TSG ZB001-2008 PDF EnglishUS$105.00 · In stock · Download in 9 seconds
TSG ZB001-2008: Safety Technical Regulation for Oil and Gas Burners Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Obsolete
TSG ZB001-2008: Safety Technical Regulation for Oil and Gas Burners---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/TSGZB001-2008TSG Safety Technical Code of Special Equipment Safety Technical Regulation for Oil and Gas Burners Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China January 08, 2008 Table of ContentsChapter 1 General Provisions... 5 Chapter 2 Structure and Design... 7 Chapter 3 Safety and Control Devices... 10 Chapter 4 Installation and System... 15 Chapter 5 Operation and Maintenance... 17 Chapter 6 Technical Documents and Nameplates... 19 Chapter 7 Supplementary Provisions... 21 Appendix A Definition for Models of Oil and Gas Burners... 22 Appendix B Requirements for the Arrangement of Safety Shut-off Valve of the Pressure Atomizing Oil Burner... 23 Appendix C Requirements for the Safety Time and Maximum Permissible Starting Thermal Power of the Oil Burner... 27 Appendix D Terms... 28 Attachment 1 "Safety Technical Regulation for Oil and Gas Burners" (TSG ZB 001-2008) No.1 Amendment... 31 Safety Technical Regulation for Oil and Gas Burners Chapter 1 General Provisions Article 1 This Regulation is formulated to ensure the safe operation of oil (gas) burner (hereinafter referred to as "the burner"), avoid and reduce accidents from oil and gas equipment, ensure life safety and reduce property loss. Article 2 This Regulation is applicable to burners for various oil and gas boilers, and burners for other purposes may refer to this Regulation. Article 3 This Regulation specifies the requirements for the burner with regard to its structure and design, safety and control devices, installation and system, operation and maintenance, technical documents and nameplate etc.. The dual fuel burner shall simultaneously meet the requirements for oil burner and gas burner as specified in this Regulation. Chapter 2 Structure and Design Article 7 Burners shall be such designed to meet the following requirements. (1) Performances like the output thermal power of the burner shall be able to reach those specified; (2) Each part’s structure and its dimension shall be such designed to be able to ensure the reliable and economic operation of burners while the safety of operating personnel is ensured, and phenomena endangering the equipment safety, like structural instability, deformation or cracking, shall be avoided; (3) For burners equipped with flame observation aperture, accessories of such observation aperture shall be possessed of adequate strength and be sealed tightly to avoid flaming out or flue gas leaking out; (4) Moving parts (fan and belt gear etc.) of burners must be designed with protective devices to prevent foreign matters in influencing the normal and safe operation of equipment, and the burner fan inlet shall be equipped with reliable protective net enclosures; (5) Air control devices shall be provided, and if the damper regulator is arranged for them, it shall be clearly indicated for its position; (6) For the multi-stage control or continuous control burner, its air and oil (gas) control devices may be linked mechanically, electrically or in other modes. Chapter 3 Safety and Control Devices Article 13 Burners shall be equipped with ignition devices and able to ensure the safe ignition of ignition burner or main burner. Article 14 The burner shall be equipped with flame monitoring device which shall meet the following requirements. Chapter 4 Installation and System Article 33 The burner must be installed by professional personnel in strict accordance with technical documents provided by the manufacturing organization. The external wiring must be constructed in strict accordance with the wiring diagram provided by the manufacturing organization. Article 34 The burner and its parts shall be transported and installed steadily to avoid impact and crash. Each part of the burner shall be installed and fixed to the proper position in correct method, and able to maintain at the original position after being dismantled and re-assembled. Article 35 The oil pump device (including oil pump, filter, motor and pressure control valve) and its fuel oil pipeline shall be provided with the following safety measures. Chapter 5 Operation and Maintenance Article 43 Under the supply of specified fuel, the burner shall be able to operate normally within the operating range provided by the manufacturing organization. Article 44 At the starting of the burner, the continuous ignition times shall not exceed 2, and reasons shall be found out at the failure of ignition and the burner shall be re-started after being adjusted properly. Article 45 The flame stability shall conform to the following requirements. Chapter 6 Technical Documents and Nameplates Article 54 At the delivery of burner products, the following technical documents for production (expressed in Chinese or English and adopting international units) shall at least be accompanied. Chapter 7 Supplementary Provisions Article 57 Implications of terms used in this Regulation are detailed in Appendix D. Article 58 AQSIQ is responsible for the interpretation of this Regulation. Article 59 This Regulation shall be implemented from April 30, 2008.Appendix ADefinition for Models of Oil and Gas Burners A1 Basic definition for models Models of oil and gas burners are for numbering of burners, with different types, structural dimensions and performance parameters, manufactured by the burner manufacturing organization. The burner model will change if any of the followings changes.Appendix BRequirements for the Arrangement of Safety Shut-off Valve of the Pressure Atomizing Oil Burner B1 Arrangement of the safety shut-off valve for single-stage oil burner Figure B-1 is applicable to the oil burner with the rated oil level less than or equal to 100kg/h. TSG ZB001-2008 TSG Safety Technical Code of Special Equipment Safety Technical Regulation for Oil and Gas Burners Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China January 08, 2008Table of ContentsChapter 1 General Provisions... 5 Chapter 2 Structure and Design... 7 Chapter 3 Safety and Control Devices... 10 Chapter 4 Installation and System... 15 Chapter 5 Operation and Maintenance... 17 Chapter 6 Technical Documents and Nameplates... 19 Chapter 7 Supplementary Provisions... 21 Appendix A Definition for Models of Oil and Gas Burners... 22 Appendix B Requirements for the Arrangement of Safety Shut-off Valve of the Pressure Atomizing Oil Burner... 23 Appendix C Requirements for the Safety Time and Maximum Permissible Starting Thermal Power of the Oil Burner... 27 Appendix D Terms... 28 Attachment 1 "Safety Technical Regulation for Oil and Gas Burners" (TSG ZB 001-2008) No.1 Amendment... 31 Safety Technical Regulation for Oil and Gas Burners Chapter 1 General Provisions Article 1 This Regulation is formulated to ensure the safe operation of oil (gas) burner (hereinafter referred to as "the burner"), avoid and reduce accidents from oil and gas equipment, ensure life safety and reduce property loss. Article 2 This Regulation is applicable to burners for various oil and gas boilers, and burners for other purposes may refer to this Regulation. Article 3 This Regulation specifies the requirements for the burner with regard to its structure and design, safety and control devices, installation and system, operation and maintenance, technical documents and nameplate etc.. The dual fuel burner shall simultaneously meet the requirements for oil burner and gas burner as specified in this Regulation. Chapter 2 Structure and Design Article 7 Burners shall be such designed to meet the following requirements. (1) Performances like the output thermal power of the burner shall be able to reach those specified; (2) Each part’s structure and its dimension shall be such designed to be able to ensure the reliable and economic operation of burners while the safety of operating personnel is ensured, and phenomena endangering the equipment safety, like structural instability, deformation or cracking, shall be avoided; (3) For burners equipped with flame observation aperture, accessories of such observation aperture shall be possessed of adequate strength and be sealed tightly to avoid flaming out or flue gas leaking out; (4) Moving parts (fan and belt gear etc.) of burners must be designed with protective devices to prevent foreign matters in influencing the normal and safe operation of equipment, and the burner fan inlet shall be equipped with reliable protective net enclosures; (5) Air control devices shall be provided, and if the damper regulator is arranged for them, it shall be clearly indicated for its position; (6) For the multi-stage control or continuous control burner, its air and oil (gas) control devices may be linked mechanically, electrically or in other modes. Chapter 3 Safety and Control Devices Article 13 Burners shall be equipped with ignition devices and able to ensure the safe ignition of ignition burner or main burner. Article 14 The burner shall be equipped with flame monitoring device which shall meet the following requirements. Chapter 4 Installation and System Article 33 The burner must be installed by professional personnel in strict accordance with technical documents provided by the manufacturing organization. The external wiring must be constructed in strict accordance with the wiring diagram provided by the manufacturing organization. Article 34 The burner and its parts shall be transported and installed steadily to avoid impact and crash. Each part of the burner shall be installed and fixed to the proper position in correct method, and able to maintain at the original position after being dismantled and re-assembled. Article 35 The oil pump device (including oil pump, filter, motor and pressure control valve) and its fuel oil pipeline shall be provided with the following safety measures. Chapter 5 Operation and Maintenance Article 43 Under the supply of specified fuel, the burner shall be able to operate normally within the operating range provided by the manufacturing organization. Article 44 At the starting of the burner, the continuous ignition times shall not exceed 2, and reasons shall be found out at the failure of ignition and the burner shall be re-started after being adjusted properly. Article 45 The flame stability shall conform to the following requirements. Chapter 6 Technical Documents and Nameplates Article 54 At the delivery of burner products, the following technical documents for production (expressed in Chinese or English and adopting international units) shall at least be accompanied. Chapter 7 Supplementary Provisions Article 57 Implications of terms used in this Regulation are detailed in Appendix D. Article 58 AQSIQ is responsible for the interpretation of this Regulation. Article 59 This Regulation shall be implemented from April 30, 2008.Appendix ADefinition for Models of Oil and Gas Burners A1 Basic definition for models Models of oil and gas burners are for numbering of burners, with different types, structural dimensions and performance parameters, manufactured by the burner manufacturing organization. The burner model will change if any of the followings changes.Appendix BRequirements for the Arrangement of Safety Shut-off Valve of the Pressure Atomizing Oil Burner B1 Arrangement of the safety shut-off valve for single-stage oil burner Figure B-1 is applicable to the oil burner with the rated oil level less than or equal to 100kg/h. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of TSG ZB001-2008 be delivered?Answer: The full copy PDF of English version of TSG ZB001-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of TSG ZB001-2008_English with my colleagues?Answer: Yes. The purchased PDF of TSG ZB001-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- TSG ZB001-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of TSG ZB001-2008?A step-by-step guide to download PDF of TSG ZB001-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "TSG ZB001-2008". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |