric and fabric layers by peeling method.
This Standard applies to samples with an approximately flat adhesive layer or cylindrical
samples with an inner diameter of more than 50mm.
This Standard does not apply to specimens whose interlaminar surfaces contain sharp bend
angles or other severe irregularities when the specimen is cut.
This Standard does not apply to coated fabrics, which can be tested in accordance with the
provisions of HG/T 3052. It also does not apply to fabric conveyor belts, which can be tested
in accordance with the provisions of GB/T 6759.
2 Normative References
The provisions in following documents become the provisions of this Standard through
reference in this Standard. For dated references, the subsequent amendments (excluding
corrigendum) or revisions do not apply to this Standard, however, parties who reach an
agreement based on this Standard are encouraged to study if the latest versions of these
documents are applicable. For undated references, the latest edition of the referenced document
applies.
GB/T 2941 Rubber - General Procedures for Preparing and Conditioning Test Pieces for
Physical Test Methods (GB/T 2941-2006, ISO 23529:2004, IDT)
GB/T 12833 Rubber and Plastics - Analysis of Multipeak Traces Obtained in
Determinations of Tear Strength and Adhesion Strength (GB/T 12833-2006, ISO
6133:1998, IDT)
ISO 5893:2002 Rubber and Plastics Test Equipment – Tensile, Flexural and Compression
Types (Constant Rate of Traverse) – Specification
3 Terms and Definitions
For the purposes of this Standard, the following terms and definitions apply.
3.1 Adhesion strength
The force required to separate a specimen of unit width to separate two adhesion interfaces.
NOTE: Separation may occur at non-adhesion interfaces. If it occurs inside a material to be adhered, it
belongs to the destruction of the material to be adhered and cannot indicate its adhesion strength. In this
case, the adhesion strength is greater than the strength of the weakest material.
4 Principle
Under specified conditions, determine the force required to separate the adhesion interface
between vulcanized rubber or thermoplastic rubber and fabric layers, or between fabrics
adhered with rubber and fabric layers. The shape of the specimen is a standard flat strip one.
5 Instrument
5.1 Testing machine
The testing machine shall be electric and fitted with a suitable dynamometer, preferably a non-
inertial dynamometer (e.g., electronic or optical). During the test, the mobile gripper shall keep
moving at a substantially constant speed and be equipped with an automatic recorder or a
computer with graphing software available for data acquisition and processing.
The testing machine shall comply with the provisions of ISO 5893; and the accuracy of the
elongation dynamometer shall meet the requirements of Class-2 in ISO 5893:2002. And the
moving speed of the gripper is 50mm/min±5mm/min.
The testing machine shall be equipped with grippers to hold the specimen and shall not slip
during the test.
5.2 Automatic chart recorder
The recorder has enough range for easy analysis of peeling curve graphs. Or a computer with
graphics software, the computer’s automatic recording graphics software shall comply with the
provisions of data processing procedures in GB/T 12833.
weeks. In order to make the test results comparable, the comparative test shall be carried
out within the same time interval as possible.
c) For product tests, where possible, the time interval between test and vulcanization shall
not exceed 3 months. In other cases, the test shall be carried out within two months from
the date of receipt by the purchaser.
9 Environmental Conditioning and Test Temperature of the
Specimen
The environmental conditioning of all samples shall comply with the provisions of GB/T 2941.
If the sample preparation includes grinding, the time interval between grinding and test shall
be a minimum of 16h and a maximum of 72h.
For the test at the standard laboratory temperature (see GB/T 2941), the test piece cut from the
environmental conditioning specimen can be tested immediately at the standard temperature if
no further preparation is required. For further preparation, it shall be adjusted at standard
temperature for a minimum of 3h.
For the test at non-standard temperature, according to the provisions of GB/T 2941, adjust
enough time at the specified temperature to ensure that the specimen reaches the equilibrium
state.
10 Test Procedures
Take the specimen specified in 6.1; peel off a layer of fabric or a layer of glue with a length of
about 50mm by hand. For initial separation, a scalpel or similar tool can be used, and fix both
ends of the peeled specimen on the gripper of the testing machine (5.1); and adjust the specimen
so that the tensile force is evenly distributed and the specimen is not twisted during the test.
The main body of the specimen is clamped on the fixed gripper, and the peeled layer is placed
in the moving gripper, so that the peeling angle is about 180°. What is important here is to
ensure that the axes of the flat-strip specimen in the gripper are in the same plane.
Start the testing machine and carry out continuous peeling; while recording with a chart
recorder or computer (see 5.2) the force required to peel at least a length of 100 mm. The
moving speed of the gripper shall be 50mm/min±5mm/min.
Check the specimen for peeling or damage.
......