HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (8 Jun 2025)

English GB/T 39959-2021 PDF

Search result: GB/T 39959-2021
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 39959-2021English494 Add to Cart 4 days [Need to translate] Liquid pumps and pump units - Noise test code - Grades 2 and 3 of accuracy Valid GB/T 39959-2021


BASIC DATA
Standard ID GB/T 39959-2021 (GB/T39959-2021)
Description (Translated English)
Sector / Industry National Standard (Recommended)


GB/T 39959-2021 Liquid pumps and pump units - Noise test code - Grades 2 and 3 of accuracy ICS 23.080 J71 National Standards of People's Republic of China Noise test methods for liquid pumps and pump units Level 2 and Level 3 (ISO 20361.2019, IDT) Released on 2021-03-09 2021-10-01 implementation State Administration of Market Supervision and Administration Issued by the National Standardization Management Committee Table of contents Foreword Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Classification and configuration of pumps 2 5 Determination of sound power level 2 6 Measurement of emission sound pressure level 8 7 Uncertainty 9 8 Installation and equipment conditions 9 9 Working conditions for noise measurement 10 10 Information Recording and Reporting 11 11 Labeling and verification of noise emission values 11 Appendix A (Normative Appendix) Pump --- Measuring Surface 12 Appendix B (Normative appendix) Pump unit---Sound pressure level measurement of pumps of different types and sizes. Surface microphone position 13 Appendix C (informative appendix) Example of dual-value noise labeling 19 Reference 20 Preface This standard was drafted in accordance with the rules given in GB/T 1.1-2009. The translation method used in this standard is equivalent to ISO 20361.2019 "Liquid Pumps and Pump Unit Noise Test Methods Level 2 and Level 3". The Chinese documents that have a consistent correspondence relationship with the normatively cited international documents in this standard are as follows. ---GB/T 14574-2000 Labeling and verification of noise emission values of acoustic machinery and equipment (eqvISO 4871.1996) For ease of use, this standard has made the following editorial changes. --- Deleted the URL guide in Chapter 3 of ISO 20361.2019; --- Change "h" in Figure 6 to "h1". This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Pump Standardization Technical Committee (SAC/TC211). Drafting organizations of this standard. Hefei Huasheng Pump & Valve Co., Ltd., Guangdong Kenfola Pump Industry Co., Ltd., Jialite Ebara Pump Industry Co., Ltd. Co., Ltd., New Territories Pump Industry Group Co., Ltd., Leo Group Zhejiang Pump Industry Co., Ltd., Shanghai Kaiquan Pump Industry (Group) Co., Ltd., Shanghai KSB Pump Co., Ltd., Hangzhou Alkaline Pump Co., Ltd., Chongqing Water Pump Factory Co., Ltd., Anhui Jiangnan Pump & Valve Group Co., Ltd., Zhejiang Branch Pump Industry Co., Ltd., Sinopec Guangzhou Engineering Co., Ltd., Guangzhou Xinheng Pump Manufacturing Co., Ltd., Chengdu Kaitian Electronics Co., Ltd. Co., Ltd., Hefei University of Technology, Xiamen Sanxing Electronics Co., Ltd., Guangdong Baijin New Energy Co., Ltd., Xiamen Keli Electronics Co., Ltd., Xiamen Kexin Electronics Co., Ltd., Xiamen Wanming Electronics Co., Ltd., CSSC Chongqing Intelligent Equipment Engineering Design Co., Ltd., Shenyang Water Pump graduate School. The main drafters of this standard. Wu Jianbo, Mo Yushi, Qu Jingtian, Ling Guirong, Wang Lin, Wang Yanhe, Pan Zaibing, Li Jinfu, Bai Xiaobang, Wu Tongmao, Chi Wu, Yang Chengjiong, Zhang Junhui, Jiang Jinsong, Wang Weijun, Shi Haihai, Long Xinhua, Pi Kunlin, Yi Zhonghui, Li Junxu, Huang Jingming, Dai Gaoyan, Liu Haichuan, Dong Qinmin. introduction The noise generated by the pump unit can pass through the pump body, drive system (e.g. motor, gearbox, coupling), piping system and all connecting parts. Radiation around. In the scene, due to the reverberation effect or external noise source radiation, the perceived noise may be significantly enhanced. The noise of the pump depends on the type of pump. It is very useful to understand the following noise characteristics of the pump. a) The noise of the pumping system (including pipelines); b) The noise of the pump unit, including the prime mover and transmission components, but not the noise of the piping system; c) The noise of the pump does not include the noise generated by the prime mover, transmission components and pipelines; d) The noise of each component obtained with specific requirements or with noise isolation devices. This standard specifies the measurement method for the noise emitted by the pump unit [b)] or pump [c)]. Use the sound power level of the machine and the emission of the relevant operating point The sound pressure level represents the emitted noise (see 6.2). This standard enables manufacturers to achieve the following goals. --- Demonstrate the effectiveness of equipment noise reduction; ---Mark the noise emission level of the equipment. This standard belongs to Class C standard in ISO 12100. This standard is particularly closely related to the following market participants involved in machinery safety. --- Equipment manufacturers (small, medium and large enterprises); ---Health and safety agencies (regulatory, accident prevention and market supervision agencies, etc.). The safety level achieved by the equipment specified by the above-mentioned participants through document means may affect the following personnel. --- Equipment users/employers (small, medium and large enterprises); --- Equipment users/employees (e.g. labor unions, organizations representing special needs groups); ---Service providers, such as repairs (small, medium and large enterprises); ---Consumers (in the case of consumers using the device). The above-mentioned participants may have participated in the drafting process of this standard, the equipment involved and the hazards, hazardous conditions or hazardous events generated The degree is within the scope of this standard. When the terms in the C-type standard are different from the terms in the A or B-type, the C-type standard terms can be used first. The involved pumps and their noise limits are the contents of this standard. Noise test methods for liquid pumps and pump units Level 2 and Level 3 1 Scope This standard specifies the relevant information for the effective implementation of the noise test of liquid pumps or pump units (see 4.1) and the air emitted by them under standard conditions. Noise measurement, labeling and verification methods, as well as liquid pump or pump unit noise measurement methods, test operation and equipment conditions. Noise emission characteristics include sound power level and emission sound pressure level at a specified point. The determination of these quantities can be used to. ---Mark the noise emission value; ---Control of noise sources in the design stage. The measurement of these quantities is also necessary to compare with the noise of liquid pumps on the market. The application of this standard can ensure the reproducibility of the measurement of air noise emission characteristics within a certain limit, which is determined by the Air Noise Measurement Institute. The accuracy level of the method is used to determine. The noise measurement methods covered by this standard include engineering method (level 2) and simplified method (level 3). This standard does not apply to structural and liquid-conducted liquid pump noise. Note. For the noise measurement of pumps or pump units specified in this standard, see EN809 A1. 2 Normative references The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 3767-2016 Acoustic sound pressure method to determine the sound power level and sound energy level of the noise source. Approximate free field above the reflective surface. Process method (ISO 3744.2010, IDT) GB/T 3768-2017 Acoustic sound pressure method is used to determine the sound power level and sound energy level of noise sources using the envelope measurement surface above the reflecting surface The simple method (ISO 3746.2010, IDT) GB/T 6881.2-2017 Acoustic sound pressure method to determine the sound power level and sound energy level of noise sources. Small movable sound sources in the reverberation field Engineering method hard wall test room comparison method (ISO 3743-1.2010, IDT) GB/T 33925.1-2017 General terms, definitions, quantities, characters and units for liquid pumps and their devices Part 1.Liquid pumps (ISO 17769-1.2012, IDT) GB/T 33925.2-2018 General terms, definitions, quantities, characters and units for liquid pumps and their devices Part 2.Pump system (ISO 17769-2.2012, IDT) ISO 3743-2.2018 Acoustic Sound Pressure Method for the Determination of Sound Power Level of Noise Sources Engineering Law No. 2 of Small Movable Sound Sources in Reverberation Fields Part. Dedicated Reverberation Laboratory Method (Acoustics-Determination of Sound Power Levels of Noise Sources Using soundpressure-Engineeringmethodsforsmal,movablesourcesinreverberantfields-Part 2.Meth- odsforspecialreverberationtestrooms) ISO 4871.1996 Acoustics-Declaration and Verifi- cationofnoiseemissionvaluesofmachineryandequipment) ISO 9614-1.1993 Acoustic Sound Intensity Method Determination of Sound Power Level of Noise Sources Part 1.Discrete Point Measurement Method (Acoustics-De- terminationofsoundpowerlevelsofnoisesourcesusingsoundintensity-Part 1.Measurementatdis- cretepoints) ......

Similar standards: JB/T 6879   GB/T 7782   JB/T 13977   GB/T 13930   GB/T 13929