SN/T 3321.2-2013 PDF EnglishUS$140.00 · In stock · Download in 9 seconds
SN/T 3321.2-2013: Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsSN/T 3321.2-2013: Limestone and dolomite. Part 2: Determination of carbon and sulfur content. High frequency combustion with infrared absorption method---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/SNT3321.2-2013 SN ENTRY AND EXIT INSPECTION AND QUARANTINE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Limestone and dolomite - Part 2: Determination of carbon and sulfur content - High frequency combustion with infrared absorption method ISSUED ON: AUGUST 30, 2013 IMPLEMENTED ON: MARCH 01, 2014 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC Table of ContentsForeword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Method summary ... 4 4 Reagents and materials ... 5 5 Instruments and equipment... 5 6 Preparation of specimen ... 5 7 Analytical procedures ... 5 8 Result calculation ... 7 9 Result representation ... 7 10 Precision ... 7 Limestone and dolomite - Part 2: Determination of carbon and sulfur content - High frequency combustion with infrared absorption method1 ScopeThis Part of SN/T 3321 specifies the high-frequency combustion with infrared absorption method, for the determination of carbon and sulfur content in limestone and dolomite. This Part applies to the determination of carbon and sulfur content in limestone and dolomite, in which the determination range (mass fraction) of carbon content is 10% ~ 15%, the determination range (mass fraction) of sulfur content is 0.02% ~ 0.2%.2 Normative referencesThe following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB/T 2007.2 General rules for the sampling and sample preparation of minerals in bulk - Manual method of sample preparation3 Method summaryThe specimen is heated and burned in the oxygen flow of the high-frequency induction furnace; the generated carbon dioxide (or carbon monoxide) and sulfur dioxide are carried by the oxygen, to the measuring chamber of the infrared analyzer. The carbon dioxide (or carbon monoxide) and sulfur dioxide absorb infrared energy of a certain wavelength. The absorption energy is proportional to its concentration; then the carbon and sulfur content can be measured, according to the change of the energy received by the detector. concentrations of oxygen can cause fires, in confined spaces. 7.1 Instrument debugging Assemble the instrument, according to the manufacturer's instructions. Prepare it for operation. Check the air tightness of the combustion unit and the measuring unit. Before calibrating and measuring specimens, it is necessary to check and debug the instrument, to ensure that the instrument is in a normal and stable working state; meanwhile determine the best analysis conditions. 7.2 Blank test A blank test is performed along with the specimen analysis. According to the analysis method of the specimen, add the corresponding pure iron flux and tungsten particles. Carry out at least three blank tests. Blanks are subtracted from subsequent specimen measurements. 7.3 Calibration 7.3.1 Carbon calibration with calcium carbonate purity standards Weigh 0.05 g of calcium carbonate purity standard (4.3), accurate to 0.0001 g. Place it in a crucible (5.2), that has been burned and covered with 0.2 g of pure iron flux (4.1). Then cover 1.2 g of tungsten particles (4.2). Make at least three measurements. Perform linear adjustment of the system. 7.3.2 Sulfur calibration with limestone and dolomite standards According to the sulfur content of the specimen to be tested, weigh 0.2 g of the appropriate standard (4.4), accurate to 0.0001 g. Place it in a crucible (5.2), that was burnt and covered with 0.2 g of pure iron flux (4.1). Then cover 0.2 g of pure iron flux (4.1) AND 1.2 g of tungsten particles (4.2). Make at least three measurements. Perform linear adjustment of the system. 7.4 Analysis of specimen 7.4.1 Determination of carbon content Weigh 0.05 g of the specimen, accurate to 0.0001 g. Place it in a crucible (5.2), that has been burned and covered with 0.2 g of pure iron flux (4.1). Then cover 1.2 g of tungsten particles (4.2). Use the same test conditions, procedures, operations as the measurement of standard sample, to make measurement. 7.4.2 Determination of sulfur content Weigh 0.2 g of the specimen, accurate to 0.0001 g. Place it in a crucible (5.2), that has been burned and covered with 0.2 g of pure iron flux (4.1). Then cover 0.2 g of pure iron flux (4.1) AND 1.2 g of tungsten particles (4.2). Use the same ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of SN/T 3321.2-2013 be delivered?Answer: The full copy PDF of English version of SN/T 3321.2-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of SN/T 3321.2-2013_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3321.2-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- SN/T 3321.2-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of SN/T 3321.2-2013?A step-by-step guide to download PDF of SN/T 3321.2-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "SN/T 3321.2-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |