YY/T 1536-2017: Catheters other than intravascular catheters - Standard test model for evaluating the surface sliding performance
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 1536-2017159 Add to Cart 3 days Catheters other than intravascular catheters - Standard test model for evaluating the surface sliding performance Valid

Similar standards

YY/T 1550.2   YY/T 1556   YY/T 1510   YY/T 1148   YY 1001   

Basic data

Standard ID: YY/T 1536-2017 (YY/T1536-2017)
Description (Translated English): Catheters other than intravascular catheters - Standard test model for evaluating the surface sliding performance
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C31
Classification of International Standard: 11.040.20
Word Count Estimation: 8,877
Date of Issue: 2017-03-28
Date of Implementation: 2018-04-01
Regulation (derived from): China Food & Drug Administration Announcement 2017 No. 38
Issuing agency(ies): State Food and Drug Administration

YY/T 1536-2017: Catheters other than intravascular catheters - Standard test model for evaluating the surface sliding performance


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Catheters other than intravascular catheters-Standard test model for evaluating the surface sliding performance ICS 11.040.20 C31 People's Republic of China pharmaceutical industry standards Non-intravascular catheters Standard Test Model for Evaluation of Surface Slip Properties 2017-03-28 Posted 2018-04-01 implementation State Food and Drug Administration released

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard by the National Medical Devices Standardization Technical Committee (SAC/TC106) and focal point. The main drafting units of this standard. Shandong Hanson testing technology development center. Participated in the drafting of this standard. Shandong more than 100 Medical Devices Co., Ltd.. The main drafters of this standard. Yu Xiaohui, Sun Haipeng, Zhang Haijun.

Introduction

One-time use of non-intravascular catheters is widely used clinically. In order to reduce the friction of the catheter into the body and reduce the suffering of patients, To achieve lubrication, prevent infection and other effects, usually in the catheter surface coating treatment. The coated catheters will generally have their own distinct sound Said the most common is claimed to be "super slippery." How to evaluate the one-time use of non-intravascular catheters that claim to be "ultra-slip" Have not solved the problem. This standard gives a standard test model for evaluating the sliding properties of disposable non-intravascular catheters, but does not provide for specific Evaluation method. When using this model to establish the evaluation method, it is necessary to confirm the evaluation method according to the product characteristics and specific applications to obtain the subjects Evaluation results of the school. Non-intravascular catheters Standard Test Model for Evaluation of Surface Slip Properties

1 Scope

This standard specifies the evaluation of one-time use of non-intravascular catheters (hereinafter referred to as the catheter) the standard sliding surface test model and model application. The model specified in this standard is suitable for evaluation of catheters entering the body with a lubricious coating or purported to be ultra-smooth (low resistance). Note. Appendix A gives an example of a method for assessing catheter gliding performance using this model.

2 test model

2.1 test device 2.1.1 catheter sliding performance test device shown in Figure 1. Size .mm a) Clamping system b) Key dimensions of sliding clamps and clamps c) Chute and cylinder installation d) test device assembly Figure 1 catheter sliding performance test device schematic
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1536-2017_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1536-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1536-2017_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1536-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.