GB 16154-2018English199 Add to Cart 3 days [Need to translate] General technical specification for civil water heating coal stove Valid GB 16154-2018
GB 16154-2005English399 Add to Cart 3 days [Need to translate] General technical specification of civil water heating coal stove Obsolete GB 16154-2005
GB/T 16154-1996English239 Add to Cart 2 days [Need to translate] General technical specification of domestic cooking-water heating coal stoves Obsolete GB/T 16154-1996

PDF Samples

Basic data

Standard ID GB 16154-2018 (GB16154-2018)
Description (Translated English) General technical specification for civil water heating coal stove
Sector / Industry National Standard
Classification of Chinese Standard Y71
Classification of International Standard 97.040.20
Word Count Estimation 10,130
Date of Issue 2018-07-13
Date of Implementation 2019-08-01
Issuing agency(ies) State Administration of Markets and China National Standardization Administration

Similar standards

GB 28379   QB/T 5418   GB 28378   GB/T 44180   GB/T 16155   

GB 16154-2018: General technical specification for civil water heating coal stove

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General technical specification for civil water heating coal stove ICS 97.040.20Y71 National Standards of People's Republic of China GB 16154-2018 replaces GB 16154-2005 General technical conditions for civil water heaters Published on.2018-07-13 2019-08-01 implementation State market supervision and administration China National Standardization Administration issued

Foreword

5.2.1, 5.2.2, 5.3, 5.4.7, 5.5 of this standard are mandatory, and the rest are recommended. This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB 16154-2005 "General technical conditions for civil water heaters." This standard is compared with GB 16154-2005, except The main technical changes outside the editorial revision are as follows. --- Removed the speed of fire (see 5.1.3.2 of the.2005 edition); --- Redefine the rated heat supply and thermal efficiency (see 3.4 and 3.5,.2005 and 3.5 and 3.6); --- Increased thermal efficiency and firepower intensity indicators (see 5.2.2 and 5.2.3,.2005 edition and 5.1.3.2); --- Increased the "air pollutant emission limit of furnaces" (see 5.3); --- Added content for safe use requirements (see 5.5). This standard is proposed and managed by the Ministry of Agriculture and Rural Affairs of the People's Republic of China. This standard was drafted. China Rural Energy Industry Association, Beijing Zhongyan Environmental Energy Technology Testing Center, Hebei Xinhua New Boiler Manufacturing Co., Ltd., Shandong Duole Heating Equipment Co., Ltd., Beijing Laowan Biomass Energy Technology Co., Ltd., Shijiazhuang City Chunyan Heating Equipment Co., Ltd., Hebei Guanglei Furnace Co., Ltd., Gaobeidian City Qinqin Heating Equipment Factory, Renqiu City Innovation Heating Equipment Co., Ltd., Zhangzhou Fangzheng Furnace Co., Ltd. The main drafters of this standard. Jia Zhenhang, Hao Fangzhou, Yang Mingzhen, Liu Wenyi, Sun Tiezhu, Xing Lili, Li Fenglin, Kang Tieliang, Zhang Jiayi, Liu Huqun, Guan Zhiling. The previous versions of the standards replaced by this standard are. ---GB 16154-1996, GB 16154-2005. General technical conditions for civil water heaters

1 Scope

This standard specifies the model representation method, technical requirements, test methods, inspection rules, etc. of the civil water heater. This standard is applicable to clean coal such as briquette, washing coal, etc., with rated heat supply less than 50kW, rated working pressure as normal pressure, and circulation. The system is not more than 10m in height, and the outlet water temperature is not higher than 85°C. The civil water heating coal stove with cooking function can refer to carried out.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 567 rupture disc safety device GB/T 16155 Civil water heating coal stove performance test method NY/T 1703 Civil Water Heater Heating System Installation and Acceptance Specifications

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 3.2 Protect and secure the outer casing of components such as hot water jackets, furnace tiles and insulation materials. 3.3 A component made of refractory material for holding coal and forming a combustion chamber. 3.4 3.5 3.6 3.7

4 Model representation

4.1 Representation in uppercase Chinese Pinyin letters and Arabic numerals. 4.2 The model consists of five parts. a) The first part indicates the main use of the civil water heater; b) The second part indicates the type of fuel; c) The third part indicates the rated heat supply; d) The fourth part indicates the improvement of the serial number; e) The fifth part indicates that the furnace has an anecdote function. 4.3 The symbols and meanings of the various components of the model are as follows. a) Part 1. Use the pinyin letter N to indicate. N--- indicates the civil water heater. b) Part II; expressed in Chinese Pinyin letters F or Q. F--- indicates burning honeycomb coal; Q--- means burning other briquette or clean coal. c) Part III. The nominal heat supply is expressed in Arabic numerals, with one digit after the decimal point. d) Part IV. The improved serial number of the stove is indicated by Roman numerals. Add a short "-" between the third and fourth parts. e) Part 5. Use the Pinyin letter C to indicate an anecdote function. Example. N indicates the civil water heater Q means burning other briquette or clean coal 12 indicates that the rated heat supply is  12kW -III indicates the improved serial number of the stove C indicates that the furnace has an anecdote function It indicates that the stove is a plumbing type, burning other briquette or clean coal, the rated heat supply is 12kW, and the improved serial number is type III, which has an anecdote function.

5 Technical requirements

5.1 Basic requirements 5.1.1 Structure The structure of the stove should be reasonable in design, good in sealing, easy to operate, safe and reliable. 5.1.2 Appearance Beautiful appearance, smooth surface, no burrs. 5.1.3 Auxiliary accessories The auxiliary machine and accessories of the stove should meet the corresponding national product standards. 5.1.4 Safety device 5.1.4.1 The furnace should be equipped with rupture discs. 5.1.4.2 The bursting pressure should not exceed 0.2 MPa, and the inner diameter of the discharge hole should not be less than 25 mm. 5.1.4.3 The rupture discs shall comply with the provisions of GB 567. 5.2 Thermal performance indicators 5.2.1 The rated heat supply is not less than the nominal value. 5.2.2 Thermal efficiency η. η ≥ 65%. 5.2.3 If there is an anecdote function, its cooking intensity Pc. bituminous coal Pc ≥ 1.5kW, anthracite, briquette Pc ≥ 1.0kW. 5.2.4 The fire sealing capacity should be greater than 10h. 5.3 Furnace air pollutant emission limit The air pollutant emission limits of the stove are shown in Table 1. Table 1 Limits of atmospheric pollutant emission concentration of stoves Flue gas pollutant emission index Particulate matter/(mg/m3) ≤ 50 Sulfur dioxide/(mg/m3) ≤ 100 NOx/(mg/m3) ≤ 150 Carbon monoxide /% ≤ 0.2 Smoke blackness (Lingeman blackness)/grade ≤ 1 5.4 Manufacturing requirements 5.4.1 Casting parts should be smooth and free from defects such as cracks, pores and blisters. 5.4.2 Welded parts shall be flat and uniform, without defects such as burn through, slag inclusions, pores, and incomplete penetration. 5.4.3 Stamping parts shall be free from defects such as cracks, wrinkles, flash edges and burrs. 5.4.4 The surface of sheet metal parts should be flat and free of defects such as cracks, wrinkles, bumps, etc. The machined surface should not have defects such as smashing, bumping and scratching. 5.4.5 The riveted parts should be firm and the rivets should be free from looseness and skew. 5.4.6 The outer wall surface of the furnace should be treated with anti-rust treatment. The anti-rust layer should be waterproof and not easy to fall off. 5.4.7 When using hot cast iron, the wall thickness should not be less than 4mm; when using carbon steel, the nominal thickness of the heated surface steel should not be small. At 3 mm, the nominal thickness of the non-heated steel sheet shall not be less than 2 mm. 5.4.8 The inside of the hot water jacket should ensure sufficient circulating water circulation cross-sectional area, and the width of the hot water jacket interlayer (between the inner and outer walls of the hot water jacket) The clearance should be in accordance with Table 2. Table 2 Heat sink jacket interlayer width Rated heat supply kW Water jacket interlayer width Mm ≤5 ≥8 >5~10 ≥12 >10~20 ≥15 >20~30 ≥20 >30 ≥25 5.4.9 The furnace tile (biliary) shall be resistant to high temperature and without defects, and its size, shape and thickness shall conform to the design requirements. 5.4.10 Insulation and insulation materials shall comply with national standards. 5.4.11 Each stove shall be subjected to a hydrostatic test in accordance with 6.4 and shall be free from leakage. 5.4.12 The inlet and outlet pipes of the stove are shown in Table 3. Table 3 Inlet and outlet pipe diameter Rated heat supply kW Inlet and outlet pipe diameter Mm ≤5 20 >5~10 25~32 >10~50 32~50 5.5 Safe use requirements 5.5.1 Civil water heaters are strictly prohibited from being installed in the bedroom. 5.5.2 The civil water heater should be equipped with a chimney and open to the outside, and the indoor air should be kept open. It is forbidden to install any form in the flue. Baffle. 5.5.3 The water level of the expansion tank should be no less than one third of its height. When the water volume is insufficient, it should be replenished in time. 5.5.4 Heating circulating water should not be used for other purposes. 5.5.5 It is strictly forbidden to start the ignition when the civil water heater is frozen. 5.5.6 Heating system installation is carried out in accordance with NY/T 1703. 5.5.7 The civil water heaters equipped with electrical installations shall have safe electrical measures.

6 Test methods

6.1 Technical requirements 5.1 and 5.4 use measuring tools and visual inspection methods. 6.2 Technical requirements 5.2 and 5.3 are c......