SN/T 0481.7-2007: Inspection of bauxite for import and export - Determination of Fe2O3, TiO2, SiO2, CaO, MgO content - Inductively coupled plasma atomic emission spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
SN/T 0481.7-2007110 Add to Cart Auto, 9 seconds. Inspection of bauxite for import and export - Determination of Fe2O3, TiO2, SiO2, CaO, MgO content - Inductively coupled plasma atomic emission spectrometry Valid

Similar standards

SN/T 3321.2   SN/T 3321.1   SN/T 0481.5   

SN/T 0481.7-2007: Inspection of bauxite for import and export - Determination of Fe2O3, TiO2, SiO2, CaO, MgO content - Inductively coupled plasma atomic emission spectrometry


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/SNT0481.7-2007
ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Inspection of bauxite for import and export - Determination of Fe2O3, TiO2, SiO2, CaO, MgO content - Inductively coupled plasma atomic emission spectrometry ISSUED ON: APRIL 06, 2007 IMPLEMENTED ON: OCTOBER 16, 2007 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Method summary ... 4 4 Reagents ... 5 5 Instruments and equipment ... 6 6 Sampling and sample preparation ... 6 7 Specimen preparation ... 7 8 Analysis steps ... 7 9 Calculation of analysis result ... 8 10 Precision ... 9 Annex A (informative) Working conditions and detection limit of instrument ... 10 Inspection of bauxite for import and export - Determination of Fe2O3, TiO2, SiO2, CaO, MgO content - Inductively coupled plasma atomic emission spectrometry

1 Scope

This Part of SN/T 0481 specifies inductively coupled plasma atomic emission spectrometry (hereinafter referred as ICP-AES), the method to determine ferric oxide (Fe2O3), titanium dioxide (TiO2), silicon dioxide (SiO2), calcium oxide (CaO), magnesium oxide (MgO) content in bauxite. This Part is applicable to the determination of Fe2O3, TiO2, SiO2, CaO, MgO content in bauxite. See Table 1 for the determination range of each element.

2 Normative references

The provisions in following documents become the provisions of this Part of SN/T 0481 through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Part, however, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 2007 (all parts), General rules for the sampling and sample preparation of minerals in bulk

3 Method summary

The specimen uses lithium tetraborate as the flux. After it is melted at a high temperature, use hydrochloric acid to extract. After the volume is set constant, use ICP- AES instrument to determine the emission spectrum intensity of the test element in the test solution. Find corresponding concentration from the working curve. Calculate its content.

4 Reagents

Unless otherwise specified, it shall only use the confirmed analytically-pure reagents and distilled water or equivalent-pure water in the analysis. 4.1 Graphite powder: Powder, 100 meshes, carbon content ≥ 98.5%. 4.2 Argon: ≥99.99%. 4.3 Hydrogen peroxide (ρ=1.10g/mL). 4.4 Hydrochloric acid (ρ=1.19g/mL). 4.5 Hydrochloric acid solution (1+9). 4.6 Hydrochloric acid solution (1+3). 4.7 Lithium tetraborate. 4.8 Lithium tetraborate solution (10g/L): Weigh 1.0g of lithium tetraborate (4.7). Add 50mL of hydrochloric acid solution (4.5). Slightly heat it to make it dissolved. Use water to set the volume constant into a 100mL volumetric flask. Mix well for use. 4.9 Aluminum standard solution (10mg/mL): Accurately weigh 1.0000g of high purity aluminum (99.99%) into a 200mL beaker. Add 40mL of hydrochloric acid solution (4.6). Boil it till it is clear. If it is insoluble, it may add a certain amount of hydrogen peroxide (4.3). Cool down. Transfer it into a 100mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 10mg of aluminum. 4.10 Iron, titanium, calcium, and magnesium standard stock solutions (1mg/mL). 4.11 Silicon standard stock solution (0.5mg/mL). 4.12 Mixed standard solution: Respectively pipette 40.00mL of silicon standard stock solution (4.9.3); 15.00mL of iron, titanium standard stock solutions (4.9.2) each; 5.00mL of calcium, magnesium standard stock solutions (4.9.2) each -- into 100mL volumetric flasks. Then add 10.00mL of concentrated hydrochloric acid (4.4). Set the volume constant. Mix well for use. See Table 2 of the content of each element. tweezers to take the molten beads out. Use a brush to remove the graphite powder attached to the surface. Put the molten beads into the beaker. Add 40mL of hydrochloric acid solution (4.6). Place it in the (55 ± 5)°C constant temperature water bath oscillator. Immerse till the molten beads are completely dissolved. Filter into a 250mL volumetric flask. Set the volume constant. Mix well for ICP-AES determination. 8.4 Spectral measurement 8.4.1 Instrument optimization Start the ICP-AES instrument. Adjust the working conditions and measurement parameters of the instrument to the best state (see Annex A). 8.4.2 Drawing of working curve Introduce the standard solution series (8.3.1) into the plasma in sequence. Measure the spectral signal intensity of each analysis line. Use the strength as Y-axis, the concentration (µg/mL) of each test element in each standard solution as X-axis, to obtain the working curve of each element. Perform linear regression. Calculate the correlation coefficient. The correlation coefficient shall meet the requirements of 5.4.4. 8.4.3 Determination of test solution Introduce the blank solution (8.2) and the test material solution (8.3.2) into the plasma. Respectively measure the spectral intensity of each test element. According to the working curve, obtain the concentration of each corresponding component. If the number of samples is large, the standard sample can be inserted into the sample measurement gap as a control sample, so as to control the accuracy of the analysis result.

9 Calculation of analysis result

Calculate the content of oxides of each element according to formula (1), expressed in mass fraction: Where, w1 - The mass fraction of the oxides of each test element, %; c - The concentration of each test element in the test material solution, in micrograms per milliliter (µg/mL); c0 - The concentration of each test element in the blank solution, in micrograms per milliliter (µg/mL); ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of SN/T 0481.7-2007 be delivered?Answer: The full copy PDF of English version of SN/T 0481.7-2007 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of SN/T 0481.7-2007_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 0481.7-2007_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- SN/T 0481.7-2007 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of SN/T 0481.7-2007?

A step-by-step guide to download PDF of SN/T 0481.7-2007_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "SN/T 0481.7-2007".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9